Cargando…

Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification

In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structur...

Descripción completa

Detalles Bibliográficos
Autores principales: Yue, Wei, Kim, Eun-Seong, Zhu, Bao-Hua, Chen, Jian, Liang, Jun-Ge, Kim, Nam-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699625/
https://www.ncbi.nlm.nih.gov/pubmed/34940265
http://dx.doi.org/10.3390/bios11120508
_version_ 1784620558324858880
author Yue, Wei
Kim, Eun-Seong
Zhu, Bao-Hua
Chen, Jian
Liang, Jun-Ge
Kim, Nam-Young
author_facet Yue, Wei
Kim, Eun-Seong
Zhu, Bao-Hua
Chen, Jian
Liang, Jun-Ge
Kim, Nam-Young
author_sort Yue, Wei
collection PubMed
description In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration ([Formula: see text]), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25–300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor.
format Online
Article
Text
id pubmed-8699625
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86996252021-12-24 Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification Yue, Wei Kim, Eun-Seong Zhu, Bao-Hua Chen, Jian Liang, Jun-Ge Kim, Nam-Young Biosensors (Basel) Article In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration ([Formula: see text]), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25–300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor. MDPI 2021-12-09 /pmc/articles/PMC8699625/ /pubmed/34940265 http://dx.doi.org/10.3390/bios11120508 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yue, Wei
Kim, Eun-Seong
Zhu, Bao-Hua
Chen, Jian
Liang, Jun-Ge
Kim, Nam-Young
Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title_full Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title_fullStr Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title_full_unstemmed Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title_short Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
title_sort permittivity-inspired microwave resonator-based biosensor based on integrated passive device technology for glucose identification
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699625/
https://www.ncbi.nlm.nih.gov/pubmed/34940265
http://dx.doi.org/10.3390/bios11120508
work_keys_str_mv AT yuewei permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification
AT kimeunseong permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification
AT zhubaohua permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification
AT chenjian permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification
AT liangjunge permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification
AT kimnamyoung permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification