Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography
Chromatography is a widely used separation process for purification of biopharmaceuticals that is able to obtain high purities and concentrations. The phenomena that occur during separation, mass transfer and adsorption are quite complex. To better understand these phenomena and their mechanisms, mu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8703794/ https://www.ncbi.nlm.nih.gov/pubmed/34959416 http://dx.doi.org/10.3390/pharmaceutics13122135 |
_version_ | 1784621550300823552 |
---|---|
author | Lietta, Elena Pieri, Alessandro Innocenti, Elisa Pisano, Roberto Vanni, Marco Barresi, Antonello A. |
author_facet | Lietta, Elena Pieri, Alessandro Innocenti, Elisa Pisano, Roberto Vanni, Marco Barresi, Antonello A. |
author_sort | Lietta, Elena |
collection | PubMed |
description | Chromatography is a widely used separation process for purification of biopharmaceuticals that is able to obtain high purities and concentrations. The phenomena that occur during separation, mass transfer and adsorption are quite complex. To better understand these phenomena and their mechanisms, multi-component adsorption isotherms must be investigated. High-throughput methodologies are a very powerful tool to determine adsorption isotherms and they waste very small amounts of sample and chemicals, but the quantification of component concentrations is a real bottleneck in multi-component isotherm determination. The behavior of bovine serum albumin, Corynebacterium diphtheriae CRM(197) protein and lysozyme, selected as model proteins in binary mixtures with hydrophobic resin, is investigated here. In this work we propose a new method for determining multi-component adsorption isotherms using high-throughput experiments with filter plates, by exploiting microfluidic capillary electrophoresis. The precision and accuracy of the microfluidic capillary electrophoresis platform were evaluated in order to assess the procedure; they were both found to be high and the procedure is thus reliable in determining adsorption isotherms for binary mixtures. Multi-component adsorption isotherms were determined with a totally high-throughput procedure that turned out to be a very fast and powerful tool. The same procedure can be applied to every kind of high-throughput screening. |
format | Online Article Text |
id | pubmed-8703794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87037942021-12-25 Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography Lietta, Elena Pieri, Alessandro Innocenti, Elisa Pisano, Roberto Vanni, Marco Barresi, Antonello A. Pharmaceutics Article Chromatography is a widely used separation process for purification of biopharmaceuticals that is able to obtain high purities and concentrations. The phenomena that occur during separation, mass transfer and adsorption are quite complex. To better understand these phenomena and their mechanisms, multi-component adsorption isotherms must be investigated. High-throughput methodologies are a very powerful tool to determine adsorption isotherms and they waste very small amounts of sample and chemicals, but the quantification of component concentrations is a real bottleneck in multi-component isotherm determination. The behavior of bovine serum albumin, Corynebacterium diphtheriae CRM(197) protein and lysozyme, selected as model proteins in binary mixtures with hydrophobic resin, is investigated here. In this work we propose a new method for determining multi-component adsorption isotherms using high-throughput experiments with filter plates, by exploiting microfluidic capillary electrophoresis. The precision and accuracy of the microfluidic capillary electrophoresis platform were evaluated in order to assess the procedure; they were both found to be high and the procedure is thus reliable in determining adsorption isotherms for binary mixtures. Multi-component adsorption isotherms were determined with a totally high-throughput procedure that turned out to be a very fast and powerful tool. The same procedure can be applied to every kind of high-throughput screening. MDPI 2021-12-11 /pmc/articles/PMC8703794/ /pubmed/34959416 http://dx.doi.org/10.3390/pharmaceutics13122135 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lietta, Elena Pieri, Alessandro Innocenti, Elisa Pisano, Roberto Vanni, Marco Barresi, Antonello A. Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title | Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title_full | Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title_fullStr | Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title_full_unstemmed | Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title_short | Use of Microfluidic Capillary Electrophoresis for the Determination of Multi-Component Protein Adsorption Isotherms: Application to High-Throughput Analysis for Hydrophobic Interaction Chromatography |
title_sort | use of microfluidic capillary electrophoresis for the determination of multi-component protein adsorption isotherms: application to high-throughput analysis for hydrophobic interaction chromatography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8703794/ https://www.ncbi.nlm.nih.gov/pubmed/34959416 http://dx.doi.org/10.3390/pharmaceutics13122135 |
work_keys_str_mv | AT liettaelena useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography AT pierialessandro useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography AT innocentielisa useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography AT pisanoroberto useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography AT vannimarco useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography AT barresiantonelloa useofmicrofluidiccapillaryelectrophoresisforthedeterminationofmulticomponentproteinadsorptionisothermsapplicationtohighthroughputanalysisforhydrophobicinteractionchromatography |