Cargando…
Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia
PURPOSE: The aim of this study was to determine the effectiveness of two different lung ultrasonography (LUS) methods that can be used in the diagnosis of coronavirus disease 2019 (COVID-19) and to investigate their correlations with computed tomography (CT). METHODS: In this prospective, randomized...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696151/ https://www.ncbi.nlm.nih.gov/pubmed/34711019 http://dx.doi.org/10.14366/usg.21095 |
_version_ | 1784619743019270144 |
---|---|
author | Ökmen, Korgün Yildiz, Durdu Kahraman Soyaslan, Emel Ceylan, İlkay Sayan, Halil Erkan Aytünür, Cihan Sedat |
author_facet | Ökmen, Korgün Yildiz, Durdu Kahraman Soyaslan, Emel Ceylan, İlkay Sayan, Halil Erkan Aytünür, Cihan Sedat |
author_sort | Ökmen, Korgün |
collection | PubMed |
description | PURPOSE: The aim of this study was to determine the effectiveness of two different lung ultrasonography (LUS) methods that can be used in the diagnosis of coronavirus disease 2019 (COVID-19) and to investigate their correlations with computed tomography (CT). METHODS: In this prospective, randomized, and single-blind study, 60 patients with COVID-19 were included. The patients were randomized to either the 12-zone LUS group (n=30) or the 14-zone LUS group (n=30). The correlation between LUS and thoracic CT scores was evaluated. As a secondary outcome measure, the characteristic features of the findings of thoracic CT and LUS were examined. RESULTS: The study was completed with a total of 59 patients. Moderate and high correlations were found between the total CT and LUS scores in the 12-zone and 14-zone study groups. There were no statistically significant differences in the lesion types detected in patients using LUS and CT (P>0.05). The left lung lower lobe CT scores were statistically significantly lower in the 14-zone study group than in the 12-zone group (P=0.019). The left lower lobe CT and LUS scores were highly correlated in the 14-zone group (P<0.001, r=0.902). CONCLUSION: The results of our study indicated that the two different LUS examination methods performed in different patients had similar findings in terms of the diagnosis and their correlations with CT results. |
format | Online Article Text |
id | pubmed-8696151 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-86961512022-01-06 Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia Ökmen, Korgün Yildiz, Durdu Kahraman Soyaslan, Emel Ceylan, İlkay Sayan, Halil Erkan Aytünür, Cihan Sedat Ultrasonography Original Article PURPOSE: The aim of this study was to determine the effectiveness of two different lung ultrasonography (LUS) methods that can be used in the diagnosis of coronavirus disease 2019 (COVID-19) and to investigate their correlations with computed tomography (CT). METHODS: In this prospective, randomized, and single-blind study, 60 patients with COVID-19 were included. The patients were randomized to either the 12-zone LUS group (n=30) or the 14-zone LUS group (n=30). The correlation between LUS and thoracic CT scores was evaluated. As a secondary outcome measure, the characteristic features of the findings of thoracic CT and LUS were examined. RESULTS: The study was completed with a total of 59 patients. Moderate and high correlations were found between the total CT and LUS scores in the 12-zone and 14-zone study groups. There were no statistically significant differences in the lesion types detected in patients using LUS and CT (P>0.05). The left lung lower lobe CT scores were statistically significantly lower in the 14-zone study group than in the 12-zone group (P=0.019). The left lower lobe CT and LUS scores were highly correlated in the 14-zone group (P<0.001, r=0.902). CONCLUSION: The results of our study indicated that the two different LUS examination methods performed in different patients had similar findings in terms of the diagnosis and their correlations with CT results. Korean Society of Ultrasound in Medicine 2022-01 2021-07-13 /pmc/articles/PMC8696151/ /pubmed/34711019 http://dx.doi.org/10.14366/usg.21095 Text en Copyright © 2022 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Ökmen, Korgün Yildiz, Durdu Kahraman Soyaslan, Emel Ceylan, İlkay Sayan, Halil Erkan Aytünür, Cihan Sedat Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title | Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title_full | Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title_fullStr | Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title_full_unstemmed | Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title_short | Comparison of two different lung ultrasound imaging protocols in COVID-19 pneumonia |
title_sort | comparison of two different lung ultrasound imaging protocols in covid-19 pneumonia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696151/ https://www.ncbi.nlm.nih.gov/pubmed/34711019 http://dx.doi.org/10.14366/usg.21095 |
work_keys_str_mv | AT okmenkorgun comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia AT yildizdurdukahraman comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia AT soyaslanemel comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia AT ceylanilkay comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia AT sayanhalilerkan comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia AT aytunurcihansedat comparisonoftwodifferentlungultrasoundimagingprotocolsincovid19pneumonia |