Cargando…

Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning

OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intr...

Descripción completa

Detalles Bibliográficos
Autores principales: Rengo, Marco, Boru, Cristian E., Badia, Stefano, Iossa, Angelo, Bellini, Davide, Picchia, Simona, Panvini, Nicola, Carbone, Iacopo, Silecchia, Gianfranco, Laghi, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8702505/
https://www.ncbi.nlm.nih.gov/pubmed/34449001
http://dx.doi.org/10.1007/s11547-021-01413-0
_version_ 1784621254432522240
author Rengo, Marco
Boru, Cristian E.
Badia, Stefano
Iossa, Angelo
Bellini, Davide
Picchia, Simona
Panvini, Nicola
Carbone, Iacopo
Silecchia, Gianfranco
Laghi, Andrea
author_facet Rengo, Marco
Boru, Cristian E.
Badia, Stefano
Iossa, Angelo
Bellini, Davide
Picchia, Simona
Panvini, Nicola
Carbone, Iacopo
Silecchia, Gianfranco
Laghi, Andrea
author_sort Rengo, Marco
collection PubMed
description OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intraoperative HSA measurement was considered the reference standard. METHODS: Fifty-two candidates for laparoscopic hiatal hernia repair were prospectively included in the study. MDCT images were acquired during swallowing of oral iodinated contrast media and during strain. Measurements were performed by nine readers divided into three groups according to their experience. Results were compared with intraoperative measurements by means of Spearman correlation coefficient. Reproducibility was evaluated with intra- and interreader agreement by means of weighted Cohen’s kappa and intraclass correlation coefficient (ICC). RESULTS: Significant differences between MDCT and intraoperative HSA measurements were observed for swallowing imaging for less experienced readers (p = 0.037, 0.025, 0.028 and 0.019). No other statistically significant differences were observed (p > 0.05). The correlation between HSA measured intraoperatively and on MDCT was higher for strain imaging compared to swallowing (r = 0.94—0.92 vs 0.94—0.89). The overall reproducibility of MDCT HSA measurement was excellent (ICC of 0.95; 95% CI 0,8993 to 0,9840) independently of reader’s experience CONCLUSION: HSA can be accurately measured on MDCT images. This method is reproducible and minimally influenced by reader experience. The preoperative measurement of HSA has potential advantages for surgeons in terms of correct approach to hiatal defects in obese patient.
format Online
Article
Text
id pubmed-8702505
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-87025052021-12-27 Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning Rengo, Marco Boru, Cristian E. Badia, Stefano Iossa, Angelo Bellini, Davide Picchia, Simona Panvini, Nicola Carbone, Iacopo Silecchia, Gianfranco Laghi, Andrea Radiol Med Abdominal Radiology OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intraoperative HSA measurement was considered the reference standard. METHODS: Fifty-two candidates for laparoscopic hiatal hernia repair were prospectively included in the study. MDCT images were acquired during swallowing of oral iodinated contrast media and during strain. Measurements were performed by nine readers divided into three groups according to their experience. Results were compared with intraoperative measurements by means of Spearman correlation coefficient. Reproducibility was evaluated with intra- and interreader agreement by means of weighted Cohen’s kappa and intraclass correlation coefficient (ICC). RESULTS: Significant differences between MDCT and intraoperative HSA measurements were observed for swallowing imaging for less experienced readers (p = 0.037, 0.025, 0.028 and 0.019). No other statistically significant differences were observed (p > 0.05). The correlation between HSA measured intraoperatively and on MDCT was higher for strain imaging compared to swallowing (r = 0.94—0.92 vs 0.94—0.89). The overall reproducibility of MDCT HSA measurement was excellent (ICC of 0.95; 95% CI 0,8993 to 0,9840) independently of reader’s experience CONCLUSION: HSA can be accurately measured on MDCT images. This method is reproducible and minimally influenced by reader experience. The preoperative measurement of HSA has potential advantages for surgeons in terms of correct approach to hiatal defects in obese patient. Springer Milan 2021-08-27 2021 /pmc/articles/PMC8702505/ /pubmed/34449001 http://dx.doi.org/10.1007/s11547-021-01413-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Abdominal Radiology
Rengo, Marco
Boru, Cristian E.
Badia, Stefano
Iossa, Angelo
Bellini, Davide
Picchia, Simona
Panvini, Nicola
Carbone, Iacopo
Silecchia, Gianfranco
Laghi, Andrea
Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title_full Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title_fullStr Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title_full_unstemmed Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title_short Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
title_sort preoperative measurement of the hiatal surface with mdct: impact on surgical planning
topic Abdominal Radiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8702505/
https://www.ncbi.nlm.nih.gov/pubmed/34449001
http://dx.doi.org/10.1007/s11547-021-01413-0
work_keys_str_mv AT rengomarco preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT borucristiane preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT badiastefano preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT iossaangelo preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT bellinidavide preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT picchiasimona preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT panvininicola preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT carboneiacopo preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT silecchiagianfranco preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning
AT laghiandrea preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning