Cargando…

Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals

An aortic dissection, a particular aortic pathology, occurs when blood pushes through a tear between the layers of the aorta and forms a so-called false lumen. Aortic dissection has a low incidence compared to other diseases, but a relatively high mortality that increases with disease progression. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Spindelböck, Tobias, Ranftl, Sascha, von der Linden, Wolfgang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700029/
https://www.ncbi.nlm.nih.gov/pubmed/34945967
http://dx.doi.org/10.3390/e23121661
_version_ 1784620657363910656
author Spindelböck, Tobias
Ranftl, Sascha
von der Linden, Wolfgang
author_facet Spindelböck, Tobias
Ranftl, Sascha
von der Linden, Wolfgang
author_sort Spindelböck, Tobias
collection PubMed
description An aortic dissection, a particular aortic pathology, occurs when blood pushes through a tear between the layers of the aorta and forms a so-called false lumen. Aortic dissection has a low incidence compared to other diseases, but a relatively high mortality that increases with disease progression. An early identification and treatment increases patients’ chances of survival. State-of-the-art medical imaging techniques have several disadvantages; therefore, we propose the detection of aortic dissections through their signatures in impedance cardiography signals. These signatures arise due to pathological blood flow characteristics and a blood conductivity that strongly depends on the flow field, i.e., the proposed method is, in principle, applicable to any aortic pathology that changes the blood flow characteristics. For the signal classification, we trained a convolutional neural network (CNN) with artificial impedance cardiography data based on a simulation model for a healthy virtual patient and a virtual patient with an aortic dissection. The network architecture was tailored to a multi-sensor, multi-channel time-series classification with a categorical cross-entropy loss function as the training objective. The trained network typically yielded a specificity of [Formula: see text] and a sensitivity of [Formula: see text]. A study of the accuracy as a function of the size of an aortic dissection yielded better results for a small false lumen with larger noise, which emphasizes the question of the feasibility of detecting aortic dissections in an early state.
format Online
Article
Text
id pubmed-8700029
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87000292021-12-24 Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals Spindelböck, Tobias Ranftl, Sascha von der Linden, Wolfgang Entropy (Basel) Article An aortic dissection, a particular aortic pathology, occurs when blood pushes through a tear between the layers of the aorta and forms a so-called false lumen. Aortic dissection has a low incidence compared to other diseases, but a relatively high mortality that increases with disease progression. An early identification and treatment increases patients’ chances of survival. State-of-the-art medical imaging techniques have several disadvantages; therefore, we propose the detection of aortic dissections through their signatures in impedance cardiography signals. These signatures arise due to pathological blood flow characteristics and a blood conductivity that strongly depends on the flow field, i.e., the proposed method is, in principle, applicable to any aortic pathology that changes the blood flow characteristics. For the signal classification, we trained a convolutional neural network (CNN) with artificial impedance cardiography data based on a simulation model for a healthy virtual patient and a virtual patient with an aortic dissection. The network architecture was tailored to a multi-sensor, multi-channel time-series classification with a categorical cross-entropy loss function as the training objective. The trained network typically yielded a specificity of [Formula: see text] and a sensitivity of [Formula: see text]. A study of the accuracy as a function of the size of an aortic dissection yielded better results for a small false lumen with larger noise, which emphasizes the question of the feasibility of detecting aortic dissections in an early state. MDPI 2021-12-10 /pmc/articles/PMC8700029/ /pubmed/34945967 http://dx.doi.org/10.3390/e23121661 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Spindelböck, Tobias
Ranftl, Sascha
von der Linden, Wolfgang
Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title_full Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title_fullStr Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title_full_unstemmed Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title_short Cross-Entropy Learning for Aortic Pathology Classification of Artificial Multi-Sensor Impedance Cardiography Signals
title_sort cross-entropy learning for aortic pathology classification of artificial multi-sensor impedance cardiography signals
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700029/
https://www.ncbi.nlm.nih.gov/pubmed/34945967
http://dx.doi.org/10.3390/e23121661
work_keys_str_mv AT spindelbocktobias crossentropylearningforaorticpathologyclassificationofartificialmultisensorimpedancecardiographysignals
AT ranftlsascha crossentropylearningforaorticpathologyclassificationofartificialmultisensorimpedancecardiographysignals
AT vonderlindenwolfgang crossentropylearningforaorticpathologyclassificationofartificialmultisensorimpedancecardiographysignals