Cargando…

Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability

CATEGORY: Ankle; Ankle Arthritis; Arthroscopy; Sports INTRODUCTION/PURPOSE: Chronic subtle distal tibiofibular syndesmotic instability (DTFSI) is relatively common, and consequences of undiagnosed injuries can be devastating. Diagnosing acute and chronic injuries is challenging, and the most commonl...

Descripción completa

Detalles Bibliográficos
Autores principales: de Cesar Netto, Cesar, Lintz, Francois, Goetz, Jessica E., Dibbern, Kevin N., Giarola, Ivan C., Godoy-Santos, Alexandre L., Guss, Daniel, Femino, John E., Anderson, Donald D., DiGiovanni, Christopher W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8704899/
http://dx.doi.org/10.1177/2473011420S00190
_version_ 1784621816904417280
author de Cesar Netto, Cesar
Lintz, Francois
Goetz, Jessica E.
Dibbern, Kevin N.
Giarola, Ivan C.
Godoy-Santos, Alexandre L.
Guss, Daniel
Femino, John E.
Anderson, Donald D.
DiGiovanni, Christopher W.
author_facet de Cesar Netto, Cesar
Lintz, Francois
Goetz, Jessica E.
Dibbern, Kevin N.
Giarola, Ivan C.
Godoy-Santos, Alexandre L.
Guss, Daniel
Femino, John E.
Anderson, Donald D.
DiGiovanni, Christopher W.
author_sort de Cesar Netto, Cesar
collection PubMed
description CATEGORY: Ankle; Ankle Arthritis; Arthroscopy; Sports INTRODUCTION/PURPOSE: Chronic subtle distal tibiofibular syndesmotic instability (DTFSI) is relatively common, and consequences of undiagnosed injuries can be devastating. Diagnosing acute and chronic injuries is challenging, and the most commonly used diagnostic tools are physical exams, conventional radiographs and bilateral CT, and MRI. Arthroscopic assessment, an invasive method, is currently considered the gold standard. Weightbearing CT has just emerged as an excellent dynamic non-invasive diagnostic test. Recent literature highlighted the accuracy of syndesmotic incisura area measurements in diagnosing subtle DTFSI. The aim of our study was to develop and validate the use of a novel automatic 3D volumetric assessment of the incisura, and to compare the measurements between patients with surgically confirmed DTFSI and controls. METHODS: In this IRB-approved case-control study, patients with suspected unilateral chronic subtle DTFSI underwent bilateral standing weightbearing CT (WBCT) examination before surgical treatment. DTFSI was confirmed by arthroscopic assessment. We also included control patients that underwent WBCT tests for forefoot related problems and no history of syndesmotic injuries. The syndesmotic incisura volume (mm3) was measured starting at the level of the ankle joint to two proximal points, 10 and 15mm proximally to the joint. A 3D automatic measurement algorithm composed of automated segmentation of the distal tibia and fibula and recognition of the incisura volume based on Hounsfield units (HU) assessment was performed. Measurements were compared between DTFSI patients and controls. A partition prediction model, ROC curves and area under the curve (AUC) were performed to assess the diagnostic accuracy of the automatic volumetric analysis to detect DTFSI. P-values of less than 0.05 were considered significant. RESULTS: In this preliminary report, four patients with DTFSI and seven controls were included. Mean value and 95% CI for 3D Syndesmotic Incisura volumetric measurements at 10 and 15mm points: 1457 mm3 (1233 to 1680)/2241 mm3 (1951 to 2531) for controls, and 1679 mm3 (910 to 2447)/2425 mm3 (1408 to 3443) for patients with DTFSI (p-values of respectively 0.35 and 0.55).When comparing injured and uninjured DTFSI ankles, volume measurements at 10 and 15mm points were increased on injured ankles, with a Hodges-Lehmann difference of respectively 287 mm3 (p=0.19), and 186 mm3 (p=0.31). The partition model demonstrated that the volume of the first 10mm was the best predictor of DTFSI, with only 3% chances of DTFSI when the incisura volume was below 1291 mm3 (AUC=0.71). CONCLUSION: Our study aimed to describe and validate the use of a novel automatic 3D volumetric measurement of the distal tibiofibular incisura in patients with chronic subtle ankle syndesmotic instability and controls. Our preliminary results demonstrated increased volumes on injured ankles when compared to contralateral uninjured ankles and controls. Measurements performed within the first 10mm length of the syndesmosis were found to predict better the presence of syndesmotic instability, with a volume of 1291 mm3 representing an important diagnostic threshold. Automatic 3D WBCT volumetric measurements may represent a useful non-invasive diagnostic tool for subtle and chronic syndesmotic instability.
format Online
Article
Text
id pubmed-8704899
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87048992022-01-28 Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability de Cesar Netto, Cesar Lintz, Francois Goetz, Jessica E. Dibbern, Kevin N. Giarola, Ivan C. Godoy-Santos, Alexandre L. Guss, Daniel Femino, John E. Anderson, Donald D. DiGiovanni, Christopher W. Foot Ankle Orthop Article CATEGORY: Ankle; Ankle Arthritis; Arthroscopy; Sports INTRODUCTION/PURPOSE: Chronic subtle distal tibiofibular syndesmotic instability (DTFSI) is relatively common, and consequences of undiagnosed injuries can be devastating. Diagnosing acute and chronic injuries is challenging, and the most commonly used diagnostic tools are physical exams, conventional radiographs and bilateral CT, and MRI. Arthroscopic assessment, an invasive method, is currently considered the gold standard. Weightbearing CT has just emerged as an excellent dynamic non-invasive diagnostic test. Recent literature highlighted the accuracy of syndesmotic incisura area measurements in diagnosing subtle DTFSI. The aim of our study was to develop and validate the use of a novel automatic 3D volumetric assessment of the incisura, and to compare the measurements between patients with surgically confirmed DTFSI and controls. METHODS: In this IRB-approved case-control study, patients with suspected unilateral chronic subtle DTFSI underwent bilateral standing weightbearing CT (WBCT) examination before surgical treatment. DTFSI was confirmed by arthroscopic assessment. We also included control patients that underwent WBCT tests for forefoot related problems and no history of syndesmotic injuries. The syndesmotic incisura volume (mm3) was measured starting at the level of the ankle joint to two proximal points, 10 and 15mm proximally to the joint. A 3D automatic measurement algorithm composed of automated segmentation of the distal tibia and fibula and recognition of the incisura volume based on Hounsfield units (HU) assessment was performed. Measurements were compared between DTFSI patients and controls. A partition prediction model, ROC curves and area under the curve (AUC) were performed to assess the diagnostic accuracy of the automatic volumetric analysis to detect DTFSI. P-values of less than 0.05 were considered significant. RESULTS: In this preliminary report, four patients with DTFSI and seven controls were included. Mean value and 95% CI for 3D Syndesmotic Incisura volumetric measurements at 10 and 15mm points: 1457 mm3 (1233 to 1680)/2241 mm3 (1951 to 2531) for controls, and 1679 mm3 (910 to 2447)/2425 mm3 (1408 to 3443) for patients with DTFSI (p-values of respectively 0.35 and 0.55).When comparing injured and uninjured DTFSI ankles, volume measurements at 10 and 15mm points were increased on injured ankles, with a Hodges-Lehmann difference of respectively 287 mm3 (p=0.19), and 186 mm3 (p=0.31). The partition model demonstrated that the volume of the first 10mm was the best predictor of DTFSI, with only 3% chances of DTFSI when the incisura volume was below 1291 mm3 (AUC=0.71). CONCLUSION: Our study aimed to describe and validate the use of a novel automatic 3D volumetric measurement of the distal tibiofibular incisura in patients with chronic subtle ankle syndesmotic instability and controls. Our preliminary results demonstrated increased volumes on injured ankles when compared to contralateral uninjured ankles and controls. Measurements performed within the first 10mm length of the syndesmosis were found to predict better the presence of syndesmotic instability, with a volume of 1291 mm3 representing an important diagnostic threshold. Automatic 3D WBCT volumetric measurements may represent a useful non-invasive diagnostic tool for subtle and chronic syndesmotic instability. SAGE Publications 2020-11-06 /pmc/articles/PMC8704899/ http://dx.doi.org/10.1177/2473011420S00190 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
de Cesar Netto, Cesar
Lintz, Francois
Goetz, Jessica E.
Dibbern, Kevin N.
Giarola, Ivan C.
Godoy-Santos, Alexandre L.
Guss, Daniel
Femino, John E.
Anderson, Donald D.
DiGiovanni, Christopher W.
Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title_full Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title_fullStr Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title_full_unstemmed Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title_short Automatic 3D Volumetric Analysys of the Distal Tibiofibular Syndesmotic Incisura: A Case-Control Study of Subtle Chronic Syndesmotic Instability
title_sort automatic 3d volumetric analysys of the distal tibiofibular syndesmotic incisura: a case-control study of subtle chronic syndesmotic instability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8704899/
http://dx.doi.org/10.1177/2473011420S00190
work_keys_str_mv AT decesarnettocesar automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT lintzfrancois automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT goetzjessicae automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT dibbernkevinn automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT giarolaivanc automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT godoysantosalexandrel automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT gussdaniel automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT feminojohne automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT andersondonaldd automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability
AT digiovannichristopherw automatic3dvolumetricanalysysofthedistaltibiofibularsyndesmoticincisuraacasecontrolstudyofsubtlechronicsyndesmoticinstability