Cargando…

High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions

To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conv...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Shuyi, Guo, Yihao, Zhang, Xiaoyong, Tao, Juan, Liu, Jie, Zhu, Wenying, Chen, Leqing, Yang, Fan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700489/
https://www.ncbi.nlm.nih.gov/pubmed/34943509
http://dx.doi.org/10.3390/diagnostics11122273
_version_ 1784620769213415424
author Peng, Shuyi
Guo, Yihao
Zhang, Xiaoyong
Tao, Juan
Liu, Jie
Zhu, Wenying
Chen, Leqing
Yang, Fan
author_facet Peng, Shuyi
Guo, Yihao
Zhang, Xiaoyong
Tao, Juan
Liu, Jie
Zhu, Wenying
Chen, Leqing
Yang, Fan
author_sort Peng, Shuyi
collection PubMed
description To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10(−3) vs. 1.43 × 10(−3) mm(2)/s, p = 0.702; malignant 0.91 × 10(−3) vs. 0.89 × 10(−3) mm(2)/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast.
format Online
Article
Text
id pubmed-8700489
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87004892021-12-24 High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions Peng, Shuyi Guo, Yihao Zhang, Xiaoyong Tao, Juan Liu, Jie Zhu, Wenying Chen, Leqing Yang, Fan Diagnostics (Basel) Article To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10(−3) vs. 1.43 × 10(−3) mm(2)/s, p = 0.702; malignant 0.91 × 10(−3) vs. 0.89 × 10(−3) mm(2)/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast. MDPI 2021-12-04 /pmc/articles/PMC8700489/ /pubmed/34943509 http://dx.doi.org/10.3390/diagnostics11122273 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Peng, Shuyi
Guo, Yihao
Zhang, Xiaoyong
Tao, Juan
Liu, Jie
Zhu, Wenying
Chen, Leqing
Yang, Fan
High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title_full High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title_fullStr High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title_full_unstemmed High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title_short High-Resolution DWI with Simultaneous Multi-Slice Readout-Segmented Echo Planar Imaging for the Evaluation of Malignant and Benign Breast Lesions
title_sort high-resolution dwi with simultaneous multi-slice readout-segmented echo planar imaging for the evaluation of malignant and benign breast lesions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8700489/
https://www.ncbi.nlm.nih.gov/pubmed/34943509
http://dx.doi.org/10.3390/diagnostics11122273
work_keys_str_mv AT pengshuyi highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT guoyihao highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT zhangxiaoyong highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT taojuan highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT liujie highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT zhuwenying highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT chenleqing highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions
AT yangfan highresolutiondwiwithsimultaneousmultislicereadoutsegmentedechoplanarimagingfortheevaluationofmalignantandbenignbreastlesions