Cargando…
An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy
CATEGORY: Ankle, Ankle Arthritis INTRODUCTION/PURPOSE: Ankle replacements (TAR) have evolved significantly over the past 10 years. While most TAR systems reference the medial gutter to set axial tibial component rotation, newer CT scan-based patient specific instrumentation (PSI) allows any rotation...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696756/ http://dx.doi.org/10.1177/2473011419S00180 |
_version_ | 1784619887408185344 |
---|---|
author | Gagne, Oliver J. Veljkovic, Andrea Townshend, Dave Younger, Alastair S.E. Wing, Kevin J. Penner, Murray J. |
author_facet | Gagne, Oliver J. Veljkovic, Andrea Townshend, Dave Younger, Alastair S.E. Wing, Kevin J. Penner, Murray J. |
author_sort | Gagne, Oliver J. |
collection | PubMed |
description | CATEGORY: Ankle, Ankle Arthritis INTRODUCTION/PURPOSE: Ankle replacements (TAR) have evolved significantly over the past 10 years. While most TAR systems reference the medial gutter to set axial tibial component rotation, newer CT scan-based patient specific instrumentation (PSI) allows any rotational position to be set, and this is commonly set to bisect the medial and lateral gutter lines. It is still not yet known which alignment technique is optimal. METHODS: We initiated a prospective cohort analysis of 22 consecutive cases using the Prophecy® 3D PSI guide (Wright Medical Technologies, Memphis, TN). There were four foot and ankle fellowship trained surgeons practicing from two referral centers. Every procedure had an intra-operative photograph taken from the knee looking down to the ankle after both the attachment of the PSI guide to the tibia and the insertion of the standard medial gutter fork. The axial rotational angle between both was measured and compared to the Prophecy® pre-operative plan. Statistical analysis was performed using the student’s T-test for paired distribution and descriptive statistics given the number of cases (N=22). RESULTS: The primary outcome of this study was to assess the correlation between the pre-operative medial gutter line drawn on the Prophecy plan and the intra-operative medial gutter fork angle. The Pearson R correlation value was 0.54 (p = 0.53). The average difference between the pre-operative medial gutter line on the Prophecy® plan and the intra-operative gutter fork was -0.46 [95% CI -2.04 – 1.10]. This could mean that the medial gutter fork is on average slightly more internally rotated than templated medial gutter line. However, the average of the absolute differences between the preoperative medial gutter line and the intraoperative medial gutter fork was 2.69 degrees. Of the 22 cases, 11 were within 2 degrees and 17 were within 4 degrees. CONCLUSION: The medial gutter line on Prophecy® PSI pre-operative TAR plans is a moderately good representation of the intra- operative medial gutter fork position used in standard TAR instrumentation. Based on this, using the Prophecy® default which sets the tibial implant axial rotation to bisect the medial and lateral gutter lines will typically lead to greater external rotation of the tibial component compared to standard TAR instrumentation which aligns the tibial component to the medial gutter fork. Further work needs to be done to better understand which of these axial alignment options, or potentially others, is optimal. |
format | Online Article Text |
id | pubmed-8696756 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-86967562022-01-28 An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy Gagne, Oliver J. Veljkovic, Andrea Townshend, Dave Younger, Alastair S.E. Wing, Kevin J. Penner, Murray J. Foot Ankle Orthop Article CATEGORY: Ankle, Ankle Arthritis INTRODUCTION/PURPOSE: Ankle replacements (TAR) have evolved significantly over the past 10 years. While most TAR systems reference the medial gutter to set axial tibial component rotation, newer CT scan-based patient specific instrumentation (PSI) allows any rotational position to be set, and this is commonly set to bisect the medial and lateral gutter lines. It is still not yet known which alignment technique is optimal. METHODS: We initiated a prospective cohort analysis of 22 consecutive cases using the Prophecy® 3D PSI guide (Wright Medical Technologies, Memphis, TN). There were four foot and ankle fellowship trained surgeons practicing from two referral centers. Every procedure had an intra-operative photograph taken from the knee looking down to the ankle after both the attachment of the PSI guide to the tibia and the insertion of the standard medial gutter fork. The axial rotational angle between both was measured and compared to the Prophecy® pre-operative plan. Statistical analysis was performed using the student’s T-test for paired distribution and descriptive statistics given the number of cases (N=22). RESULTS: The primary outcome of this study was to assess the correlation between the pre-operative medial gutter line drawn on the Prophecy plan and the intra-operative medial gutter fork angle. The Pearson R correlation value was 0.54 (p = 0.53). The average difference between the pre-operative medial gutter line on the Prophecy® plan and the intra-operative gutter fork was -0.46 [95% CI -2.04 – 1.10]. This could mean that the medial gutter fork is on average slightly more internally rotated than templated medial gutter line. However, the average of the absolute differences between the preoperative medial gutter line and the intraoperative medial gutter fork was 2.69 degrees. Of the 22 cases, 11 were within 2 degrees and 17 were within 4 degrees. CONCLUSION: The medial gutter line on Prophecy® PSI pre-operative TAR plans is a moderately good representation of the intra- operative medial gutter fork position used in standard TAR instrumentation. Based on this, using the Prophecy® default which sets the tibial implant axial rotation to bisect the medial and lateral gutter lines will typically lead to greater external rotation of the tibial component compared to standard TAR instrumentation which aligns the tibial component to the medial gutter fork. Further work needs to be done to better understand which of these axial alignment options, or potentially others, is optimal. SAGE Publications 2019-10-28 /pmc/articles/PMC8696756/ http://dx.doi.org/10.1177/2473011419S00180 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Gagne, Oliver J. Veljkovic, Andrea Townshend, Dave Younger, Alastair S.E. Wing, Kevin J. Penner, Murray J. An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title | An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title_full | An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title_fullStr | An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title_full_unstemmed | An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title_short | An Intra-Operative Assessment of the Axial Rotational Positioning of the Tibial Component Using Patient-Specific Instrumentation Prophecy |
title_sort | intra-operative assessment of the axial rotational positioning of the tibial component using patient-specific instrumentation prophecy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8696756/ http://dx.doi.org/10.1177/2473011419S00180 |
work_keys_str_mv | AT gagneoliverj anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT veljkovicandrea anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT townshenddave anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT youngeralastairse anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT wingkevinj anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT pennermurrayj anintraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT gagneoliverj intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT veljkovicandrea intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT townshenddave intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT youngeralastairse intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT wingkevinj intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy AT pennermurrayj intraoperativeassessmentoftheaxialrotationalpositioningofthetibialcomponentusingpatientspecificinstrumentationprophecy |