Cargando…

On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients

On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer inter...

Descripción completa

Detalles Bibliográficos
Autores principales: Bian, Sumin, Tao, Ying, Zhu, Zhoule, Zhu, Peixi, Wang, Qiqin, Wu, Hemmings, Sawan, Mohamad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699405/
https://www.ncbi.nlm.nih.gov/pubmed/34940273
http://dx.doi.org/10.3390/bios11120516
_version_ 1784620504934514688
author Bian, Sumin
Tao, Ying
Zhu, Zhoule
Zhu, Peixi
Wang, Qiqin
Wu, Hemmings
Sawan, Mohamad
author_facet Bian, Sumin
Tao, Ying
Zhu, Zhoule
Zhu, Peixi
Wang, Qiqin
Wu, Hemmings
Sawan, Mohamad
author_sort Bian, Sumin
collection PubMed
description On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3′-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes.
format Online
Article
Text
id pubmed-8699405
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86994052021-12-24 On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients Bian, Sumin Tao, Ying Zhu, Zhoule Zhu, Peixi Wang, Qiqin Wu, Hemmings Sawan, Mohamad Biosensors (Basel) Article On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3′-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes. MDPI 2021-12-15 /pmc/articles/PMC8699405/ /pubmed/34940273 http://dx.doi.org/10.3390/bios11120516 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bian, Sumin
Tao, Ying
Zhu, Zhoule
Zhu, Peixi
Wang, Qiqin
Wu, Hemmings
Sawan, Mohamad
On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title_full On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title_fullStr On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title_full_unstemmed On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title_short On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients
title_sort on-site biolayer interferometry-based biosensing of carbamazepine in whole blood of epileptic patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699405/
https://www.ncbi.nlm.nih.gov/pubmed/34940273
http://dx.doi.org/10.3390/bios11120516
work_keys_str_mv AT biansumin onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT taoying onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT zhuzhoule onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT zhupeixi onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT wangqiqin onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT wuhemmings onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients
AT sawanmohamad onsitebiolayerinterferometrybasedbiosensingofcarbamazepineinwholebloodofepilepticpatients