Cargando…
Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification
In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structur...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699625/ https://www.ncbi.nlm.nih.gov/pubmed/34940265 http://dx.doi.org/10.3390/bios11120508 |
_version_ | 1784620558324858880 |
---|---|
author | Yue, Wei Kim, Eun-Seong Zhu, Bao-Hua Chen, Jian Liang, Jun-Ge Kim, Nam-Young |
author_facet | Yue, Wei Kim, Eun-Seong Zhu, Bao-Hua Chen, Jian Liang, Jun-Ge Kim, Nam-Young |
author_sort | Yue, Wei |
collection | PubMed |
description | In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration ([Formula: see text]), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25–300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor. |
format | Online Article Text |
id | pubmed-8699625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86996252021-12-24 Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification Yue, Wei Kim, Eun-Seong Zhu, Bao-Hua Chen, Jian Liang, Jun-Ge Kim, Nam-Young Biosensors (Basel) Article In this study, we propose a high-performance resonator-based biosensor for mediator-free glucose identification. The biosensor is characterized by an air-bridge capacitor and fabricated via integrated passive device technology on gallium arsenide (GaAs) substrate. The exterior design of the structure is a spiral inductor with the air-bridge providing a sensitive surface, whereas the internal capacitor improves indicator performance. The sensing relies on repolarization and rearrangement of surface molecules, which are excited by the dropped sample at the microcosmic level, and the resonance performance variation corresponds to the difference in glucose concentration at the macroscopic level. The air-bridge capacitor in the modeled RLC circuit serves as a bio-recognition element to glucose concentration ([Formula: see text]), generating resonant frequency shifts at 0.874 GHz and 1.244 GHz for concentrations of 25 mg/dL and 300 mg/dL compared to DI water, respectively. The proposed biosensor exhibits excellent sensitivity at 1.38 MHz per mg/dL with a wide detection range for glucose concentrations of 25–300 mg/dL and a low detection limit of 24.59 mg/dL. Additionally, the frequency shift and concentration are highly linear with a coefficient of determination of 0.98823. The response time is less than 3 s. We performed multiple experiments to verify that the surface morphology reveals no deterioration and chemical binding, thus validating the reusability and reliability of the proposed biosensor. MDPI 2021-12-09 /pmc/articles/PMC8699625/ /pubmed/34940265 http://dx.doi.org/10.3390/bios11120508 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yue, Wei Kim, Eun-Seong Zhu, Bao-Hua Chen, Jian Liang, Jun-Ge Kim, Nam-Young Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title | Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title_full | Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title_fullStr | Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title_full_unstemmed | Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title_short | Permittivity-Inspired Microwave Resonator-Based Biosensor Based on Integrated Passive Device Technology for Glucose Identification |
title_sort | permittivity-inspired microwave resonator-based biosensor based on integrated passive device technology for glucose identification |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699625/ https://www.ncbi.nlm.nih.gov/pubmed/34940265 http://dx.doi.org/10.3390/bios11120508 |
work_keys_str_mv | AT yuewei permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification AT kimeunseong permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification AT zhubaohua permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification AT chenjian permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification AT liangjunge permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification AT kimnamyoung permittivityinspiredmicrowaveresonatorbasedbiosensorbasedonintegratedpassivedevicetechnologyforglucoseidentification |