Cargando…

Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability

SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the...

Descripción completa

Detalles Bibliográficos
Autores principales: Antunes, Madalena, Quental, Carlos, Folgado, João, de Campos Azevedo, Clara, Ângelo, Ana Catarina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8698921/
https://www.ncbi.nlm.nih.gov/pubmed/34943178
http://dx.doi.org/10.3390/biology10121263
_version_ 1784620394085351424
author Antunes, Madalena
Quental, Carlos
Folgado, João
de Campos Azevedo, Clara
Ângelo, Ana Catarina
author_facet Antunes, Madalena
Quental, Carlos
Folgado, João
de Campos Azevedo, Clara
Ângelo, Ana Catarina
author_sort Antunes, Madalena
collection PubMed
description SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the kinematics of the shoulder. The shoulder position during fixation of the graft may be a key factor impacting the outcome of ASCR; however, biomechanical evidence is lacking, as most studies addressing ASCR have been conducted in cadavers. In this study, graft strain and glenohumeral joint reaction force, estimated using a 3-D musculoskeletal model of the upper limb, were used to evaluate graft integrity and shoulder stability, respectively. The results suggest that ASCR significantly improved shoulder stability compared to the preoperative condition; however, the shoulder positions of fixation associated with the greatest improvements were also associated with the highest risk of compromising the integrity of the graft due to high strains. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. ABSTRACT: The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft.
format Online
Article
Text
id pubmed-8698921
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86989212021-12-24 Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability Antunes, Madalena Quental, Carlos Folgado, João de Campos Azevedo, Clara Ângelo, Ana Catarina Biology (Basel) Article SIMPLE SUMMARY: In arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs), a graft is positioned and fixed between the superior rim of the glenoid and the humeral supraspinatus footprint. The fixation of the graft aims to restore the stability and improve the kinematics of the shoulder. The shoulder position during fixation of the graft may be a key factor impacting the outcome of ASCR; however, biomechanical evidence is lacking, as most studies addressing ASCR have been conducted in cadavers. In this study, graft strain and glenohumeral joint reaction force, estimated using a 3-D musculoskeletal model of the upper limb, were used to evaluate graft integrity and shoulder stability, respectively. The results suggest that ASCR significantly improved shoulder stability compared to the preoperative condition; however, the shoulder positions of fixation associated with the greatest improvements were also associated with the highest risk of compromising the integrity of the graft due to high strains. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. ABSTRACT: The shoulder position during fixation of the graft may be a key factor impacting the outcome of arthroscopic superior capsular reconstruction (ASCR) in irreparable rotator cuff tears (IRCTs). However, biomechanical evidence regarding this effect is lacking. The aim of this study was to evaluate the influence of the shoulder position during fixation of the graft on shoulder stability and graft tear risk in ASCR. A 3-D musculoskeletal model of the upper limb was modified to account for the fixation of the graft in ASCR, assuming a full-thickness tear of the supraspinatus tendon. The concomitant tenotomy of the long head of the biceps (LHB) tendon was also studied. The biomechanical parameters evaluated included the strain of the graft and the glenohumeral joint reaction force (GH JRF), which were used to evaluate graft integrity and shoulder stability, respectively. Fixation of the graft considering abduction angles greater than 15° resulted in a high risk for graft tearing when the arm was adducted to the side of the trunk. For abduction angles below 15°, the mean shoulder stability improved significantly, ranging between 6% and 20% (p < 0.001), compared with that in the preoperative condition. The concomitant tenotomy of the LHB tendon resulted in loss of stability when compared to ASCR with an intact LHB tendon. The position of the shoulder during fixation of the graft has a significant effect on shoulder stability and graft tear risk after ASCR in IRCTs. This study provides new and important information regarding the role of shoulder positioning during fixation of the graft. MDPI 2021-12-03 /pmc/articles/PMC8698921/ /pubmed/34943178 http://dx.doi.org/10.3390/biology10121263 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Antunes, Madalena
Quental, Carlos
Folgado, João
de Campos Azevedo, Clara
Ângelo, Ana Catarina
Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title_full Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title_fullStr Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title_full_unstemmed Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title_short Shoulder Positioning during Superior Capsular Reconstruction: Computational Analysis of Graft Integrity and Shoulder Stability
title_sort shoulder positioning during superior capsular reconstruction: computational analysis of graft integrity and shoulder stability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8698921/
https://www.ncbi.nlm.nih.gov/pubmed/34943178
http://dx.doi.org/10.3390/biology10121263
work_keys_str_mv AT antunesmadalena shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability
AT quentalcarlos shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability
AT folgadojoao shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability
AT decamposazevedoclara shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability
AT angeloanacatarina shoulderpositioningduringsuperiorcapsularreconstructioncomputationalanalysisofgraftintegrityandshoulderstability