Cargando…
A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection
This study describes the development, verification and practical application of an aptasensor for the fluorometric detection of kanamycin. Using the nucleic acid aptamer with FAM fluorescent group as the conjugate, using gold nanoparticles as the fluorescence dynamic quenching source, a fluorescence...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695508/ https://www.ncbi.nlm.nih.gov/pubmed/35423483 http://dx.doi.org/10.1039/d0ra10602j |
_version_ | 1784619594479042560 |
---|---|
author | Sun, Yimeng Qi, Tong Jin, Yan Liang, Lijuan Zhao, Jianlong |
author_facet | Sun, Yimeng Qi, Tong Jin, Yan Liang, Lijuan Zhao, Jianlong |
author_sort | Sun, Yimeng |
collection | PubMed |
description | This study describes the development, verification and practical application of an aptasensor for the fluorometric detection of kanamycin. Using the nucleic acid aptamer with FAM fluorescent group as the conjugate, using gold nanoparticles as the fluorescence dynamic quenching source, a fluorescence sensor was fabricated through the signal-on method for the micro-detection of kanamycin. The nucleic acid chimera is connected to the fluorophore, and the gold nanoparticles are used as the fluorescence dynamic quenching source under actual conditions. The detection limit of kanamycin is 0.1 pM, and the detection range is 0.1 pM to 0.1 μM. This biosensor works satisfactorily in complex samples with no impurities, which gives this method an obvious advantage over other analytical methods. In addition, the mechanism of action between gold nanoparticles/FAM–aptamer/kanamycin is discussed and studied in depth here. It provides a more thorough analysis and more application possibilities for fluorescence-aptamer biosensing. |
format | Online Article Text |
id | pubmed-8695508 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-86955082022-04-13 A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection Sun, Yimeng Qi, Tong Jin, Yan Liang, Lijuan Zhao, Jianlong RSC Adv Chemistry This study describes the development, verification and practical application of an aptasensor for the fluorometric detection of kanamycin. Using the nucleic acid aptamer with FAM fluorescent group as the conjugate, using gold nanoparticles as the fluorescence dynamic quenching source, a fluorescence sensor was fabricated through the signal-on method for the micro-detection of kanamycin. The nucleic acid chimera is connected to the fluorophore, and the gold nanoparticles are used as the fluorescence dynamic quenching source under actual conditions. The detection limit of kanamycin is 0.1 pM, and the detection range is 0.1 pM to 0.1 μM. This biosensor works satisfactorily in complex samples with no impurities, which gives this method an obvious advantage over other analytical methods. In addition, the mechanism of action between gold nanoparticles/FAM–aptamer/kanamycin is discussed and studied in depth here. It provides a more thorough analysis and more application possibilities for fluorescence-aptamer biosensing. The Royal Society of Chemistry 2021-03-08 /pmc/articles/PMC8695508/ /pubmed/35423483 http://dx.doi.org/10.1039/d0ra10602j Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Sun, Yimeng Qi, Tong Jin, Yan Liang, Lijuan Zhao, Jianlong A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title | A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title_full | A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title_fullStr | A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title_full_unstemmed | A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title_short | A signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
title_sort | signal-on fluorescent aptasensor based on gold nanoparticles for kanamycin detection |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695508/ https://www.ncbi.nlm.nih.gov/pubmed/35423483 http://dx.doi.org/10.1039/d0ra10602j |
work_keys_str_mv | AT sunyimeng asignalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT qitong asignalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT jinyan asignalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT lianglijuan asignalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT zhaojianlong asignalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT sunyimeng signalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT qitong signalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT jinyan signalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT lianglijuan signalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection AT zhaojianlong signalonfluorescentaptasensorbasedongoldnanoparticlesforkanamycindetection |