Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study

BACKGROUND: Bone and Site Hold Tendon Inside (BASHTI) technique is an organic implant-less technique for anterior cruciate ligament (ACL) reconstruction with some clinical advantages, such as speeding up the healing process, over implantable techniques. The study aims to compare the mechanical prope...

Descripción completa

Detalles Bibliográficos
Autores principales: Borjali, Amirhossein, Nourani, Amir, Moeinnia, Hadi, Mohseni, Mahdi, Korani, Hossein, Ghias, Narges, Chizari, Mahmoud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691038/
https://www.ncbi.nlm.nih.gov/pubmed/34930185
http://dx.doi.org/10.1186/s12891-021-04788-3
_version_ 1784618729568468992
author Borjali, Amirhossein
Nourani, Amir
Moeinnia, Hadi
Mohseni, Mahdi
Korani, Hossein
Ghias, Narges
Chizari, Mahmoud
author_facet Borjali, Amirhossein
Nourani, Amir
Moeinnia, Hadi
Mohseni, Mahdi
Korani, Hossein
Ghias, Narges
Chizari, Mahmoud
author_sort Borjali, Amirhossein
collection PubMed
description BACKGROUND: Bone and Site Hold Tendon Inside (BASHTI) technique is an organic implant-less technique for anterior cruciate ligament (ACL) reconstruction with some clinical advantages, such as speeding up the healing process, over implantable techniques. The study aims to compare the mechanical properties of BASHTI technique with the conventional interference screw technique. METHODS: To investigate the mechanical properties, 20 in-vitro experimental tests were conducted. Synthetic dummy bone, along with fresh digital bovine tendons, as a graft, were used for experiments. Three loading steps were applied to all specimens, including a preconditioning, a main cyclic, and a pull-out loading. RESULTS: The mechanical characters of an interference screw technique using an 8 mm tendon diameter, including fixation strength, average cyclic stiffness (ACS), and average pull-out stiffness (APS) were found to be 439 ± 132 N, 10.3 ± 5.3 kN/mm, and 109 ± 40 N/mm, respectively. In the case of an interference screw using a 9 mm tendon, the fixation strength, ACS, and APS were obtained 549 ± 87 N, 10.3 ± 4.7 kN/mm, and 91 ± 13 N/mm, respectively. In parallel, the fixation strength, APS, and ACS of BASHTI technique using an 8 mm tendon were 360 ± 123 N, 3.3 ± 0.6 kN/mm, and 79 ± 27 N/mm, respectively, while, for 9 mm tendon 278 ± 103 N, 2.4 ± 1.2 kN/mm, and 111 ± 40 N/mm, were reported for fixation strength, APS, and ACS respectively when BASHTI technique was used. CONCLUSION: About 50% of interference screw samples showed superior mechanical properties compared to BASHTI technique, but in another half of the samples, the differences were not significant (N.S.). However, due to organic advantages of BASHTI technique and lower cost, it could be used as a substitute for interference screw technique, especially where fast recovery is expected.
format Online
Article
Text
id pubmed-8691038
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86910382021-12-23 Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study Borjali, Amirhossein Nourani, Amir Moeinnia, Hadi Mohseni, Mahdi Korani, Hossein Ghias, Narges Chizari, Mahmoud BMC Musculoskelet Disord Research BACKGROUND: Bone and Site Hold Tendon Inside (BASHTI) technique is an organic implant-less technique for anterior cruciate ligament (ACL) reconstruction with some clinical advantages, such as speeding up the healing process, over implantable techniques. The study aims to compare the mechanical properties of BASHTI technique with the conventional interference screw technique. METHODS: To investigate the mechanical properties, 20 in-vitro experimental tests were conducted. Synthetic dummy bone, along with fresh digital bovine tendons, as a graft, were used for experiments. Three loading steps were applied to all specimens, including a preconditioning, a main cyclic, and a pull-out loading. RESULTS: The mechanical characters of an interference screw technique using an 8 mm tendon diameter, including fixation strength, average cyclic stiffness (ACS), and average pull-out stiffness (APS) were found to be 439 ± 132 N, 10.3 ± 5.3 kN/mm, and 109 ± 40 N/mm, respectively. In the case of an interference screw using a 9 mm tendon, the fixation strength, ACS, and APS were obtained 549 ± 87 N, 10.3 ± 4.7 kN/mm, and 91 ± 13 N/mm, respectively. In parallel, the fixation strength, APS, and ACS of BASHTI technique using an 8 mm tendon were 360 ± 123 N, 3.3 ± 0.6 kN/mm, and 79 ± 27 N/mm, respectively, while, for 9 mm tendon 278 ± 103 N, 2.4 ± 1.2 kN/mm, and 111 ± 40 N/mm, were reported for fixation strength, APS, and ACS respectively when BASHTI technique was used. CONCLUSION: About 50% of interference screw samples showed superior mechanical properties compared to BASHTI technique, but in another half of the samples, the differences were not significant (N.S.). However, due to organic advantages of BASHTI technique and lower cost, it could be used as a substitute for interference screw technique, especially where fast recovery is expected. BioMed Central 2021-12-20 /pmc/articles/PMC8691038/ /pubmed/34930185 http://dx.doi.org/10.1186/s12891-021-04788-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Borjali, Amirhossein
Nourani, Amir
Moeinnia, Hadi
Mohseni, Mahdi
Korani, Hossein
Ghias, Narges
Chizari, Mahmoud
Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title_full Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title_fullStr Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title_full_unstemmed Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title_short Comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
title_sort comparison of mechanical properties in interference screw fixation technique and organic anterior cruciate ligament reconstruction method: a biomechanical study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691038/
https://www.ncbi.nlm.nih.gov/pubmed/34930185
http://dx.doi.org/10.1186/s12891-021-04788-3
work_keys_str_mv AT borjaliamirhossein comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT nouraniamir comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT moeinniahadi comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT mohsenimahdi comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT koranihossein comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT ghiasnarges comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy
AT chizarimahmoud comparisonofmechanicalpropertiesininterferencescrewfixationtechniqueandorganicanteriorcruciateligamentreconstructionmethodabiomechanicalstudy