Cargando…

On-line separation/analysis of Rhodamine B dye based on a solid-phase extraction high performance liquid chromatography self-designed device

A special self-designed device based on poly-1-vinyl-3-pentylimidazole hexafluorophosphate (PILs-C(5)) solid-phase extraction and high performance liquid chromatography (HPLC) is proposed as a novel method for the on-line separation and analysis of Rhodamine B (RhB) dye. Single factor experiment des...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Jun, Liu, Wei, Zhu, Rui, Zhu, Xiashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695180/
https://www.ncbi.nlm.nih.gov/pubmed/35423288
http://dx.doi.org/10.1039/d0ra10771a
Descripción
Sumario:A special self-designed device based on poly-1-vinyl-3-pentylimidazole hexafluorophosphate (PILs-C(5)) solid-phase extraction and high performance liquid chromatography (HPLC) is proposed as a novel method for the on-line separation and analysis of Rhodamine B (RhB) dye. Single factor experiment design and orthogonal experiment design were used to optimize the experimental parameters, such as pH, the amount of PILs-C(5), sample volume, flow rate, eluent type, eluent concentration, eluent volume, and the flow rate of eluent. Under the optimized conditions, the linear range was 0.02–2.4 μg mL(−1), with the correlation coefficients (R(2)) of 0.997. The limit of detection (LOD) and limit of quantification (LOQ) were 0.004 μg mL(−1) and 0.02 μg mL(−1), respectively. The extraction capacity was 6.22 mg g(−1), and enrichment ratio was 15. The extraction mechanism and the post-treatment method of PILs-C(5) were also studied. This method was applied to analyze RhB in a wide variety of real samples with satisfactory results.