Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8698921/ https://www.ncbi.nlm.nih.gov/pubmed/34943178 http://dx.doi.org/10.3390/biology10121263 |
_version_ | 1784620394085351424 |
---|---|
author | Antunes, Madalena Quental, Carlos Folgado, João de Campos Azevedo, Clara Ângelo, Ana Catarina |
author_facet | Antunes, Madalena Quental, Carlos Folgado, João de Campos Azevedo, Clara Ângelo, Ana Catarina |
author_sort | Antunes, Madalena |
collection | PubMed |
description | SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the kinematics of the shoulder. The shoulder position during fixation of the graft may be a key factor impacting the outcome of ASCR; however, biomechanical evidence is lacking, as most studies addressing ASCR have been conducted in cadavers. In this study, graft strain and glenohumeral joint reaction force, estimated using a 3-D musculoskeletal model of the upper limb, were used to evaluate graft integrity and shoulder stability, respectively. The results suggest that ASCR significantly improved shoulder stability compared to the preoperative condition; however, the shoulder positions of fixation associated with the greatest improvements were also associated with the highest risk of compromising the integrity of the graft due to high strains. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. ABSTRACT: The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. |
format | Online Article Text |
id | pubmed-8698921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86989212021-12-24 Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability Antunes, Madalena Quental, Carlos Folgado, João de Campos Azevedo, Clara Ângelo, Ana Catarina Biology (Basel) Article SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the kinematics of the shoulder. The shoulder position during fixation of the graft may be a key factor impacting the outcome of ASCR; however, biomechanical evidence is lacking, as most studies addressing ASCR have been conducted in cadavers. In this study, graft strain and glenohumeral joint reaction force, estimated using a 3-D musculoskeletal model of the upper limb, were used to evaluate graft integrity and shoulder stability, respectively. The results suggest that ASCR significantly improved shoulder stability compared to the preoperative condition; however, the shoulder positions of fixation associated with the greatest improvements were also associated with the highest risk of compromising the integrity of the graft due to high strains. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. ABSTRACT: The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. MDPI 2021-12-03 /pmc/articles/PMC8698921/ /pubmed/34943178 http://dx.doi.org/10.3390/biology10121263 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Antunes, Madalena Quental, Carlos Folgado, João de Campos Azevedo, Clara Ângelo, Ana Catarina Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title | Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title_full | Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title_fullStr | Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title_full_unstemmed | Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title_short | Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability |
title_sort | shoulder positioning during superior capsular reconstruction: computational analysis of graft integrity and shoulder stability |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8698921/ https://www.ncbi.nlm.nih.gov/pubmed/34943178 http://dx.doi.org/10.3390/biology10121263 |
work_keys_str_mv | AT antunesmadalena shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability AT quentalcarlos shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability AT folgadojoao shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability AT decamposazevedoclara shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability AT angeloanacatarina shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability |