Cargando…
Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning
OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intr...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Milan
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8702505/ https://www.ncbi.nlm.nih.gov/pubmed/34449001 http://dx.doi.org/10.1007/s11547-021-01413-0 |
_version_ | 1784621254432522240 |
---|---|
author | Rengo, Marco Boru, Cristian E. Badia, Stefano Iossa, Angelo Bellini, Davide Picchia, Simona Panvini, Nicola Carbone, Iacopo Silecchia, Gianfranco Laghi, Andrea |
author_facet | Rengo, Marco Boru, Cristian E. Badia, Stefano Iossa, Angelo Bellini, Davide Picchia, Simona Panvini, Nicola Carbone, Iacopo Silecchia, Gianfranco Laghi, Andrea |
author_sort | Rengo, Marco |
collection | PubMed |
description | OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intraoperative HSA measurement was considered the reference standard. METHODS: Fifty-two candidates for laparoscopic hiatal hernia repair were prospectively included in the study. MDCT images were acquired during swallowing of oral iodinated contrast media and during strain. Measurements were performed by nine readers divided into three groups according to their experience. Results were compared with intraoperative measurements by means of Spearman correlation coefficient. Reproducibility was evaluated with intra- and interreader agreement by means of weighted Cohen’s kappa and intraclass correlation coefficient (ICC). RESULTS: Significant differences between MDCT and intraoperative HSA measurements were observed for swallowing imaging for less experienced readers (p = 0.037, 0.025, 0.028 and 0.019). No other statistically significant differences were observed (p > 0.05). The correlation between HSA measured intraoperatively and on MDCT was higher for strain imaging compared to swallowing (r = 0.94—0.92 vs 0.94—0.89). The overall reproducibility of MDCT HSA measurement was excellent (ICC of 0.95; 95% CI 0,8993 to 0,9840) independently of reader’s experience CONCLUSION: HSA can be accurately measured on MDCT images. This method is reproducible and minimally influenced by reader experience. The preoperative measurement of HSA has potential advantages for surgeons in terms of correct approach to hiatal defects in obese patient. |
format | Online Article Text |
id | pubmed-8702505 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Milan |
record_format | MEDLINE/PubMed |
spelling | pubmed-87025052021-12-27 Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning Rengo, Marco Boru, Cristian E. Badia, Stefano Iossa, Angelo Bellini, Davide Picchia, Simona Panvini, Nicola Carbone, Iacopo Silecchia, Gianfranco Laghi, Andrea Radiol Med Abdominal Radiology OBJECTIVE: To evaluate the accuracy and reproducibility of hiatal surface area (HSA) measurement on dedicated multidetector computed tomography (MDCT) acquisition, in patients, previously subjected to laparoscopic sleeve gastrectomy (LSG), and affected by gastroesophageal reflux disease (GERD). Intraoperative HSA measurement was considered the reference standard. METHODS: Fifty-two candidates for laparoscopic hiatal hernia repair were prospectively included in the study. MDCT images were acquired during swallowing of oral iodinated contrast media and during strain. Measurements were performed by nine readers divided into three groups according to their experience. Results were compared with intraoperative measurements by means of Spearman correlation coefficient. Reproducibility was evaluated with intra- and interreader agreement by means of weighted Cohen’s kappa and intraclass correlation coefficient (ICC). RESULTS: Significant differences between MDCT and intraoperative HSA measurements were observed for swallowing imaging for less experienced readers (p = 0.037, 0.025, 0.028 and 0.019). No other statistically significant differences were observed (p > 0.05). The correlation between HSA measured intraoperatively and on MDCT was higher for strain imaging compared to swallowing (r = 0.94—0.92 vs 0.94—0.89). The overall reproducibility of MDCT HSA measurement was excellent (ICC of 0.95; 95% CI 0,8993 to 0,9840) independently of reader’s experience CONCLUSION: HSA can be accurately measured on MDCT images. This method is reproducible and minimally influenced by reader experience. The preoperative measurement of HSA has potential advantages for surgeons in terms of correct approach to hiatal defects in obese patient. Springer Milan 2021-08-27 2021 /pmc/articles/PMC8702505/ /pubmed/34449001 http://dx.doi.org/10.1007/s11547-021-01413-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Abdominal Radiology Rengo, Marco Boru, Cristian E. Badia, Stefano Iossa, Angelo Bellini, Davide Picchia, Simona Panvini, Nicola Carbone, Iacopo Silecchia, Gianfranco Laghi, Andrea Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title | Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title_full | Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title_fullStr | Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title_full_unstemmed | Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title_short | Preoperative measurement of the hiatal surface with MDCT: impact on surgical planning |
title_sort | preoperative measurement of the hiatal surface with mdct: impact on surgical planning |
topic | Abdominal Radiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8702505/ https://www.ncbi.nlm.nih.gov/pubmed/34449001 http://dx.doi.org/10.1007/s11547-021-01413-0 |
work_keys_str_mv | AT rengomarco preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT borucristiane preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT badiastefano preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT iossaangelo preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT bellinidavide preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT picchiasimona preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT panvininicola preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT carboneiacopo preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT silecchiagianfranco preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning AT laghiandrea preoperativemeasurementofthehiatalsurfacewithmdctimpactonsurgicalplanning |