Cargando…
On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer inter...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699405/ https://www.ncbi.nlm.nih.gov/pubmed/34940273 http://dx.doi.org/10.3390/bios11120516 |
_version_ | 1784620504934514688 |
---|---|
author | Bian, Sumin Tao, Ying Zhu, Zhoule Zhu, Peixi Wang, Qiqin Wu, Hemmings Sawan, Mohamad |
author_facet | Bian, Sumin Tao, Ying Zhu, Zhoule Zhu, Peixi Wang, Qiqin Wu, Hemmings Sawan, Mohamad |
author_sort | Bian, Sumin |
collection | PubMed |
description | On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3′-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes. |
format | Online Article Text |
id | pubmed-8699405 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86994052021-12-24 On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients Bian, Sumin Tao, Ying Zhu, Zhoule Zhu, Peixi Wang, Qiqin Wu, Hemmings Sawan, Mohamad Biosensors (Basel) Article On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3′-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes. MDPI 2021-12-15 /pmc/articles/PMC8699405/ /pubmed/34940273 http://dx.doi.org/10.3390/bios11120516 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bian, Sumin Tao, Ying Zhu, Zhoule Zhu, Peixi Wang, Qiqin Wu, Hemmings Sawan, Mohamad On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title | On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title_full | On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title_fullStr | On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title_full_unstemmed | On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title_short | On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients |
title_sort | on-site biolayer interferometry-based biosensing of carbamazepine in whole blood of epileptic patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699405/ https://www.ncbi.nlm.nih.gov/pubmed/34940273 http://dx.doi.org/10.3390/bios11120516 |
work_keys_str_mv | AT biansumin onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT taoying onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT zhuzhoule onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT zhupeixi onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT wangqiqin onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT wuhemmings onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients AT sawanmohamad onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients |