Cargando…

Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct

CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus is a common deformity of the forefoot. There are over 130 procedures described to correct hallux valgus. Classically, the treatment of mild to moderate hallux valgus is with a distal metatarsal osteotomy. A variety of fixation techniques have been...

Descripción completa

Detalles Bibliográficos
Autores principales: Volpi, Alexander, Zbeda, Robert, Katchis, Christopher, Weiner, Lon, Katchis, Stuart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697243/
http://dx.doi.org/10.1177/2473011419S00428
_version_ 1784620006327189504
author Volpi, Alexander
Zbeda, Robert
Katchis, Christopher
Weiner, Lon
Katchis, Stuart
author_facet Volpi, Alexander
Zbeda, Robert
Katchis, Christopher
Weiner, Lon
Katchis, Stuart
author_sort Volpi, Alexander
collection PubMed
description CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus is a common deformity of the forefoot. There are over 130 procedures described to correct hallux valgus. Classically, the treatment of mild to moderate hallux valgus is with a distal metatarsal osteotomy. A variety of fixation techniques have been described for use with this osteotomy most of which require partial or non-weight bearing until the osteotomy is healed. Tension Band fixation is a well-known principle in orthopedic surgery. The goal of the present study is to radiographically assess the maintenance of distal first metatarsal osteotomy fixation using a novel tension band device (Re+Line tension band bunion plate system, Nextremity Solutions) with immediate post-operative weight-bearing. METHODS: The patient database for one surgeon was retrospectively reviewed for patients that underwent hallux valgus correction with the Re+Line tension band device between 2014 and 2017. Postoperative protocol included a soft dressing, firm surgical shoe, and weight-bearing as tolerated with a cane. Patients were excluded if fixation was achieved with something other than a tension band construct. Radiographs were obtained and reviewed retrospectively by 3 authors. Pre and postoperative hallux valgus (HVA) and intermetatarsal angles (IMA) were measured as described previously in the literature, and the changes in correction compared. Maintenance of correction and hardware integrity were assessed at final follow-up after weight bearing as tolerated in a surgical shoe in the postoperative period. Statistical analysis was performed using a Wilcoxon signed-rank test for the changes in HVA and IMA. RESULTS: There was a total of 72 patients and 76 toes that underwent hallux valgus correction with a tension band construct, at a mean follow-up of 4.36 months. 68 of 72 patients were female. The average age was 60.8 years old. The mean preoperative HVA was 27.1 degrees. The mean postoperative HVA was 6.14 degrees, with a mean correction of 20.22 degrees (p<0.001). The mean preoperative IMA was 14.14 degrees. The mean postoperative IMA was 6.10 degrees, with a mean correction of 7.98 degrees (p<0.001). There was loss of reduction found in 6 of 76 toes (7.89%).There were zero cases of hardware failure. All osteotomies healed at final follow-up. CONCLUSION: This study shows successful radiographic outcome after hallux valgus correction using a tension band construct and allowing immediate full weight-bearing in a surgical shoe in the postoperative period. Significant deformity correction was achieved and maintained and all osteotomies healed. The Re+Line tension band bunion correction system can be safely used as a successful option to fix distal first metatarsal osteotomies, while allowing patients to fully weight bear in a surgical shoe postoperatively and potentially return to activities faster than when using traditional fixation methods. Future studies are needed to assess functional outcomes and patient satisfaction with this novel technique.
format Online
Article
Text
id pubmed-8697243
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-86972432022-01-28 Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct Volpi, Alexander Zbeda, Robert Katchis, Christopher Weiner, Lon Katchis, Stuart Foot Ankle Orthop Article CATEGORY: Bunion INTRODUCTION/PURPOSE: Hallux valgus is a common deformity of the forefoot. There are over 130 procedures described to correct hallux valgus. Classically, the treatment of mild to moderate hallux valgus is with a distal metatarsal osteotomy. A variety of fixation techniques have been described for use with this osteotomy most of which require partial or non-weight bearing until the osteotomy is healed. Tension Band fixation is a well-known principle in orthopedic surgery. The goal of the present study is to radiographically assess the maintenance of distal first metatarsal osteotomy fixation using a novel tension band device (Re+Line tension band bunion plate system, Nextremity Solutions) with immediate post-operative weight-bearing. METHODS: The patient database for one surgeon was retrospectively reviewed for patients that underwent hallux valgus correction with the Re+Line tension band device between 2014 and 2017. Postoperative protocol included a soft dressing, firm surgical shoe, and weight-bearing as tolerated with a cane. Patients were excluded if fixation was achieved with something other than a tension band construct. Radiographs were obtained and reviewed retrospectively by 3 authors. Pre and postoperative hallux valgus (HVA) and intermetatarsal angles (IMA) were measured as described previously in the literature, and the changes in correction compared. Maintenance of correction and hardware integrity were assessed at final follow-up after weight bearing as tolerated in a surgical shoe in the postoperative period. Statistical analysis was performed using a Wilcoxon signed-rank test for the changes in HVA and IMA. RESULTS: There was a total of 72 patients and 76 toes that underwent hallux valgus correction with a tension band construct, at a mean follow-up of 4.36 months. 68 of 72 patients were female. The average age was 60.8 years old. The mean preoperative HVA was 27.1 degrees. The mean postoperative HVA was 6.14 degrees, with a mean correction of 20.22 degrees (p<0.001). The mean preoperative IMA was 14.14 degrees. The mean postoperative IMA was 6.10 degrees, with a mean correction of 7.98 degrees (p<0.001). There was loss of reduction found in 6 of 76 toes (7.89%).There were zero cases of hardware failure. All osteotomies healed at final follow-up. CONCLUSION: This study shows successful radiographic outcome after hallux valgus correction using a tension band construct and allowing immediate full weight-bearing in a surgical shoe in the postoperative period. Significant deformity correction was achieved and maintained and all osteotomies healed. The Re+Line tension band bunion correction system can be safely used as a successful option to fix distal first metatarsal osteotomies, while allowing patients to fully weight bear in a surgical shoe postoperatively and potentially return to activities faster than when using traditional fixation methods. Future studies are needed to assess functional outcomes and patient satisfaction with this novel technique. SAGE Publications 2019-10-28 /pmc/articles/PMC8697243/ http://dx.doi.org/10.1177/2473011419S00428 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Volpi, Alexander
Zbeda, Robert
Katchis, Christopher
Weiner, Lon
Katchis, Stuart
Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title_full Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title_fullStr Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title_full_unstemmed Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title_short Radiographic Outcomes after Fixation of Distal Metatarsal Osteotomy for Hallux Valgus Using a Tension Band Construct
title_sort radiographic outcomes after fixation of distal metatarsal osteotomy for hallux valgus using a tension band construct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697243/
http://dx.doi.org/10.1177/2473011419S00428
work_keys_str_mv AT volpialexander radiographicoutcomesafterfixationofdistalmetatarsalosteotomyforhalluxvalgususingatensionbandconstruct
AT zbedarobert radiographicoutcomesafterfixationofdistalmetatarsalosteotomyforhalluxvalgususingatensionbandconstruct
AT katchischristopher radiographicoutcomesafterfixationofdistalmetatarsalosteotomyforhalluxvalgususingatensionbandconstruct
AT weinerlon radiographicoutcomesafterfixationofdistalmetatarsalosteotomyforhalluxvalgususingatensionbandconstruct
AT katchisstuart radiographicoutcomesafterfixationofdistalmetatarsalosteotomyforhalluxvalgususingatensionbandconstruct