Cargando…

COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination

Background. Serologic assays detecting antibodies against the SARS-CoV-2 spike or nucleocapsid proteins have been developed to advance our understanding of the prognosis and clinical course of the COVID-19 disease. We recently developed a red cell agglutination-based assay to detect severe acute res...

Descripción completa

Detalles Bibliográficos
Autores principales: Flegel, Willy A., Srivastava, Kshitij, De Giorgi, Valeria, Holbrook, Michael R, Bovin, Nicolai V, Henry, Stephen M, West, Kamille
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society of Hematology. Published by Elsevier Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701909/
http://dx.doi.org/10.1182/blood-2021-150795
_version_ 1784621117414047744
author Flegel, Willy A.
Srivastava, Kshitij
De Giorgi, Valeria
Holbrook, Michael R
Bovin, Nicolai V
Henry, Stephen M
West, Kamille
author_facet Flegel, Willy A.
Srivastava, Kshitij
De Giorgi, Valeria
Holbrook, Michael R
Bovin, Nicolai V
Henry, Stephen M
West, Kamille
author_sort Flegel, Willy A.
collection PubMed
description Background. Serologic assays detecting antibodies against the SARS-CoV-2 spike or nucleocapsid proteins have been developed to advance our understanding of the prognosis and clinical course of the COVID-19 disease. We recently developed a red cell agglutination-based assay to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. This assay uses peptide fragments of the SARS-CoV-2 spike protein to label red cells (C19-kodecytes). We performed a clinical evaluation of this C19-kodecyte assay in COVID-19 convalescent plasma (CCP) donors previously assessed with 2 commercial immunoassays and a virus neutralizing assay. Methods. Red cells were coated with peptide fragments of the SARS-CoV-2 spike protein. We tested plasma samples from 140 CCP donors. The results were compared with those of a virus neutralizing assay and 2 commercial chemiluminescent antibody tests: anti-SARS-CoV-2 Total (IgG, IgM and IgA) assay and anti-SARS-CoV-2 IgG assay (Ortho). Inter-rater agreement between the different assays was measured using Cohen's kappa. Specificity was tested with 150 plasma samples, collected in 2008, more than a decade before the COVID-19 outbreak and with 125 plasma samples, collected in 2020 from consecutive healthy volunteer donors, who tested negative for the Ortho Total assay. Testing was performed using the column agglutination technique commonly employed for blood typing. Results. The area under the ROC curve (AUC) for the C19-kodecyte assay reached 0.95 (95% CI: 0.93 - 0.97) with sensitivity of 92.8% (95% CI: 86.9% - 96.3%) and specificity of 96.3% (95% CI: 93.2% - 98.1%). In almost all of the 40 CCP donors with longitudinal data, the antibody concentration decreased during the follow-up, which ranged from 7 to 44 weeks. In the 140 CCP donors, we compared the C19-kodecyte score to the antibody concentrations from the 2 FDA authorized assays (Ortho Total and Ortho IgG) and the titer in the neutralizing assay. There was a positive relationship between the results of all 4 assays. The Spearman's correlation of our assay was 0.20 with the neutralizing assay (0.49 with IgG, and 0.41 with Total assays). Conclusions. Sensitivity and specificity of the C19-kodecyte assay were within the minimum performance range required by the FDA for EUA authorization of serology tests. The limited correlation in assay reaction strengths suggested that the assays may be influenced by different antibody specificities. Unlike the other 84 FDA authorized serologic tests for SARS-CoV-2, this C19-kodecyte assay is a simple and rapid test that can be easily established in any blood typing laboratory worldwide using its routine setup for column agglutination or tube technique. The technique could vastly improve assay capacity, particularly in resource limited hospital blood banks. DISCLOSURES: Bovin:  Kode Biotech: Current Employment, Current holder of stock options in a privately-held company. Henry:  Kode Biotech: Current Employment, Current holder of stock options in a privately-held company.
format Online
Article
Text
id pubmed-8701909
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Society of Hematology. Published by Elsevier Inc.
record_format MEDLINE/PubMed
spelling pubmed-87019092021-12-28 COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination Flegel, Willy A. Srivastava, Kshitij De Giorgi, Valeria Holbrook, Michael R Bovin, Nicolai V Henry, Stephen M West, Kamille Blood 803.Emerging Diagnostic Tools and Techniques Background. Serologic assays detecting antibodies against the SARS-CoV-2 spike or nucleocapsid proteins have been developed to advance our understanding of the prognosis and clinical course of the COVID-19 disease. We recently developed a red cell agglutination-based assay to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. This assay uses peptide fragments of the SARS-CoV-2 spike protein to label red cells (C19-kodecytes). We performed a clinical evaluation of this C19-kodecyte assay in COVID-19 convalescent plasma (CCP) donors previously assessed with 2 commercial immunoassays and a virus neutralizing assay. Methods. Red cells were coated with peptide fragments of the SARS-CoV-2 spike protein. We tested plasma samples from 140 CCP donors. The results were compared with those of a virus neutralizing assay and 2 commercial chemiluminescent antibody tests: anti-SARS-CoV-2 Total (IgG, IgM and IgA) assay and anti-SARS-CoV-2 IgG assay (Ortho). Inter-rater agreement between the different assays was measured using Cohen's kappa. Specificity was tested with 150 plasma samples, collected in 2008, more than a decade before the COVID-19 outbreak and with 125 plasma samples, collected in 2020 from consecutive healthy volunteer donors, who tested negative for the Ortho Total assay. Testing was performed using the column agglutination technique commonly employed for blood typing. Results. The area under the ROC curve (AUC) for the C19-kodecyte assay reached 0.95 (95% CI: 0.93 - 0.97) with sensitivity of 92.8% (95% CI: 86.9% - 96.3%) and specificity of 96.3% (95% CI: 93.2% - 98.1%). In almost all of the 40 CCP donors with longitudinal data, the antibody concentration decreased during the follow-up, which ranged from 7 to 44 weeks. In the 140 CCP donors, we compared the C19-kodecyte score to the antibody concentrations from the 2 FDA authorized assays (Ortho Total and Ortho IgG) and the titer in the neutralizing assay. There was a positive relationship between the results of all 4 assays. The Spearman's correlation of our assay was 0.20 with the neutralizing assay (0.49 with IgG, and 0.41 with Total assays). Conclusions. Sensitivity and specificity of the C19-kodecyte assay were within the minimum performance range required by the FDA for EUA authorization of serology tests. The limited correlation in assay reaction strengths suggested that the assays may be influenced by different antibody specificities. Unlike the other 84 FDA authorized serologic tests for SARS-CoV-2, this C19-kodecyte assay is a simple and rapid test that can be easily established in any blood typing laboratory worldwide using its routine setup for column agglutination or tube technique. The technique could vastly improve assay capacity, particularly in resource limited hospital blood banks. DISCLOSURES: Bovin:  Kode Biotech: Current Employment, Current holder of stock options in a privately-held company. Henry:  Kode Biotech: Current Employment, Current holder of stock options in a privately-held company. American Society of Hematology. Published by Elsevier Inc. 2021-11-23 2021-12-24 /pmc/articles/PMC8701909/ http://dx.doi.org/10.1182/blood-2021-150795 Text en Copyright © 2021 American Society of Hematology. Published by Elsevier Inc. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle 803.Emerging Diagnostic Tools and Techniques
Flegel, Willy A.
Srivastava, Kshitij
De Giorgi, Valeria
Holbrook, Michael R
Bovin, Nicolai V
Henry, Stephen M
West, Kamille
COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title_full COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title_fullStr COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title_full_unstemmed COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title_short COVID-19 Antibody Detection and Assay Performance Using Red Cell Agglutination
title_sort covid-19 antibody detection and assay performance using red cell agglutination
topic 803.Emerging Diagnostic Tools and Techniques
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8701909/
http://dx.doi.org/10.1182/blood-2021-150795
work_keys_str_mv AT flegelwillya covid19antibodydetectionandassayperformanceusingredcellagglutination
AT srivastavakshitij covid19antibodydetectionandassayperformanceusingredcellagglutination
AT degiorgivaleria covid19antibodydetectionandassayperformanceusingredcellagglutination
AT holbrookmichaelr covid19antibodydetectionandassayperformanceusingredcellagglutination
AT bovinnicolaiv covid19antibodydetectionandassayperformanceusingredcellagglutination
AT henrystephenm covid19antibodydetectionandassayperformanceusingredcellagglutination
AT westkamille covid19antibodydetectionandassayperformanceusingredcellagglutination