Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial

Introduction: Cardiovascular accidents are the world's leading cause of death. A good quality cardiopulmonary resuscitation (CPR) can reduce cardiac arrest-associated mortality. This study aims to test the coaching system of a wearable glove, providing instructions during out-of-hospital CPR. M...

Descripción completa

Detalles Bibliográficos
Autores principales: Musiari, Michele, Saporito, Andrea, Ceruti, Samuele, Biggiogero, Maira, Iattoni, Martina, Glotta, Andrea, Cantini, Laura, Capdevila, Xavier, Cassina, Tiziano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695546/
https://www.ncbi.nlm.nih.gov/pubmed/34957226
http://dx.doi.org/10.3389/fcvm.2021.685988
_version_ 1784619603347898368
author Musiari, Michele
Saporito, Andrea
Ceruti, Samuele
Biggiogero, Maira
Iattoni, Martina
Glotta, Andrea
Cantini, Laura
Capdevila, Xavier
Cassina, Tiziano
author_facet Musiari, Michele
Saporito, Andrea
Ceruti, Samuele
Biggiogero, Maira
Iattoni, Martina
Glotta, Andrea
Cantini, Laura
Capdevila, Xavier
Cassina, Tiziano
author_sort Musiari, Michele
collection PubMed
description Introduction: Cardiovascular accidents are the world's leading cause of death. A good quality cardiopulmonary resuscitation (CPR) can reduce cardiac arrest-associated mortality. This study aims to test the coaching system of a wearable glove, providing instructions during out-of-hospital CPR. Materials and Methods: We performed a single-blind, controlled trial to test non-healthcare professionals during a simulated CPR performed on an electronic mannequin. The no-glove group was the control. The primary outcome was to compare the accuracy of depth and frequency of two simulated CPR sessions. Secondary outcomes were to compare the decay of CPR performance and the percentage of the duration of accurate CPR. Results: About 130 volunteers were allocated to 1:1 ratio in both groups; mean age was 36 ± 15 years (min–max 21–64) and 62 (48%) were men; 600 chest compressions were performed, and 571 chest compressions were analyzed. The mean frequency in the glove group was 117.67 vs. 103.02 rpm in the control group (p < 0.001). The appropriate rate cycle was 92.4% in the glove group vs. 71% in the control group, with a difference of 21.4% (p < 0.001). Mean compression depth in the glove group was 52.11 vs. 55.17 mm in the control group (p < 0.001). A mean reduction of compression depth over time of 5.3 mm/min was observed in the control group vs. 0.83 mm/min of reduction in the glove group. Conclusion: Visual and acoustic feedbacks provided through the utilization of the glove's coaching system were useful for non-healthcare professionals' CPR performance.
format Online
Article
Text
id pubmed-8695546
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86955462021-12-24 Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial Musiari, Michele Saporito, Andrea Ceruti, Samuele Biggiogero, Maira Iattoni, Martina Glotta, Andrea Cantini, Laura Capdevila, Xavier Cassina, Tiziano Front Cardiovasc Med Cardiovascular Medicine Introduction: Cardiovascular accidents are the world's leading cause of death. A good quality cardiopulmonary resuscitation (CPR) can reduce cardiac arrest-associated mortality. This study aims to test the coaching system of a wearable glove, providing instructions during out-of-hospital CPR. Materials and Methods: We performed a single-blind, controlled trial to test non-healthcare professionals during a simulated CPR performed on an electronic mannequin. The no-glove group was the control. The primary outcome was to compare the accuracy of depth and frequency of two simulated CPR sessions. Secondary outcomes were to compare the decay of CPR performance and the percentage of the duration of accurate CPR. Results: About 130 volunteers were allocated to 1:1 ratio in both groups; mean age was 36 ± 15 years (min–max 21–64) and 62 (48%) were men; 600 chest compressions were performed, and 571 chest compressions were analyzed. The mean frequency in the glove group was 117.67 vs. 103.02 rpm in the control group (p < 0.001). The appropriate rate cycle was 92.4% in the glove group vs. 71% in the control group, with a difference of 21.4% (p < 0.001). Mean compression depth in the glove group was 52.11 vs. 55.17 mm in the control group (p < 0.001). A mean reduction of compression depth over time of 5.3 mm/min was observed in the control group vs. 0.83 mm/min of reduction in the glove group. Conclusion: Visual and acoustic feedbacks provided through the utilization of the glove's coaching system were useful for non-healthcare professionals' CPR performance. Frontiers Media S.A. 2021-12-09 /pmc/articles/PMC8695546/ /pubmed/34957226 http://dx.doi.org/10.3389/fcvm.2021.685988 Text en Copyright © 2021 Musiari, Saporito, Ceruti, Biggiogero, Iattoni, Glotta, Cantini, Capdevila and Cassina. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Musiari, Michele
Saporito, Andrea
Ceruti, Samuele
Biggiogero, Maira
Iattoni, Martina
Glotta, Andrea
Cantini, Laura
Capdevila, Xavier
Cassina, Tiziano
Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title_full Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title_fullStr Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title_full_unstemmed Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title_short Can a Glove-Coach Technology Significantly Increase the Efficacy of Cardiopulmonary Resuscitation on Non-healthcare Professionals? A Controlled Trial
title_sort can a glove-coach technology significantly increase the efficacy of cardiopulmonary resuscitation on non-healthcare professionals? a controlled trial
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8695546/
https://www.ncbi.nlm.nih.gov/pubmed/34957226
http://dx.doi.org/10.3389/fcvm.2021.685988
work_keys_str_mv AT musiarimichele canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT saporitoandrea canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT cerutisamuele canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT biggiogeromaira canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT iattonimartina canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT glottaandrea canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT cantinilaura canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT capdevilaxavier canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial
AT cassinatiziano canaglovecoachtechnologysignificantlyincreasetheefficacyofcardiopulmonaryresuscitationonnonhealthcareprofessionalsacontrolledtrial