Cargando…

Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam

CATEGORY: Trauma INTRODUCTION/PURPOSE: Improved body-armor and mine resistant vehicles have improved battlefield survivability, but now nearly 50% of casualties have a musculoskeletal extremity injury. The purpose of the current study was to evaluate current SAM splint techniques utilized for a dist...

Descripción completa

Detalles Bibliográficos
Autores principales: Martin, Kevin D., Unangst, Alicia, Chisholm, Jaime
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696418/
http://dx.doi.org/10.1177/2473011419S00297
_version_ 1784619807443779584
author Martin, Kevin D.
Unangst, Alicia
Chisholm, Jaime
author_facet Martin, Kevin D.
Unangst, Alicia
Chisholm, Jaime
author_sort Martin, Kevin D.
collection PubMed
description CATEGORY: Trauma INTRODUCTION/PURPOSE: Improved body-armor and mine resistant vehicles have improved battlefield survivability, but now nearly 50% of casualties have a musculoskeletal extremity injury. The purpose of the current study was to evaluate current SAM splint techniques utilized for a distal Tib/Fib fracture verse a new one-step spray on foam immobilization technique. METHODS: A cadaveric model with a distal third combined tibia-fibula fracture was used for testing. The specimens were placed in an austere environment and participants immobilized the injury with standard equipment (SAM splint, 6in Ace wrap). The test group immobilized the injury with a one-step in-situ spray on foam splint. RESULTS: Twenty-one military Joint Special Operations Command (JSOC) medical personnel (11 Medics, 4 PAs, 6 Physicians) participated with an average of 7.7 years as a provider and 25.4 months deployed in a combat theater. Each participant was observed and scored by a single orthopedic foot and ankle surgeon using a Likert scale based on 10 splinting criteria. Standard SAM splinting resulted in an average score of 32.2 (range, 5-50), with significant deficiencies in fracture traction (1/5), fracture motion (2.9/5), protection of neurovascular structures (3/5), and soft tissue manipulation (3/5). The average time to completion was (203 sec), with one splint failure. The spray on foam splinting technique yielded a significantly higher score of 48.5 while completing the task significantly faster at 68 sec with no failures. CONCLUSION: JSOC medical personnel demonstrated overwhelming success in immobilizing a complex extremity fracture with a SAM splint. Testing demonstrated the inherent inability of the SAM splint to provide longitudinal traction while simultaneously allowing excessive fracture motion and potential injury to the soft tissues. In addition, our spray-on foam proof of concept technique eliminated motion and provided traction by allowing in-situ application with adequate rigidity.
format Online
Article
Text
id pubmed-8696418
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-86964182022-01-28 Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam Martin, Kevin D. Unangst, Alicia Chisholm, Jaime Foot Ankle Orthop Article CATEGORY: Trauma INTRODUCTION/PURPOSE: Improved body-armor and mine resistant vehicles have improved battlefield survivability, but now nearly 50% of casualties have a musculoskeletal extremity injury. The purpose of the current study was to evaluate current SAM splint techniques utilized for a distal Tib/Fib fracture verse a new one-step spray on foam immobilization technique. METHODS: A cadaveric model with a distal third combined tibia-fibula fracture was used for testing. The specimens were placed in an austere environment and participants immobilized the injury with standard equipment (SAM splint, 6in Ace wrap). The test group immobilized the injury with a one-step in-situ spray on foam splint. RESULTS: Twenty-one military Joint Special Operations Command (JSOC) medical personnel (11 Medics, 4 PAs, 6 Physicians) participated with an average of 7.7 years as a provider and 25.4 months deployed in a combat theater. Each participant was observed and scored by a single orthopedic foot and ankle surgeon using a Likert scale based on 10 splinting criteria. Standard SAM splinting resulted in an average score of 32.2 (range, 5-50), with significant deficiencies in fracture traction (1/5), fracture motion (2.9/5), protection of neurovascular structures (3/5), and soft tissue manipulation (3/5). The average time to completion was (203 sec), with one splint failure. The spray on foam splinting technique yielded a significantly higher score of 48.5 while completing the task significantly faster at 68 sec with no failures. CONCLUSION: JSOC medical personnel demonstrated overwhelming success in immobilizing a complex extremity fracture with a SAM splint. Testing demonstrated the inherent inability of the SAM splint to provide longitudinal traction while simultaneously allowing excessive fracture motion and potential injury to the soft tissues. In addition, our spray-on foam proof of concept technique eliminated motion and provided traction by allowing in-situ application with adequate rigidity. SAGE Publications 2019-10-28 /pmc/articles/PMC8696418/ http://dx.doi.org/10.1177/2473011419S00297 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Martin, Kevin D.
Unangst, Alicia
Chisholm, Jaime
Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title_full Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title_fullStr Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title_full_unstemmed Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title_short Fracture Immobilization in an Austere Environment: A Comparative Study of Military Special Operations Medical Personnel using a SAM Splint vs a One-Step Spray on Foam
title_sort fracture immobilization in an austere environment: a comparative study of military special operations medical personnel using a sam splint vs a one-step spray on foam
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696418/
http://dx.doi.org/10.1177/2473011419S00297
work_keys_str_mv AT martinkevind fractureimmobilizationinanaustereenvironmentacomparativestudyofmilitaryspecialoperationsmedicalpersonnelusingasamsplintvsaonestepsprayonfoam
AT unangstalicia fractureimmobilizationinanaustereenvironmentacomparativestudyofmilitaryspecialoperationsmedicalpersonnelusingasamsplintvsaonestepsprayonfoam
AT chisholmjaime fractureimmobilizationinanaustereenvironmentacomparativestudyofmilitaryspecialoperationsmedicalpersonnelusingasamsplintvsaonestepsprayonfoam