Cargando…
Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks
PURPOSE: To investigate whether ultra-widefield (UWF) swept-source optical coherence tomography (SSOCT) system (Silverstone, Nikon Healthcare Japan, Inc, Tokyo, Japan) can obtain OCT images of peripheral retinal degenerations and breaks. METHODS: Thirty-seven eyes of 31 consecutive cases (16 men, 15...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699765/ https://www.ncbi.nlm.nih.gov/pubmed/34983997 http://dx.doi.org/10.2147/OPTH.S350080 |
_version_ | 1784620592617488384 |
---|---|
author | Kurobe, Ryo Hirano, Yoshio Ogura, Shuntaro Yasukawa, Tsutomu Ogura, Yuichiro |
author_facet | Kurobe, Ryo Hirano, Yoshio Ogura, Shuntaro Yasukawa, Tsutomu Ogura, Yuichiro |
author_sort | Kurobe, Ryo |
collection | PubMed |
description | PURPOSE: To investigate whether ultra-widefield (UWF) swept-source optical coherence tomography (SSOCT) system (Silverstone, Nikon Healthcare Japan, Inc, Tokyo, Japan) can obtain OCT images of peripheral retinal degenerations and breaks. METHODS: Thirty-seven eyes of 31 consecutive cases (16 men, 15 women; mean age 51 years) who had peripheral retinal degenerations and underwent a UWF-SSOCT imaging were enrolled. The convenience and usefulness were investigated. RESULTS: In all eyes, OCT images were capable and interpretable without any special techniques. The respective findings on OCT were retinal degeneration in 16 eyes: lattice degeneration in 8 eyes, paving stone degeneration in 4 eyes, and unclassified in 4 eyes, retinal tear in 12 eyes, and retinal hole in 9 eyes. The respective locations of the retinal degenerations or breaks were the posterior pole in 0 eyes, mid-periphery in 23 eyes, and far-periphery in 14 eyes. Fifteen eyes had a rhegmatogenous retinal detachment (RRD), one of which was preoperative and the other 14 eyes were postoperative. A buckle was placed in 8 eyes for RRD repair. Subretinal fluid was observed in 9 of 21 eyes with retinal break or retinal hole. Vitreoretinal traction was observed in 10 of 27 eyes without a history of vitrectomy. Inverted artifacts on OCT images were observed in 20 of 37 eyes, which were not related to the location or axial length, but were supposed to be due to the limited scan depth. CONCLUSION: The UWF-SSOCT system could capture the OCT images of peripheral retinal degenerations and breaks without any special technique. |
format | Online Article Text |
id | pubmed-8699765 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-86997652022-01-03 Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks Kurobe, Ryo Hirano, Yoshio Ogura, Shuntaro Yasukawa, Tsutomu Ogura, Yuichiro Clin Ophthalmol Original Research PURPOSE: To investigate whether ultra-widefield (UWF) swept-source optical coherence tomography (SSOCT) system (Silverstone, Nikon Healthcare Japan, Inc, Tokyo, Japan) can obtain OCT images of peripheral retinal degenerations and breaks. METHODS: Thirty-seven eyes of 31 consecutive cases (16 men, 15 women; mean age 51 years) who had peripheral retinal degenerations and underwent a UWF-SSOCT imaging were enrolled. The convenience and usefulness were investigated. RESULTS: In all eyes, OCT images were capable and interpretable without any special techniques. The respective findings on OCT were retinal degeneration in 16 eyes: lattice degeneration in 8 eyes, paving stone degeneration in 4 eyes, and unclassified in 4 eyes, retinal tear in 12 eyes, and retinal hole in 9 eyes. The respective locations of the retinal degenerations or breaks were the posterior pole in 0 eyes, mid-periphery in 23 eyes, and far-periphery in 14 eyes. Fifteen eyes had a rhegmatogenous retinal detachment (RRD), one of which was preoperative and the other 14 eyes were postoperative. A buckle was placed in 8 eyes for RRD repair. Subretinal fluid was observed in 9 of 21 eyes with retinal break or retinal hole. Vitreoretinal traction was observed in 10 of 27 eyes without a history of vitrectomy. Inverted artifacts on OCT images were observed in 20 of 37 eyes, which were not related to the location or axial length, but were supposed to be due to the limited scan depth. CONCLUSION: The UWF-SSOCT system could capture the OCT images of peripheral retinal degenerations and breaks without any special technique. Dove 2021-12-19 /pmc/articles/PMC8699765/ /pubmed/34983997 http://dx.doi.org/10.2147/OPTH.S350080 Text en © 2021 Kurobe et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Kurobe, Ryo Hirano, Yoshio Ogura, Shuntaro Yasukawa, Tsutomu Ogura, Yuichiro Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title | Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title_full | Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title_fullStr | Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title_full_unstemmed | Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title_short | Ultra-Widefield Swept-Source Optical Coherence Tomography Findings of Peripheral Retinal Degenerations and Breaks |
title_sort | ultra-widefield swept-source optical coherence tomography findings of peripheral retinal degenerations and breaks |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699765/ https://www.ncbi.nlm.nih.gov/pubmed/34983997 http://dx.doi.org/10.2147/OPTH.S350080 |
work_keys_str_mv | AT kuroberyo ultrawidefieldsweptsourceopticalcoherencetomographyfindingsofperipheralretinaldegenerationsandbreaks AT hiranoyoshio ultrawidefieldsweptsourceopticalcoherencetomographyfindingsofperipheralretinaldegenerationsandbreaks AT ogurashuntaro ultrawidefieldsweptsourceopticalcoherencetomographyfindingsofperipheralretinaldegenerationsandbreaks AT yasukawatsutomu ultrawidefieldsweptsourceopticalcoherencetomographyfindingsofperipheralretinaldegenerationsandbreaks AT ogurayuichiro ultrawidefieldsweptsourceopticalcoherencetomographyfindingsofperipheralretinaldegenerationsandbreaks |