Cargando…

Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors

PURPOSE: This study aimed to determine the diagnostic performance of the controlled attenuation parameter (CAP) measured using transient elastography (TE) for assessing macrovesicular steatosis (MaS) in potential living liver donors using same-day biopsy as a reference standard. METHODS: This retros...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sunyoung, Kim, Kyoung Won, Kim, So Yeon, Seo, Nieun, Song, Gi-Won, Lee, Sung-Gyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696135/
https://www.ncbi.nlm.nih.gov/pubmed/34399042
http://dx.doi.org/10.14366/usg.21071
_version_ 1784619739194064896
author Lee, Sunyoung
Kim, Kyoung Won
Kim, So Yeon
Seo, Nieun
Song, Gi-Won
Lee, Sung-Gyu
author_facet Lee, Sunyoung
Kim, Kyoung Won
Kim, So Yeon
Seo, Nieun
Song, Gi-Won
Lee, Sung-Gyu
author_sort Lee, Sunyoung
collection PubMed
description PURPOSE: This study aimed to determine the diagnostic performance of the controlled attenuation parameter (CAP) measured using transient elastography (TE) for assessing macrovesicular steatosis (MaS) in potential living liver donors using same-day biopsy as a reference standard. METHODS: This retrospective study included 204 living liver donor candidates who underwent TE and liver biopsy on the same day between July 2013 and June 2014. The histologic degree of MaS was determined. The area under the receiver operating characteristic curve (AUROC) was used to evaluate the performance of CAP for diagnosing MaS of >10%, and the optimal cutoff value was identified using the maximal Youden index. RESULTS: Based on liver biopsy, 185 subjects had MaS of ≤10% and 19 had MaS of >10%. The CAP value was significantly correlated with the percentage of MaS on liver biopsy (r=0.635, P<0.001), and the median CAP value was significantly higher in subjects with MaS of >10% than in those with MaS of ≤10% (300 dB/m vs. 209 dB/m, P<0.001). The AUROC for diagnosing MaS of >10% by CAP was 0.938 (95% confidence interval, 0.896 to 0.967), and a CAP of >259 dB/m yielded a sensitivity of 84.2% and a specificity of 92.4%. CONCLUSION: The CAP measured using TE was significantly correlated with MaS and accurately detected substantial MaS in potential living liver donors. The CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates.
format Online
Article
Text
id pubmed-8696135
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-86961352022-01-06 Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors Lee, Sunyoung Kim, Kyoung Won Kim, So Yeon Seo, Nieun Song, Gi-Won Lee, Sung-Gyu Ultrasonography Original Article PURPOSE: This study aimed to determine the diagnostic performance of the controlled attenuation parameter (CAP) measured using transient elastography (TE) for assessing macrovesicular steatosis (MaS) in potential living liver donors using same-day biopsy as a reference standard. METHODS: This retrospective study included 204 living liver donor candidates who underwent TE and liver biopsy on the same day between July 2013 and June 2014. The histologic degree of MaS was determined. The area under the receiver operating characteristic curve (AUROC) was used to evaluate the performance of CAP for diagnosing MaS of >10%, and the optimal cutoff value was identified using the maximal Youden index. RESULTS: Based on liver biopsy, 185 subjects had MaS of ≤10% and 19 had MaS of >10%. The CAP value was significantly correlated with the percentage of MaS on liver biopsy (r=0.635, P<0.001), and the median CAP value was significantly higher in subjects with MaS of >10% than in those with MaS of ≤10% (300 dB/m vs. 209 dB/m, P<0.001). The AUROC for diagnosing MaS of >10% by CAP was 0.938 (95% confidence interval, 0.896 to 0.967), and a CAP of >259 dB/m yielded a sensitivity of 84.2% and a specificity of 92.4%. CONCLUSION: The CAP measured using TE was significantly correlated with MaS and accurately detected substantial MaS in potential living liver donors. The CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates. Korean Society of Ultrasound in Medicine 2022-01 2021-06-06 /pmc/articles/PMC8696135/ /pubmed/34399042 http://dx.doi.org/10.14366/usg.21071 Text en Copyright © 2022 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Sunyoung
Kim, Kyoung Won
Kim, So Yeon
Seo, Nieun
Song, Gi-Won
Lee, Sung-Gyu
Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title_full Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title_fullStr Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title_full_unstemmed Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title_short Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
title_sort controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696135/
https://www.ncbi.nlm.nih.gov/pubmed/34399042
http://dx.doi.org/10.14366/usg.21071
work_keys_str_mv AT leesunyoung controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors
AT kimkyoungwon controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors
AT kimsoyeon controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors
AT seonieun controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors
AT songgiwon controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors
AT leesunggyu controlledattenuationparametermeasuredusingtransientelastographyforthenoninvasiveassessmentofmacrovesicularsteatosisinpotentiallivingliverdonors