The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review

(1) Background: Computed tomography pulmonary angiography (CTPA) is the standard imaging test for the evaluation of acute pulmonary embolism (PE), but it is associated with patients’ exposure to radiation. Studies have suggested that radiation exposure can be reduced without compromising PE detectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Zaw, Amayar, Nguyen, Rebecca, Lam, Leon, Kaplan, Anthony, Dobler, Claudia C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700432/
https://www.ncbi.nlm.nih.gov/pubmed/34943416
http://dx.doi.org/10.3390/diagnostics11122179
_version_ 1784620755602898944
author Zaw, Amayar
Nguyen, Rebecca
Lam, Leon
Kaplan, Anthony
Dobler, Claudia C.
author_facet Zaw, Amayar
Nguyen, Rebecca
Lam, Leon
Kaplan, Anthony
Dobler, Claudia C.
author_sort Zaw, Amayar
collection PubMed
description (1) Background: Computed tomography pulmonary angiography (CTPA) is the standard imaging test for the evaluation of acute pulmonary embolism (PE), but it is associated with patients’ exposure to radiation. Studies have suggested that radiation exposure can be reduced without compromising PE detection by limiting the scan range (the z-axis, going from up to down); (2) Methods: A literature search was conducted in MEDLINE and EMBASE on 17 July 2021. Studies were included if they enrolled patients who had undergone a CTPA and described the yield of PE diagnoses, number of missed filling defects and/or other diagnoses using a reduced z-axis in comparison to a full-length scan. To assess risk of bias, we modified an existing risk of bias tools for observational studies, the Newcastle-Ottawa Scale. Results were synthesized in a narrative review. Primary outcomes were the number of missed PE diagnoses (based on at least one filling defect) and filling defects; the secondary outcome was the number of other missed findings; (3) Results: Eleven cohort studies and one case-control study were included reporting on a total of 3955 scans including 1025 scans with a diagnosis of PE. Six different reduced scan ranges were assessed; the most studied was from the top of the aortic arch to below the heart, in which no PEs were missed (seven studies). One sub-segmental PE was missed when the scan coverage was 10 cm starting from the bottom of the aortic arch and 14.7 cm starting from the top of the arch. Five studies that reported on other findings all found that other diagnoses were missed with a reduced z-axis. Most of the included studies had a high risk of bias; (4) Conclusions: CTPA scan coverage reduction from the top of aortic arch to below the heart reduced radiation exposure without affecting PE diagnoses, but studies were generally at high risk of bias.
format Online
Article
Text
id pubmed-8700432
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87004322021-12-24 The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review Zaw, Amayar Nguyen, Rebecca Lam, Leon Kaplan, Anthony Dobler, Claudia C. Diagnostics (Basel) Systematic Review (1) Background: Computed tomography pulmonary angiography (CTPA) is the standard imaging test for the evaluation of acute pulmonary embolism (PE), but it is associated with patients’ exposure to radiation. Studies have suggested that radiation exposure can be reduced without compromising PE detection by limiting the scan range (the z-axis, going from up to down); (2) Methods: A literature search was conducted in MEDLINE and EMBASE on 17 July 2021. Studies were included if they enrolled patients who had undergone a CTPA and described the yield of PE diagnoses, number of missed filling defects and/or other diagnoses using a reduced z-axis in comparison to a full-length scan. To assess risk of bias, we modified an existing risk of bias tools for observational studies, the Newcastle-Ottawa Scale. Results were synthesized in a narrative review. Primary outcomes were the number of missed PE diagnoses (based on at least one filling defect) and filling defects; the secondary outcome was the number of other missed findings; (3) Results: Eleven cohort studies and one case-control study were included reporting on a total of 3955 scans including 1025 scans with a diagnosis of PE. Six different reduced scan ranges were assessed; the most studied was from the top of the aortic arch to below the heart, in which no PEs were missed (seven studies). One sub-segmental PE was missed when the scan coverage was 10 cm starting from the bottom of the aortic arch and 14.7 cm starting from the top of the arch. Five studies that reported on other findings all found that other diagnoses were missed with a reduced z-axis. Most of the included studies had a high risk of bias; (4) Conclusions: CTPA scan coverage reduction from the top of aortic arch to below the heart reduced radiation exposure without affecting PE diagnoses, but studies were generally at high risk of bias. MDPI 2021-11-24 /pmc/articles/PMC8700432/ /pubmed/34943416 http://dx.doi.org/10.3390/diagnostics11122179 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Zaw, Amayar
Nguyen, Rebecca
Lam, Leon
Kaplan, Anthony
Dobler, Claudia C.
The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title_full The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title_fullStr The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title_full_unstemmed The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title_short The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review
title_sort effect of limiting the scan range of computed tomography pulmonary angiography (to reduce radiation exposure) on the detection of pulmonary embolism: a systematic review
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700432/
https://www.ncbi.nlm.nih.gov/pubmed/34943416
http://dx.doi.org/10.3390/diagnostics11122179
work_keys_str_mv AT zawamayar theeffectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT nguyenrebecca theeffectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT lamleon theeffectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT kaplananthony theeffectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT doblerclaudiac theeffectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT zawamayar effectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT nguyenrebecca effectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT lamleon effectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT kaplananthony effectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview
AT doblerclaudiac effectoflimitingthescanrangeofcomputedtomographypulmonaryangiographytoreduceradiationexposureonthedetectionofpulmonaryembolismasystematicreview