Cargando…

Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery

CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus correction is often complicated by recurrence in the setting of inadequate soft tissue balancing. The etiology of recurrence is multifactorial, but a key factor is the quality of the medial capsulorrhaphy which is limited by the quality and streng...

Descripción completa

Detalles Bibliográficos
Autores principales: Miller, Christopher P., Paulus, Megan, Kreulen, Christopher, Harris, Thomas, Giza, Eric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697129/
http://dx.doi.org/10.1177/2473011419S00303
_version_ 1784619977988374528
author Miller, Christopher P.
Paulus, Megan
Kreulen, Christopher
Harris, Thomas
Giza, Eric
author_facet Miller, Christopher P.
Paulus, Megan
Kreulen, Christopher
Harris, Thomas
Giza, Eric
author_sort Miller, Christopher P.
collection PubMed
description CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus correction is often complicated by recurrence in the setting of inadequate soft tissue balancing. The etiology of recurrence is multifactorial, but a key factor is the quality of the medial capsulorrhaphy which is limited by the quality and strength of the soft tissues. These soft tissues are often attenuated with loss of integrity due to the longstanding bunion deformity. We hypothesize that the medial capsulorrhaphy augmented with a suture tape construct will create a stronger repair. METHODS: 8 unmatched and 16 matched cadaveric foot specimens were prepared. None had bunion deformities. The 8 unmatched samples were tested to determine the strength of the native medial capsule. The 16 matched samples underwent a longitudinal medial capsulotomy, eminence resection and medial capsulorrhaphy with or without augmentation with a suture tape construct. The samples were then tested in a biomechanics lab to determine the strength of the medial capsulorrhaphy. RESULTS: The mean maximum moment for the intact, capsular repair and suture tape groups were 2.19 ± 0.639 Nm, 0.225 ± 0.074 Nm and 0.968 ± 0.581, respectively, P<0.001. The mean stiffness for the intact, capsular repair and suture tape groups were 8.06 ± 3.75 N/mm, 1.463 ± 0.553 N/mm, and 4.438 ± 4.035 N/mm, respectively, P=0.003. The suture tape provided 4.3x higher maximum moment and 3x higher stiffness compared to traditional medial capsulorrhaphy. CONCLUSION: The study demonstrates that a medial capsular repair augmented in a cadaveric model of medial capsulorrhaphy to provide greater strength compared to conventional suture repair. Recurrence of hallux valgus after surgery is multifactorial. One element is the strength of the medial imbrication and capsular repair at the 1st metatarsal phalangeal joint (MTPJ). The study presents biomechanical data demonstrating that this repair is strengthened with suture tape augmentation at the medial 1st MTPJ. This may result in decreased recurrence and potentially improved patient satisfaction following bunion correction.
format Online
Article
Text
id pubmed-8697129
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-86971292022-01-28 Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery Miller, Christopher P. Paulus, Megan Kreulen, Christopher Harris, Thomas Giza, Eric Foot Ankle Orthop Article CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus correction is often complicated by recurrence in the setting of inadequate soft tissue balancing. The etiology of recurrence is multifactorial, but a key factor is the quality of the medial capsulorrhaphy which is limited by the quality and strength of the soft tissues. These soft tissues are often attenuated with loss of integrity due to the longstanding bunion deformity. We hypothesize that the medial capsulorrhaphy augmented with a suture tape construct will create a stronger repair. METHODS: 8 unmatched and 16 matched cadaveric foot specimens were prepared. None had bunion deformities. The 8 unmatched samples were tested to determine the strength of the native medial capsule. The 16 matched samples underwent a longitudinal medial capsulotomy, eminence resection and medial capsulorrhaphy with or without augmentation with a suture tape construct. The samples were then tested in a biomechanics lab to determine the strength of the medial capsulorrhaphy. RESULTS: The mean maximum moment for the intact, capsular repair and suture tape groups were 2.19 ± 0.639 Nm, 0.225 ± 0.074 Nm and 0.968 ± 0.581, respectively, P<0.001. The mean stiffness for the intact, capsular repair and suture tape groups were 8.06 ± 3.75 N/mm, 1.463 ± 0.553 N/mm, and 4.438 ± 4.035 N/mm, respectively, P=0.003. The suture tape provided 4.3x higher maximum moment and 3x higher stiffness compared to traditional medial capsulorrhaphy. CONCLUSION: The study demonstrates that a medial capsular repair augmented in a cadaveric model of medial capsulorrhaphy to provide greater strength compared to conventional suture repair. Recurrence of hallux valgus after surgery is multifactorial. One element is the strength of the medial imbrication and capsular repair at the 1st metatarsal phalangeal joint (MTPJ). The study presents biomechanical data demonstrating that this repair is strengthened with suture tape augmentation at the medial 1st MTPJ. This may result in decreased recurrence and potentially improved patient satisfaction following bunion correction. SAGE Publications 2019-10-28 /pmc/articles/PMC8697129/ http://dx.doi.org/10.1177/2473011419S00303 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Miller, Christopher P.
Paulus, Megan
Kreulen, Christopher
Harris, Thomas
Giza, Eric
Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title_full Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title_fullStr Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title_full_unstemmed Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title_short Biomechanical Evaluation of an Augmented Medial Capsular Repair for Hallux Valgus Surgery
title_sort biomechanical evaluation of an augmented medial capsular repair for hallux valgus surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697129/
http://dx.doi.org/10.1177/2473011419S00303
work_keys_str_mv AT millerchristopherp biomechanicalevaluationofanaugmentedmedialcapsularrepairforhalluxvalgussurgery
AT paulusmegan biomechanicalevaluationofanaugmentedmedialcapsularrepairforhalluxvalgussurgery
AT kreulenchristopher biomechanicalevaluationofanaugmentedmedialcapsularrepairforhalluxvalgussurgery
AT harristhomas biomechanicalevaluationofanaugmentedmedialcapsularrepairforhalluxvalgussurgery
AT gizaeric biomechanicalevaluationofanaugmentedmedialcapsularrepairforhalluxvalgussurgery