Cargando…

The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment

OBJECTIVES: The purpose of this study was to evaluate rater agreement and the accuracy of a semi-automated software and its fully automated tool for osteoporosis risk assessment in intraoral radiographs. METHODS: A total of 567 intraoral radiographs was selected retrospectively from women aged 75–80...

Descripción completa

Detalles Bibliográficos
Autores principales: Gullberg, Joanna, Al-Okshi, Ayman, Homar Asan, Dalia, Zainea, Anita, Sundh, Daniel, Lorentzon, Mattias, Lindh, Christina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8693323/
https://www.ncbi.nlm.nih.gov/pubmed/34324394
http://dx.doi.org/10.1259/dmfr.20210175
_version_ 1784619121672978432
author Gullberg, Joanna
Al-Okshi, Ayman
Homar Asan, Dalia
Zainea, Anita
Sundh, Daniel
Lorentzon, Mattias
Lindh, Christina
author_facet Gullberg, Joanna
Al-Okshi, Ayman
Homar Asan, Dalia
Zainea, Anita
Sundh, Daniel
Lorentzon, Mattias
Lindh, Christina
author_sort Gullberg, Joanna
collection PubMed
description OBJECTIVES: The purpose of this study was to evaluate rater agreement and the accuracy of a semi-automated software and its fully automated tool for osteoporosis risk assessment in intraoral radiographs. METHODS: A total of 567 intraoral radiographs was selected retrospectively from women aged 75–80 years participating in a large population-based study (SUPERB) based in Gothenburg, Sweden. Five raters assessed participants’ risk of osteoporosis in the intraoral radiographs using a semi-automated software. Assessments were repeated after 4 weeks on 121 radiographs (20%) randomly selected from the original 567. Radiographs were also assessed by the softwares’ fully automated tool for analysis. RESULTS: Overall interrater agreement for the five raters was 0.37 (95% CI 0.32–0.41), and for the five raters with the fully automated tool included as ‘sixth rater’ the overall Kappa was 0.34 (0.30–0.38). Intrarater agreement varied from moderate to substantial according to the Landis and Koch interpretation scale. Diagnostic accuracy was calculated in relation to reference standard for osteoporosis diagnosis which is T-score values for spine, total hip and femoral neck and presented in form of sensitivities, specificities, predictive values, likelihood ratios and odds ratios. All raters' mean sensitivity, including the fully automated tool, was 40,4% (range 14,3%–57,6%). Corresponding values for specificity was 69,5% (range 59,7%–90,4%). The diagnostic odds ratios ranged between 1 and 2.7. CONCLUSION: The low diagnostic odds ratio and agreement between raters in osteoporosis risk assessment using the software for analysis of the trabecular pattern in intraoral radiographs shows that more work needs to be done to optimise the automation of trabecular pattern analysis in intraoral radiographs.
format Online
Article
Text
id pubmed-8693323
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The British Institute of Radiology.
record_format MEDLINE/PubMed
spelling pubmed-86933232023-01-01 The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment Gullberg, Joanna Al-Okshi, Ayman Homar Asan, Dalia Zainea, Anita Sundh, Daniel Lorentzon, Mattias Lindh, Christina Dentomaxillofac Radiol Research Article OBJECTIVES: The purpose of this study was to evaluate rater agreement and the accuracy of a semi-automated software and its fully automated tool for osteoporosis risk assessment in intraoral radiographs. METHODS: A total of 567 intraoral radiographs was selected retrospectively from women aged 75–80 years participating in a large population-based study (SUPERB) based in Gothenburg, Sweden. Five raters assessed participants’ risk of osteoporosis in the intraoral radiographs using a semi-automated software. Assessments were repeated after 4 weeks on 121 radiographs (20%) randomly selected from the original 567. Radiographs were also assessed by the softwares’ fully automated tool for analysis. RESULTS: Overall interrater agreement for the five raters was 0.37 (95% CI 0.32–0.41), and for the five raters with the fully automated tool included as ‘sixth rater’ the overall Kappa was 0.34 (0.30–0.38). Intrarater agreement varied from moderate to substantial according to the Landis and Koch interpretation scale. Diagnostic accuracy was calculated in relation to reference standard for osteoporosis diagnosis which is T-score values for spine, total hip and femoral neck and presented in form of sensitivities, specificities, predictive values, likelihood ratios and odds ratios. All raters' mean sensitivity, including the fully automated tool, was 40,4% (range 14,3%–57,6%). Corresponding values for specificity was 69,5% (range 59,7%–90,4%). The diagnostic odds ratios ranged between 1 and 2.7. CONCLUSION: The low diagnostic odds ratio and agreement between raters in osteoporosis risk assessment using the software for analysis of the trabecular pattern in intraoral radiographs shows that more work needs to be done to optimise the automation of trabecular pattern analysis in intraoral radiographs. The British Institute of Radiology. 2022-01-01 2022-01-01 /pmc/articles/PMC8693323/ /pubmed/34324394 http://dx.doi.org/10.1259/dmfr.20210175 Text en © 2022 The Authors. Published by the British Institute of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial reuse, provided the original author and source are credited.
spellingShingle Research Article
Gullberg, Joanna
Al-Okshi, Ayman
Homar Asan, Dalia
Zainea, Anita
Sundh, Daniel
Lorentzon, Mattias
Lindh, Christina
The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title_full The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title_fullStr The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title_full_unstemmed The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title_short The challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
title_sort challenge of applying digital image processing software on intraoral radiographs for osteoporosis risk assessment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8693323/
https://www.ncbi.nlm.nih.gov/pubmed/34324394
http://dx.doi.org/10.1259/dmfr.20210175
work_keys_str_mv AT gullbergjoanna thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT alokshiayman thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT homarasandalia thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT zaineaanita thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT sundhdaniel thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT lorentzonmattias thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT lindhchristina thechallengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT gullbergjoanna challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT alokshiayman challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT homarasandalia challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT zaineaanita challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT sundhdaniel challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT lorentzonmattias challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment
AT lindhchristina challengeofapplyingdigitalimageprocessingsoftwareonintraoralradiographsforosteoporosisriskassessment