Cargando…
2D Analysis of Gold Weight Implantation Surgery Results in Paralytic Lagophthalmos
OBJECTIVES: Gold weight implantation in the upper eyelid is a frequently performed treatment for paralytic lagophthalmos to prevent corneal exposure. A margin reflex distance of -1 and -2 (MRD1, MRD2), the palpebral fissure height (PFH), and the vertical lagophthalmos (LV) are 1-dimensional (1D) mea...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697052/ https://www.ncbi.nlm.nih.gov/pubmed/35005516 http://dx.doi.org/10.14744/bej.2021.95866 |
Sumario: | OBJECTIVES: Gold weight implantation in the upper eyelid is a frequently performed treatment for paralytic lagophthalmos to prevent corneal exposure. A margin reflex distance of -1 and -2 (MRD1, MRD2), the palpebral fissure height (PFH), and the vertical lagophthalmos (LV) are 1-dimensional (1D) measurements used in follow-up. Because the exposure area is 2-dimensional (2D), this study was designed to investigate the results using both 1D and 2D analysis. METHODS: Ten patients who underwent pretarsal suborbicularis oculi gold weight implantation were included in the study. Photographs were taken with a digital camera and the images were analyzed using ImageJ software (US National Institutes of Health, Bethesda, MD, USA). The lagophthalmos area (LA) and ocular surface area (OSA) were measured in 2D in addition to the MRD1, MRD2, PFH, LV. Preoperative and postoperative values were compared using the Wilcoxon signed-rank test. Associations between parameters were evaluated using Spearman's correlation analysis. RESULTS: The mean age of the patients (7 male, 3 female) was 39.6±16.4 years (range: 14–60 years). The mean implant weight was 1.46 g (0.8–1.6 g). There were significant reductions in the MRD1, MRD2, PFH, OSA, LV, and LA values after surgery (p<0.05). The weight of the gold implant had a strong correlation with the PFH, OSA, MRD1, and MRD2, but not the LV or LA, preoperatively. The OSA was strongly correlated with the MRD1, PFH, and the implant weight, but not the MRD2. The LA was strongly correlated with the LV, preoperatively. In the postoperative period, the OSA was strongly correlated with the PFH and the MRD2 but not the MRD1, while the LA was strongly correlated with the LV, MRD1, and the PFH. CONCLUSION: It is easy to obtain 2D measurements using digital image analysis software, and they proved to be accurate and correlated strongly with 1D measurements. The OSA and LA measurements were significantly lower following upper eyelid gold weight implantation. The PFH and LV were compatible with the OSA and LA, preoperatively. |
---|