Cargando…

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

PURPOSE: This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. MATERIALS AND METHODS: CBCT scans and plaster models from 30 patients wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Yousefi, Faezeh, Shokri, Abbas, Zahedi, Foozie, Farhadian, Maryam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695477/
https://www.ncbi.nlm.nih.gov/pubmed/34988004
http://dx.doi.org/10.5624/isd.20210142
_version_ 1784619587101261824
author Yousefi, Faezeh
Shokri, Abbas
Zahedi, Foozie
Farhadian, Maryam
author_facet Yousefi, Faezeh
Shokri, Abbas
Zahedi, Foozie
Farhadian, Maryam
author_sort Yousefi, Faezeh
collection PubMed
description PURPOSE: This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. MATERIALS AND METHODS: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches’ length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. RESULTS: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements (>0.830) and between observers (>0.801). CONCLUSION: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.
format Online
Article
Text
id pubmed-8695477
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-86954772022-01-04 Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts Yousefi, Faezeh Shokri, Abbas Zahedi, Foozie Farhadian, Maryam Imaging Sci Dent Original Article PURPOSE: This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. MATERIALS AND METHODS: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches’ length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. RESULTS: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements (>0.830) and between observers (>0.801). CONCLUSION: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses. Korean Academy of Oral and Maxillofacial Radiology 2021-12 2021-10-15 /pmc/articles/PMC8695477/ /pubmed/34988004 http://dx.doi.org/10.5624/isd.20210142 Text en Copyright © 2021 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yousefi, Faezeh
Shokri, Abbas
Zahedi, Foozie
Farhadian, Maryam
Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title_full Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title_fullStr Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title_full_unstemmed Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title_short Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
title_sort assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695477/
https://www.ncbi.nlm.nih.gov/pubmed/34988004
http://dx.doi.org/10.5624/isd.20210142
work_keys_str_mv AT yousefifaezeh assessmentoftheaccuracyoflaserscannedmodelsand3dimensionalrenderedconebeamcomputedtomographicimagescomparedtodigitalcalipermeasurementsonplastercasts
AT shokriabbas assessmentoftheaccuracyoflaserscannedmodelsand3dimensionalrenderedconebeamcomputedtomographicimagescomparedtodigitalcalipermeasurementsonplastercasts
AT zahedifoozie assessmentoftheaccuracyoflaserscannedmodelsand3dimensionalrenderedconebeamcomputedtomographicimagescomparedtodigitalcalipermeasurementsonplastercasts
AT farhadianmaryam assessmentoftheaccuracyoflaserscannedmodelsand3dimensionalrenderedconebeamcomputedtomographicimagescomparedtodigitalcalipermeasurementsonplastercasts