Cargando…

Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis

PURPOSE: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO(2)) implants. MATERIALS AND METHODS: Six online databases we...

Descripción completa

Detalles Bibliográficos
Autores principales: Chagas, Mariana Murai, Kobayashi-Velasco, Solange, Gimenez, Thais, Cavalcanti, Marcelo Gusmão Paraiso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695475/
https://www.ncbi.nlm.nih.gov/pubmed/34987996
http://dx.doi.org/10.5624/isd.20210120
_version_ 1784619586605285376
author Chagas, Mariana Murai
Kobayashi-Velasco, Solange
Gimenez, Thais
Cavalcanti, Marcelo Gusmão Paraiso
author_facet Chagas, Mariana Murai
Kobayashi-Velasco, Solange
Gimenez, Thais
Cavalcanti, Marcelo Gusmão Paraiso
author_sort Chagas, Mariana Murai
collection PubMed
description PURPOSE: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO(2)) implants. MATERIALS AND METHODS: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. RESULTS: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO(2) and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO(2) group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects (0.73) and fenestration defects (0.87) showed a statistically significant difference. CONCLUSION: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO(2) implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.
format Online
Article
Text
id pubmed-8695475
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-86954752022-01-04 Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis Chagas, Mariana Murai Kobayashi-Velasco, Solange Gimenez, Thais Cavalcanti, Marcelo Gusmão Paraiso Imaging Sci Dent Review Article PURPOSE: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO(2)) implants. MATERIALS AND METHODS: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. RESULTS: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO(2) and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO(2) group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects (0.73) and fenestration defects (0.87) showed a statistically significant difference. CONCLUSION: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO(2) implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants. Korean Academy of Oral and Maxillofacial Radiology 2021-12 2021-11-18 /pmc/articles/PMC8695475/ /pubmed/34987996 http://dx.doi.org/10.5624/isd.20210120 Text en Copyright © 2021 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Chagas, Mariana Murai
Kobayashi-Velasco, Solange
Gimenez, Thais
Cavalcanti, Marcelo Gusmão Paraiso
Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title_full Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title_fullStr Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title_short Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis
title_sort diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: a systematic review and meta-analysis
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695475/
https://www.ncbi.nlm.nih.gov/pubmed/34987996
http://dx.doi.org/10.5624/isd.20210120
work_keys_str_mv AT chagasmarianamurai diagnosticaccuracyofimagingexaminationsforperiimplantbonedefectsaroundtitaniumandzirconiumdioxideimplantsasystematicreviewandmetaanalysis
AT kobayashivelascosolange diagnosticaccuracyofimagingexaminationsforperiimplantbonedefectsaroundtitaniumandzirconiumdioxideimplantsasystematicreviewandmetaanalysis
AT gimenezthais diagnosticaccuracyofimagingexaminationsforperiimplantbonedefectsaroundtitaniumandzirconiumdioxideimplantsasystematicreviewandmetaanalysis
AT cavalcantimarcelogusmaoparaiso diagnosticaccuracyofimagingexaminationsforperiimplantbonedefectsaroundtitaniumandzirconiumdioxideimplantsasystematicreviewandmetaanalysis