Cargando…

Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection

Based on cytochrome c-multiwalled carbon nanotubes (Cyt c-MWCNTs) and cobalt metal–organic frameworks/gold nanoparticles (Co-MOFs/AuNPs), an electrochemical biosensor was proposed for the detection of nitrite. Herein, Co-MOFs and AuNPs were immobilized on gold electrodes via surface layer assembly....

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Shan, Lu, Ming, Wang, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690941/
https://www.ncbi.nlm.nih.gov/pubmed/35423011
http://dx.doi.org/10.1039/d0ra09551f
_version_ 1784618709026865152
author Huang, Shan
Lu, Ming
Wang, Lei
author_facet Huang, Shan
Lu, Ming
Wang, Lei
author_sort Huang, Shan
collection PubMed
description Based on cytochrome c-multiwalled carbon nanotubes (Cyt c-MWCNTs) and cobalt metal–organic frameworks/gold nanoparticles (Co-MOFs/AuNPs), an electrochemical biosensor was proposed for the detection of nitrite. Herein, Co-MOFs and AuNPs were immobilized on gold electrodes via surface layer assembly. Their advantages including large surface area and high conductivity provided an excellent platform for the immobilization of Cyt c-MWCNTs. Cyt c-MWCNTs were prepared via electrostatic adsorption and possessed good biocompatibility and superior electrocatalytic activity towards nitrite. Notably, MWCNTs and AuNPs could provide a good microenvironment for the electron transfer of Cyt c, which further significantly promoted the dispersion of MWCNTs. All of the above features led to outstanding electrochemical performance and achieved signal amplification for nitrite detection. Therefore, the biosensor displayed a linear range from 0.005 μmol L(−1) to 1000 μmol L(−1) with a detection limit of 0.0044 μmol L(−1) for nitrite detection. In addition, the designed biosensor exhibited excellent selectivity and could be applied in real samples.
format Online
Article
Text
id pubmed-8690941
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-86909412022-04-13 Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection Huang, Shan Lu, Ming Wang, Lei RSC Adv Chemistry Based on cytochrome c-multiwalled carbon nanotubes (Cyt c-MWCNTs) and cobalt metal–organic frameworks/gold nanoparticles (Co-MOFs/AuNPs), an electrochemical biosensor was proposed for the detection of nitrite. Herein, Co-MOFs and AuNPs were immobilized on gold electrodes via surface layer assembly. Their advantages including large surface area and high conductivity provided an excellent platform for the immobilization of Cyt c-MWCNTs. Cyt c-MWCNTs were prepared via electrostatic adsorption and possessed good biocompatibility and superior electrocatalytic activity towards nitrite. Notably, MWCNTs and AuNPs could provide a good microenvironment for the electron transfer of Cyt c, which further significantly promoted the dispersion of MWCNTs. All of the above features led to outstanding electrochemical performance and achieved signal amplification for nitrite detection. Therefore, the biosensor displayed a linear range from 0.005 μmol L(−1) to 1000 μmol L(−1) with a detection limit of 0.0044 μmol L(−1) for nitrite detection. In addition, the designed biosensor exhibited excellent selectivity and could be applied in real samples. The Royal Society of Chemistry 2020-12-23 /pmc/articles/PMC8690941/ /pubmed/35423011 http://dx.doi.org/10.1039/d0ra09551f Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Huang, Shan
Lu, Ming
Wang, Lei
Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title_full Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title_fullStr Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title_full_unstemmed Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title_short Cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
title_sort cytochrome c-multiwalled carbon nanotube and cobalt metal organic framework/gold nanoparticle immobilized electrochemical biosensor for nitrite detection
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690941/
https://www.ncbi.nlm.nih.gov/pubmed/35423011
http://dx.doi.org/10.1039/d0ra09551f
work_keys_str_mv AT huangshan cytochromecmultiwalledcarbonnanotubeandcobaltmetalorganicframeworkgoldnanoparticleimmobilizedelectrochemicalbiosensorfornitritedetection
AT luming cytochromecmultiwalledcarbonnanotubeandcobaltmetalorganicframeworkgoldnanoparticleimmobilizedelectrochemicalbiosensorfornitritedetection
AT wanglei cytochromecmultiwalledcarbonnanotubeandcobaltmetalorganicframeworkgoldnanoparticleimmobilizedelectrochemicalbiosensorfornitritedetection