Cargando…
The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer
A comprehensive assessment of a polytetrafluoroethylene (PTFE) hollow fiber membrane contactor and ultrasound for intensifying ozone–liquid mass transfer was conducted simultaneously. The initial part of the study concentrates on the systematic analysis of the previous literature related to the rein...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697726/ https://www.ncbi.nlm.nih.gov/pubmed/35423921 http://dx.doi.org/10.1039/d1ra00452b |
_version_ | 1784620108490997760 |
---|---|
author | Wang, Bing Zhang, Huan Meng, Qingjie Ren, Hongyang Xiong, Mingyang Gao, Chunyang |
author_facet | Wang, Bing Zhang, Huan Meng, Qingjie Ren, Hongyang Xiong, Mingyang Gao, Chunyang |
author_sort | Wang, Bing |
collection | PubMed |
description | A comprehensive assessment of a polytetrafluoroethylene (PTFE) hollow fiber membrane contactor and ultrasound for intensifying ozone–liquid mass transfer was conducted simultaneously. The initial part of the study concentrates on the systematic analysis of the previous literature related to the reinforcement on the ozone–liquid mass transfer. In this paper, the introduction of a membrane contactor and ultrasound as a catalyzer that increased the mass transfer coefficient (K(L)a) may be partially attributed to the increase of the net surface area and the decrease of the mass transfer resistance, thus leading to the enhancement of the ozone mass transfer rate and acceleration of the ozone decomposition in solution. Results revealed that the maximum value of the K(L)a value was 0.7858 min(−1) in the PTFE hollow fiber membrane contactor in the presence of the ultrasound, while only 0.5154 min(−1) in a single ozone aeration at an intake flow of 300 L h(−1), ozone dosage of 32.38 mg L(−1) and operating temperature of 293.15 K. A 52.46% improvement of the K(L)a value was obtained in the presence of the ultrasound. In addition, the dosage of sodium chloride appeared to have a positive correlation with K(L)a, but a negative correlation with the concentration of dissolved ozone. The sulfolane destruction by ozonation, ultrasound and the combination between the ozonation and ultrasound were performed to further verify the enhancement of the ozone mass transfer performance. It has been established that the O(3)/US combined process was a promising method, giving the maximum degradation of sulfolane (96.5%) with the synergistic index as 2.41. |
format | Online Article Text |
id | pubmed-8697726 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-86977262022-04-13 The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer Wang, Bing Zhang, Huan Meng, Qingjie Ren, Hongyang Xiong, Mingyang Gao, Chunyang RSC Adv Chemistry A comprehensive assessment of a polytetrafluoroethylene (PTFE) hollow fiber membrane contactor and ultrasound for intensifying ozone–liquid mass transfer was conducted simultaneously. The initial part of the study concentrates on the systematic analysis of the previous literature related to the reinforcement on the ozone–liquid mass transfer. In this paper, the introduction of a membrane contactor and ultrasound as a catalyzer that increased the mass transfer coefficient (K(L)a) may be partially attributed to the increase of the net surface area and the decrease of the mass transfer resistance, thus leading to the enhancement of the ozone mass transfer rate and acceleration of the ozone decomposition in solution. Results revealed that the maximum value of the K(L)a value was 0.7858 min(−1) in the PTFE hollow fiber membrane contactor in the presence of the ultrasound, while only 0.5154 min(−1) in a single ozone aeration at an intake flow of 300 L h(−1), ozone dosage of 32.38 mg L(−1) and operating temperature of 293.15 K. A 52.46% improvement of the K(L)a value was obtained in the presence of the ultrasound. In addition, the dosage of sodium chloride appeared to have a positive correlation with K(L)a, but a negative correlation with the concentration of dissolved ozone. The sulfolane destruction by ozonation, ultrasound and the combination between the ozonation and ultrasound were performed to further verify the enhancement of the ozone mass transfer performance. It has been established that the O(3)/US combined process was a promising method, giving the maximum degradation of sulfolane (96.5%) with the synergistic index as 2.41. The Royal Society of Chemistry 2021-04-14 /pmc/articles/PMC8697726/ /pubmed/35423921 http://dx.doi.org/10.1039/d1ra00452b Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Wang, Bing Zhang, Huan Meng, Qingjie Ren, Hongyang Xiong, Mingyang Gao, Chunyang The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title | The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title_full | The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title_fullStr | The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title_full_unstemmed | The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title_short | The enhancement of ozone–liquid mass transfer performance in a PTFE hollow fiber membrane contactor using ultrasound as a catalyzer |
title_sort | enhancement of ozone–liquid mass transfer performance in a ptfe hollow fiber membrane contactor using ultrasound as a catalyzer |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697726/ https://www.ncbi.nlm.nih.gov/pubmed/35423921 http://dx.doi.org/10.1039/d1ra00452b |
work_keys_str_mv | AT wangbing theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT zhanghuan theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT mengqingjie theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT renhongyang theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT xiongmingyang theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT gaochunyang theenhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT wangbing enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT zhanghuan enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT mengqingjie enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT renhongyang enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT xiongmingyang enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer AT gaochunyang enhancementofozoneliquidmasstransferperformanceinaptfehollowfibermembranecontactorusingultrasoundasacatalyzer |