Cargando…
Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters
Chlortoluron (3-(3-chloro-p-tolyl)-1,1-dimethyl urea) is an herbicide widely used in substitution to isoproturon to control grass weed in wheat and barley crops. Chlortoluron has been detected in groundwaters for more than 20 years; and dramatic increases in concentrations are observed after intense...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699797/ https://www.ncbi.nlm.nih.gov/pubmed/34940271 http://dx.doi.org/10.3390/bios11120513 |
_version_ | 1784620600123195392 |
---|---|
author | Surribas, Anaïs Barthelmebs, Lise Noguer, Thierry |
author_facet | Surribas, Anaïs Barthelmebs, Lise Noguer, Thierry |
author_sort | Surribas, Anaïs |
collection | PubMed |
description | Chlortoluron (3-(3-chloro-p-tolyl)-1,1-dimethyl urea) is an herbicide widely used in substitution to isoproturon to control grass weed in wheat and barley crops. Chlortoluron has been detected in groundwaters for more than 20 years; and dramatic increases in concentrations are observed after intense rain outbreaks. In this context; we developed an immunosensor for the determination of chlortoluron based on competitive binding of specific monoclonal antibodies on chlortoluron and immobilized biotinylated chlortoluron; followed by electrochemical detection on screen-printed carbon electrodes. The optimized immunosensor exhibited a logarithmic response in the range 0.01–10 µg·L(−1); with a calculated detection limit (LOD) of 22.4 ng·L(−1); which is below the maximum levels allowed by the legislation (0.1 µg·L(−1)). The immunosensor was used for the determination of chlortoluron in natural groundwaters, showing the absence of matrix effects. |
format | Online Article Text |
id | pubmed-8699797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86997972021-12-24 Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters Surribas, Anaïs Barthelmebs, Lise Noguer, Thierry Biosensors (Basel) Article Chlortoluron (3-(3-chloro-p-tolyl)-1,1-dimethyl urea) is an herbicide widely used in substitution to isoproturon to control grass weed in wheat and barley crops. Chlortoluron has been detected in groundwaters for more than 20 years; and dramatic increases in concentrations are observed after intense rain outbreaks. In this context; we developed an immunosensor for the determination of chlortoluron based on competitive binding of specific monoclonal antibodies on chlortoluron and immobilized biotinylated chlortoluron; followed by electrochemical detection on screen-printed carbon electrodes. The optimized immunosensor exhibited a logarithmic response in the range 0.01–10 µg·L(−1); with a calculated detection limit (LOD) of 22.4 ng·L(−1); which is below the maximum levels allowed by the legislation (0.1 µg·L(−1)). The immunosensor was used for the determination of chlortoluron in natural groundwaters, showing the absence of matrix effects. MDPI 2021-12-13 /pmc/articles/PMC8699797/ /pubmed/34940271 http://dx.doi.org/10.3390/bios11120513 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Surribas, Anaïs Barthelmebs, Lise Noguer, Thierry Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title | Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title_full | Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title_fullStr | Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title_full_unstemmed | Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title_short | Monoclonal Antibody-Based Immunosensor for the Electrochemical Detection of Chlortoluron Herbicide in Groundwaters |
title_sort | monoclonal antibody-based immunosensor for the electrochemical detection of chlortoluron herbicide in groundwaters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8699797/ https://www.ncbi.nlm.nih.gov/pubmed/34940271 http://dx.doi.org/10.3390/bios11120513 |
work_keys_str_mv | AT surribasanais monoclonalantibodybasedimmunosensorfortheelectrochemicaldetectionofchlortoluronherbicideingroundwaters AT barthelmebslise monoclonalantibodybasedimmunosensorfortheelectrochemicaldetectionofchlortoluronherbicideingroundwaters AT noguerthierry monoclonalantibodybasedimmunosensorfortheelectrochemicaldetectionofchlortoluronherbicideingroundwaters |