Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults

Continuous glucose monitoring devices measure glucose in interstitial fluid. The devices are effective when used by patients with type 1 and 2 diabetes but are increasingly being used by researchers who are interested in the effects of various behaviours of glucose concentrations in healthy particip...

Descripción completa

Detalles Bibliográficos
Autores principales: Kontou, Thomas G., Sargent, Charli, Roach, Gregory D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701485/
https://www.ncbi.nlm.nih.gov/pubmed/34948608
http://dx.doi.org/10.3390/ijerph182412994
_version_ 1784621012652916736
author Kontou, Thomas G.
Sargent, Charli
Roach, Gregory D.
author_facet Kontou, Thomas G.
Sargent, Charli
Roach, Gregory D.
author_sort Kontou, Thomas G.
collection PubMed
description Continuous glucose monitoring devices measure glucose in interstitial fluid. The devices are effective when used by patients with type 1 and 2 diabetes but are increasingly being used by researchers who are interested in the effects of various behaviours of glucose concentrations in healthy participants. Despite their more frequent application in this setting, the devices have not yet been validated for use under such conditions. A total of 124 healthy participants were recruited to a ten-day laboratory study. Each participant underwent four oral glucose tolerance tests, and a total of 3315 out of a possible 4960 paired samples were included in the final analysis. Bland–Altman plots and mean absolute relative differences were used to determine the agreement between the two methods. Bland–Altman analyses revealed that the continuous glucose monitoring devices had proportional bias (R = 0.028, p < 0.001) and a mean bias of −0.048 mmol/L, and device measurements were more variable as glucose concentrations increased. Ninety-nine per cent of paired values were in Zones A and B of the Parkes Error Grid plot, and there was an overall mean absolute relative difference of 16.2% (±15.8%). There was variability in the continuous glucose monitoring devices, and this variability was higher when glucose concentrations were higher. If researchers were to use continuous glucose monitoring devices to measure glucose concentrations during an oral glucose tolerance test in healthy participants, this variability would need to be considered.
format Online
Article
Text
id pubmed-8701485
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87014852021-12-24 Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults Kontou, Thomas G. Sargent, Charli Roach, Gregory D. Int J Environ Res Public Health Article Continuous glucose monitoring devices measure glucose in interstitial fluid. The devices are effective when used by patients with type 1 and 2 diabetes but are increasingly being used by researchers who are interested in the effects of various behaviours of glucose concentrations in healthy participants. Despite their more frequent application in this setting, the devices have not yet been validated for use under such conditions. A total of 124 healthy participants were recruited to a ten-day laboratory study. Each participant underwent four oral glucose tolerance tests, and a total of 3315 out of a possible 4960 paired samples were included in the final analysis. Bland–Altman plots and mean absolute relative differences were used to determine the agreement between the two methods. Bland–Altman analyses revealed that the continuous glucose monitoring devices had proportional bias (R = 0.028, p < 0.001) and a mean bias of −0.048 mmol/L, and device measurements were more variable as glucose concentrations increased. Ninety-nine per cent of paired values were in Zones A and B of the Parkes Error Grid plot, and there was an overall mean absolute relative difference of 16.2% (±15.8%). There was variability in the continuous glucose monitoring devices, and this variability was higher when glucose concentrations were higher. If researchers were to use continuous glucose monitoring devices to measure glucose concentrations during an oral glucose tolerance test in healthy participants, this variability would need to be considered. MDPI 2021-12-09 /pmc/articles/PMC8701485/ /pubmed/34948608 http://dx.doi.org/10.3390/ijerph182412994 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kontou, Thomas G.
Sargent, Charli
Roach, Gregory D.
Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title_full Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title_fullStr Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title_full_unstemmed Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title_short Glucose Concentrations from Continuous Glucose Monitoring Devices Compared to Those from Blood Plasma during an Oral Glucose Tolerance Test in Healthy Young Adults
title_sort glucose concentrations from continuous glucose monitoring devices compared to those from blood plasma during an oral glucose tolerance test in healthy young adults
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701485/
https://www.ncbi.nlm.nih.gov/pubmed/34948608
http://dx.doi.org/10.3390/ijerph182412994
work_keys_str_mv AT kontouthomasg glucoseconcentrationsfromcontinuousglucosemonitoringdevicescomparedtothosefrombloodplasmaduringanoralglucosetolerancetestinhealthyyoungadults
AT sargentcharli glucoseconcentrationsfromcontinuousglucosemonitoringdevicescomparedtothosefrombloodplasmaduringanoralglucosetolerancetestinhealthyyoungadults
AT roachgregoryd glucoseconcentrationsfromcontinuousglucosemonitoringdevicescomparedtothosefrombloodplasmaduringanoralglucosetolerancetestinhealthyyoungadults