Cargando…
Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
Electrical stimulation for application in tissue engineering and regenerative medicine has received increasing attention in recent years. A variety of stimulation methods, waveforms and amplitudes have been studied. However, a clear choice of optimal stimulation parameters is still not available and...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8693021/ https://www.ncbi.nlm.nih.gov/pubmed/34957068 http://dx.doi.org/10.3389/fbioe.2021.765516 |
_version_ | 1784619057230643200 |
---|---|
author | Zimmermann, Julius Budde, Kai Arbeiter, Nils Molina, Francia Storch, Alexander Uhrmacher, Adelinde M. van Rienen, Ursula |
author_facet | Zimmermann, Julius Budde, Kai Arbeiter, Nils Molina, Francia Storch, Alexander Uhrmacher, Adelinde M. van Rienen, Ursula |
author_sort | Zimmermann, Julius |
collection | PubMed |
description | Electrical stimulation for application in tissue engineering and regenerative medicine has received increasing attention in recent years. A variety of stimulation methods, waveforms and amplitudes have been studied. However, a clear choice of optimal stimulation parameters is still not available and is complicated by ambiguous reporting standards. In order to understand underlying cellular mechanisms affected by the electrical stimulation, the knowledge of the actual prevailing field strength or current density is required. Here, we present a comprehensive digital representation, a digital twin, of a basic electrical stimulation device for the electrical stimulation of cells in vitro. The effect of electrochemical processes at the electrode surface was experimentally characterised and integrated into a numerical model of the electrical stimulation. Uncertainty quantification techniques were used to identify the influence of model uncertainties on relevant observables. Different stimulation protocols were compared and it was assessed if the information contained in the monitored stimulation pulses could be related to the stimulation model. We found that our approach permits to model and simulate the recorded rectangular waveforms such that local electric field strengths become accessible. Moreover, we could predict stimulation voltages and currents reliably. This enabled us to define a controlled stimulation setting and to identify significant temperature changes of the cell culture in the monitored voltage data. Eventually, we give an outlook on how the presented methods can be applied in more complex situations such as the stimulation of hydrogels or tissue in vivo. |
format | Online Article Text |
id | pubmed-8693021 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86930212021-12-23 Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro Zimmermann, Julius Budde, Kai Arbeiter, Nils Molina, Francia Storch, Alexander Uhrmacher, Adelinde M. van Rienen, Ursula Front Bioeng Biotechnol Bioengineering and Biotechnology Electrical stimulation for application in tissue engineering and regenerative medicine has received increasing attention in recent years. A variety of stimulation methods, waveforms and amplitudes have been studied. However, a clear choice of optimal stimulation parameters is still not available and is complicated by ambiguous reporting standards. In order to understand underlying cellular mechanisms affected by the electrical stimulation, the knowledge of the actual prevailing field strength or current density is required. Here, we present a comprehensive digital representation, a digital twin, of a basic electrical stimulation device for the electrical stimulation of cells in vitro. The effect of electrochemical processes at the electrode surface was experimentally characterised and integrated into a numerical model of the electrical stimulation. Uncertainty quantification techniques were used to identify the influence of model uncertainties on relevant observables. Different stimulation protocols were compared and it was assessed if the information contained in the monitored stimulation pulses could be related to the stimulation model. We found that our approach permits to model and simulate the recorded rectangular waveforms such that local electric field strengths become accessible. Moreover, we could predict stimulation voltages and currents reliably. This enabled us to define a controlled stimulation setting and to identify significant temperature changes of the cell culture in the monitored voltage data. Eventually, we give an outlook on how the presented methods can be applied in more complex situations such as the stimulation of hydrogels or tissue in vivo. Frontiers Media S.A. 2021-12-08 /pmc/articles/PMC8693021/ /pubmed/34957068 http://dx.doi.org/10.3389/fbioe.2021.765516 Text en Copyright © 2021 Zimmermann, Budde, Arbeiter, Molina, Storch, Uhrmacher and van Rienen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Zimmermann, Julius Budde, Kai Arbeiter, Nils Molina, Francia Storch, Alexander Uhrmacher, Adelinde M. van Rienen, Ursula Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro |
title | Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
|
title_full | Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
|
title_fullStr | Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
|
title_full_unstemmed | Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
|
title_short | Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
|
title_sort | using a digital twin of an electrical stimulation device to monitor and control the electrical stimulation of cells in vitro |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8693021/ https://www.ncbi.nlm.nih.gov/pubmed/34957068 http://dx.doi.org/10.3389/fbioe.2021.765516 |
work_keys_str_mv | AT zimmermannjulius usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT buddekai usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT arbeiternils usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT molinafrancia usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT storchalexander usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT uhrmacheradelindem usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro AT vanrienenursula usingadigitaltwinofanelectricalstimulationdevicetomonitorandcontroltheelectricalstimulationofcellsinvitro |