Cargando…

Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera

The aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium–zinc–telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamane, Tomohiko, Takahashi, Masafumi, Matsusaka, Yohji, Fukushima, Kenji, Seto, Akira, Kuji, Ichiei, Matsunari, Ichiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8692318/
https://www.ncbi.nlm.nih.gov/pubmed/34934145
http://dx.doi.org/10.1038/s41598-021-03853-0
_version_ 1784618935136550912
author Yamane, Tomohiko
Takahashi, Masafumi
Matsusaka, Yohji
Fukushima, Kenji
Seto, Akira
Kuji, Ichiei
Matsunari, Ichiro
author_facet Yamane, Tomohiko
Takahashi, Masafumi
Matsusaka, Yohji
Fukushima, Kenji
Seto, Akira
Kuji, Ichiei
Matsunari, Ichiro
author_sort Yamane, Tomohiko
collection PubMed
description The aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium–zinc–telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from prostate cancer, who underwent SPECT/CT performed on whole-body CZT gamma cameras. STSs were obtained using 75, 50, 25, 10, and 5% of the list-mode data for SS, respectively. Regions of interest (ROIs) were set on the increased uptake areas diagnosed as metastases. Intraclass correlation coefficients (ICCs) of standardized uptake values (SUVs) for the ROIs were calculated between the SS and each STS, and ICC ≥ 0.8 was set as a perfect correlation. Moreover, the repeatability coefficient (RC) was calculated, and RC ≤ 20% was defined as acceptable. A total of 152 metastatic lesions were included in the analysis. The ICCs between the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 0.999, 0.997, 0.994, 0.983, and 0.955, respectively. The RCs of the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 7.9, 12.4, 19.8, 30.8, and 41.3%, respectively. When evaluating the quality of CZT bone SPECT/CT acquired by a standard protocol, 25%-STS may provide adequate quantitative values.
format Online
Article
Text
id pubmed-8692318
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-86923182021-12-22 Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera Yamane, Tomohiko Takahashi, Masafumi Matsusaka, Yohji Fukushima, Kenji Seto, Akira Kuji, Ichiei Matsunari, Ichiro Sci Rep Article The aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium–zinc–telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from prostate cancer, who underwent SPECT/CT performed on whole-body CZT gamma cameras. STSs were obtained using 75, 50, 25, 10, and 5% of the list-mode data for SS, respectively. Regions of interest (ROIs) were set on the increased uptake areas diagnosed as metastases. Intraclass correlation coefficients (ICCs) of standardized uptake values (SUVs) for the ROIs were calculated between the SS and each STS, and ICC ≥ 0.8 was set as a perfect correlation. Moreover, the repeatability coefficient (RC) was calculated, and RC ≤ 20% was defined as acceptable. A total of 152 metastatic lesions were included in the analysis. The ICCs between the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 0.999, 0.997, 0.994, 0.983, and 0.955, respectively. The RCs of the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 7.9, 12.4, 19.8, 30.8, and 41.3%, respectively. When evaluating the quality of CZT bone SPECT/CT acquired by a standard protocol, 25%-STS may provide adequate quantitative values. Nature Publishing Group UK 2021-12-21 /pmc/articles/PMC8692318/ /pubmed/34934145 http://dx.doi.org/10.1038/s41598-021-03853-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Yamane, Tomohiko
Takahashi, Masafumi
Matsusaka, Yohji
Fukushima, Kenji
Seto, Akira
Kuji, Ichiei
Matsunari, Ichiro
Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title_full Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title_fullStr Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title_full_unstemmed Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title_short Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera
title_sort satisfied quantitative value can be acquired by short-time bone spect/ct using a whole-body cadmium–zinc–telluride gamma camera
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8692318/
https://www.ncbi.nlm.nih.gov/pubmed/34934145
http://dx.doi.org/10.1038/s41598-021-03853-0
work_keys_str_mv AT yamanetomohiko satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT takahashimasafumi satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT matsusakayohji satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT fukushimakenji satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT setoakira satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT kujiichiei satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera
AT matsunariichiro satisfiedquantitativevaluecanbeacquiredbyshorttimebonespectctusingawholebodycadmiumzinctelluridegammacamera