Cargando…
Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique
Background and Objectives: Currently, one of the most discouraging aspects for many patients undergoing dental procedures is the administration of anaesthesia. Consequently, there is a constant search for new techniques to avoid the invasive and painful nature of the injection. A new motorised syrin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8704324/ https://www.ncbi.nlm.nih.gov/pubmed/34946280 http://dx.doi.org/10.3390/medicina57121335 |
_version_ | 1784621680191078400 |
---|---|
author | Fernández-Castellano, Erick Rafael Blanco-Antona, Leticia Alejandra Vicente-Galindo, Purificación Amor-Esteban, Víctor Flores-Fraile, Javier |
author_facet | Fernández-Castellano, Erick Rafael Blanco-Antona, Leticia Alejandra Vicente-Galindo, Purificación Amor-Esteban, Víctor Flores-Fraile, Javier |
author_sort | Fernández-Castellano, Erick Rafael |
collection | PubMed |
description | Background and Objectives: Currently, one of the most discouraging aspects for many patients undergoing dental procedures is the administration of anaesthesia. Consequently, there is a constant search for new techniques to avoid the invasive and painful nature of the injection. A new motorised syringe system (Dentapen(®)) has recently been developed, standing out for its convenience and ease of use. Material and Methods: Randomised, controlled, single-blind, and single-centre study including 178 voluntary adult participants aged between 18 and 90 years. Individuals were randomly assigned using a randomised table. Patients were asked to rate the level of pain experienced during the injections, using a 10-point visual analogue scale (VAS). The following data were recorded: pain index, heart rate, blood pressure, and saturation, both before and after anaesthesia. Results: Of the total 178 participants, 87 participants (48.9%) were men and 91 (51.1%) were women. The first variable to be assessed was the pain experienced by patients when anaesthetised with a syringe, obtaining a mean value of 2.63 ± 1.86 on the VAS with the conventional syringe and 1.06 ± 1.28 with the Dentapen(®) syringe, showing statistically significant differences (p-value < 0.01). When stratifying, based on the procedure that was undertaken, differences were also significant for all treatments (p-value < 0.01) except for endodontics, where differences were likely to be significant (p-value = 0.02). Conclusions: In conclusion, from a clinical standpoint, the Dentapen(®) syringe is a valid alternative to traditional infiltration syringes, causing minimum pain with the injection. |
format | Online Article Text |
id | pubmed-8704324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87043242021-12-25 Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique Fernández-Castellano, Erick Rafael Blanco-Antona, Leticia Alejandra Vicente-Galindo, Purificación Amor-Esteban, Víctor Flores-Fraile, Javier Medicina (Kaunas) Article Background and Objectives: Currently, one of the most discouraging aspects for many patients undergoing dental procedures is the administration of anaesthesia. Consequently, there is a constant search for new techniques to avoid the invasive and painful nature of the injection. A new motorised syringe system (Dentapen(®)) has recently been developed, standing out for its convenience and ease of use. Material and Methods: Randomised, controlled, single-blind, and single-centre study including 178 voluntary adult participants aged between 18 and 90 years. Individuals were randomly assigned using a randomised table. Patients were asked to rate the level of pain experienced during the injections, using a 10-point visual analogue scale (VAS). The following data were recorded: pain index, heart rate, blood pressure, and saturation, both before and after anaesthesia. Results: Of the total 178 participants, 87 participants (48.9%) were men and 91 (51.1%) were women. The first variable to be assessed was the pain experienced by patients when anaesthetised with a syringe, obtaining a mean value of 2.63 ± 1.86 on the VAS with the conventional syringe and 1.06 ± 1.28 with the Dentapen(®) syringe, showing statistically significant differences (p-value < 0.01). When stratifying, based on the procedure that was undertaken, differences were also significant for all treatments (p-value < 0.01) except for endodontics, where differences were likely to be significant (p-value = 0.02). Conclusions: In conclusion, from a clinical standpoint, the Dentapen(®) syringe is a valid alternative to traditional infiltration syringes, causing minimum pain with the injection. MDPI 2021-12-07 /pmc/articles/PMC8704324/ /pubmed/34946280 http://dx.doi.org/10.3390/medicina57121335 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fernández-Castellano, Erick Rafael Blanco-Antona, Leticia Alejandra Vicente-Galindo, Purificación Amor-Esteban, Víctor Flores-Fraile, Javier Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title | Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title_full | Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title_fullStr | Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title_full_unstemmed | Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title_short | Pain Experienced during Various Dental Procedures: Clinical Trial Comparing the Use of Traditional Syringes with the Controlled-Flow Delivery Dentapen(®) Technique |
title_sort | pain experienced during various dental procedures: clinical trial comparing the use of traditional syringes with the controlled-flow delivery dentapen(®) technique |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8704324/ https://www.ncbi.nlm.nih.gov/pubmed/34946280 http://dx.doi.org/10.3390/medicina57121335 |
work_keys_str_mv | AT fernandezcastellanoerickrafael painexperiencedduringvariousdentalproceduresclinicaltrialcomparingtheuseoftraditionalsyringeswiththecontrolledflowdeliverydentapentechnique AT blancoantonaleticiaalejandra painexperiencedduringvariousdentalproceduresclinicaltrialcomparingtheuseoftraditionalsyringeswiththecontrolledflowdeliverydentapentechnique AT vicentegalindopurificacion painexperiencedduringvariousdentalproceduresclinicaltrialcomparingtheuseoftraditionalsyringeswiththecontrolledflowdeliverydentapentechnique AT amorestebanvictor painexperiencedduringvariousdentalproceduresclinicaltrialcomparingtheuseoftraditionalsyringeswiththecontrolledflowdeliverydentapentechnique AT floresfrailejavier painexperiencedduringvariousdentalproceduresclinicaltrialcomparingtheuseoftraditionalsyringeswiththecontrolledflowdeliverydentapentechnique |