Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort
Exoskeletons and exosuits (exos) are wearable devices that physically assist movement. User comfort is critically important for societal adoption of exos. Thermal comfort (a person’s satisfaction with their thermal environment) represents a key design challenge. Exos must physically attach/interface...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701000/ https://www.ncbi.nlm.nih.gov/pubmed/34948723 http://dx.doi.org/10.3390/ijerph182413115 |
_version_ | 1784620893699309568 |
---|---|
author | Elstub, Laura J. Fine, Shimra J. Zelik, Karl E. |
author_facet | Elstub, Laura J. Fine, Shimra J. Zelik, Karl E. |
author_sort | Elstub, Laura J. |
collection | PubMed |
description | Exoskeletons and exosuits (exos) are wearable devices that physically assist movement. User comfort is critically important for societal adoption of exos. Thermal comfort (a person’s satisfaction with their thermal environment) represents a key design challenge. Exos must physically attach/interface to the body to apply forces, and these interfaces inevitably trap some heat. It is envisioned that thermal comfort could be improved by designing mode-switching exo interfaces that temporarily loosen around a body segment when assistive forces are not being applied. To inform exo design, a case series study (N = 4) based on single-subject design principles was performed. Our objective was to assess individual responses to skin temperature and thermal comfort during physical activity with a Loose leg-sleeve interface compared with a Form-Fitting one, and immediately after a Form-Fitting sleeve switched to Loose. Skin under the Loose sleeve was 2–3 °C (4–6 °F) cooler after 25 min of physical activity, and two of four participants reported the Loose sleeve improved their thermal comfort. After completion of the physical activity, the Form-Fitting sleeve was loosened, causing a 2–4 °C (3–8 °F) drop in skin temperature underneath for all participants, and two participants to report slightly improved thermal comfort. These findings confirmed that an exo that can quickly loosen its interface when assistance is not required—and re-tighten when it is— has the potential to enhance thermal comfort for some individuals and environments. More broadly, this study demonstrates that mode-switching mechanisms in exos can do more than adjust physical assistance: they can also exploit thermodynamics and facilitate thermoregulation in a way that enhances comfort for exo users. |
format | Online Article Text |
id | pubmed-8701000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87010002021-12-24 Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort Elstub, Laura J. Fine, Shimra J. Zelik, Karl E. Int J Environ Res Public Health Technical Note Exoskeletons and exosuits (exos) are wearable devices that physically assist movement. User comfort is critically important for societal adoption of exos. Thermal comfort (a person’s satisfaction with their thermal environment) represents a key design challenge. Exos must physically attach/interface to the body to apply forces, and these interfaces inevitably trap some heat. It is envisioned that thermal comfort could be improved by designing mode-switching exo interfaces that temporarily loosen around a body segment when assistive forces are not being applied. To inform exo design, a case series study (N = 4) based on single-subject design principles was performed. Our objective was to assess individual responses to skin temperature and thermal comfort during physical activity with a Loose leg-sleeve interface compared with a Form-Fitting one, and immediately after a Form-Fitting sleeve switched to Loose. Skin under the Loose sleeve was 2–3 °C (4–6 °F) cooler after 25 min of physical activity, and two of four participants reported the Loose sleeve improved their thermal comfort. After completion of the physical activity, the Form-Fitting sleeve was loosened, causing a 2–4 °C (3–8 °F) drop in skin temperature underneath for all participants, and two participants to report slightly improved thermal comfort. These findings confirmed that an exo that can quickly loosen its interface when assistance is not required—and re-tighten when it is— has the potential to enhance thermal comfort for some individuals and environments. More broadly, this study demonstrates that mode-switching mechanisms in exos can do more than adjust physical assistance: they can also exploit thermodynamics and facilitate thermoregulation in a way that enhances comfort for exo users. MDPI 2021-12-12 /pmc/articles/PMC8701000/ /pubmed/34948723 http://dx.doi.org/10.3390/ijerph182413115 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Elstub, Laura J. Fine, Shimra J. Zelik, Karl E. Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title | Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title_full | Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title_fullStr | Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title_full_unstemmed | Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title_short | Exoskeletons and Exosuits Could Benefit from Mode-Switching Body Interfaces That Loosen/Tighten to Improve Thermal Comfort |
title_sort | exoskeletons and exosuits could benefit from mode-switching body interfaces that loosen/tighten to improve thermal comfort |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701000/ https://www.ncbi.nlm.nih.gov/pubmed/34948723 http://dx.doi.org/10.3390/ijerph182413115 |
work_keys_str_mv | AT elstublauraj exoskeletonsandexosuitscouldbenefitfrommodeswitchingbodyinterfacesthatloosentightentoimprovethermalcomfort AT fineshimraj exoskeletonsandexosuitscouldbenefitfrommodeswitchingbodyinterfacesthatloosentightentoimprovethermalcomfort AT zelikkarle exoskeletonsandexosuitscouldbenefitfrommodeswitchingbodyinterfacesthatloosentightentoimprovethermalcomfort |