Cargando…

Rescue transventricular off-pump mitral valve repair with artificial neochords for acute mitral regurgitation due to postinfarction papillary muscle rupture

BACKGROUND: We report 3 cases of rescue transventricular off-pump mitral valve (MV) repair in high-risk patients with acute mitral regurgitation (MR) due to post–myocardial infarction (MI) papillary muscle rupture (PMR). METHODS: The 3 patients presented with acute inferior ST elevation myocardial i...

Descripción completa

Detalles Bibliográficos
Autores principales: Budra, Mindaugas, Janušauskas, Vilius, Zorinas, Aleksejus, Zakarkaitė, Diana, Aidietis, Audrius, Samalavičius, Robertas, Ručinskas, Kęstutis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691823/
https://www.ncbi.nlm.nih.gov/pubmed/34977729
http://dx.doi.org/10.1016/j.xjtc.2021.09.047
Descripción
Sumario:BACKGROUND: We report 3 cases of rescue transventricular off-pump mitral valve (MV) repair in high-risk patients with acute mitral regurgitation (MR) due to post–myocardial infarction (MI) papillary muscle rupture (PMR). METHODS: The 3 patients presented with acute inferior ST elevation myocardial infarction, cardiogenic shock, and pulmonary edema. Their preoperative peak troponin I levels were 1909 ng/L, 16,963 ng/L, and 8299 ng/L. All 3 patients underwent successful percutaneous intervention to the culprit coronary artery, and antiplatelet therapy was initiated. All patients required inotropic support and had an intra-aortic balloon pump inserted preoperatively. Transesophageal echocardiography (TEE) demonstrated severe eccentric MR due to the leaflet prolapse secondary to PMR. The patients’ estimated EuroSCORE II scores were 16.03%, 16.68%, and 7.81%, and their Society of Thoracic Surgeons scores were 14.77%, 18.24%, and 9.8%, respectively. All 3 patients underwent urgent transventricular off-pump MV repair using artificial chords, with 2 or 3 three neochords implanted. The duration of operation was <2 hours, and intraoperative and postoperative drainage was minimal in all cases. MV function was assessed by qualitative and semiquantitative TEE. RESULTS: Intraoperative MR reduction to a mild level was achieved in all 3 patients. All patients had moderate MR at discharge, likely due to left ventricular remodeling. Severe MR recurred in all patients, at 5, 4, and 2 months of follow-up, respectively. All 3 patients underwent an elective MV reoperation via conventional approach. CONCLUSIONS: Off-pump transventricular MV repair may offer a safe and feasible alternative to stabilize high-risk patients with acute MR due to post-MI PMR. Although early MR recurrence is concerning, urgent transventricular MV repair may serve as a bridge to conventional surgery in such unstable patients.