Cargando…

Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert

CATEGORY: Ankle; Ankle Arthritis INTRODUCTION/PURPOSE: The success of total ankle arthroplasty (TAA) depends on many factors, including patient selection, prosthetic design, soft tissue balancing, severity of joint deformity, and component position. Malposition of the components increases contact pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Kayum, Shahin, Khan, Ryan M., Daniels, Timothy R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8705365/
http://dx.doi.org/10.1177/2473011420S00277
_version_ 1784621928196079616
author Kayum, Shahin
Khan, Ryan M.
Daniels, Timothy R.
author_facet Kayum, Shahin
Khan, Ryan M.
Daniels, Timothy R.
author_sort Kayum, Shahin
collection PubMed
description CATEGORY: Ankle; Ankle Arthritis INTRODUCTION/PURPOSE: The success of total ankle arthroplasty (TAA) depends on many factors, including patient selection, prosthetic design, soft tissue balancing, severity of joint deformity, and component position. Malposition of the components increases contact pressures and diminishes prosthesis survival / patient outcomes; therefore, anatomic alignment of the prosthesis is desirable. Sagittal malalignment of the talar component is common and has been associated with lower outcome scores. Cadance Total ankle system is unique in that it has modular polyethene components with both an anterior and posterior biased option that may help improve reduction of the talus in the sagittal plane. The purpose of this study is to evaluate the effectiveness of anterior and posterior biased polyethylethene liners in improving sagittal component alignment in patients with preoperative sagittal translational deformities METHODS: This is a prospective radiographic and clinical study of patients that underwent TAA with the Cadence(TM) system using biased polyethylene liners with at least 12-months follow-up. All surgeries were performed by a single surgeon with extensive experience in TAA between July 2016 and December 2018. Patients underwent TAA in a standard fashion using an anterior approach, and then underwent clinical evaluation at standardized time points with administration of the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-26). Radiographic outcomes included assessment of sagittal plane component alignment using the tibiotalar (TT) ratio and tibial-axis-to-lateral-process distance at preoperative and at postoperative visits. RESULTS: The cohort included a total of 7O TAA which demonstrated pre-operative sagittal talar malalignment and/or intra- operative sagittal instability where a biased polyethylene liner was inserted. Preoperative talar sagittal translation was 54 anterior, 6 posterior and 10 were neutral. 30 anterior biased polyethylene and 40 posterior biased polyethylene were used. Sagittal translation decreased from an average 4.2 mm to 0.8 mm. The T-T ratio averaged 40.8 +- 10.8 % on preoperative x-ray and 38.1 +- 3.6 % on postoperative. The pre and post-operative pain and disability scores displayed statistically significant improvements wherein AOS pain scores decreased 25.28 +- 14.34 points from an average of 45.86 points while AOS disability scores decreased -30.11 +- 22.70 from an average of 56.15 points. CONCLUSION: Sagittal translational deformities associated with end-stage ankle arthritis are common and should be corrected during TAA to improve loading kinematics and implant longevity. The Cadence TAA has anterior and posterior biased polyethylene liners that help to correct sagittal talar translational deformities. This study demonstrates that biased liners are effective in improved postoperative clinical outcomes with significant correction of pathological sagittal translation to near anatomic alignment.
format Online
Article
Text
id pubmed-8705365
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87053652022-01-28 Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert Kayum, Shahin Khan, Ryan M. Daniels, Timothy R. Foot Ankle Orthop Article CATEGORY: Ankle; Ankle Arthritis INTRODUCTION/PURPOSE: The success of total ankle arthroplasty (TAA) depends on many factors, including patient selection, prosthetic design, soft tissue balancing, severity of joint deformity, and component position. Malposition of the components increases contact pressures and diminishes prosthesis survival / patient outcomes; therefore, anatomic alignment of the prosthesis is desirable. Sagittal malalignment of the talar component is common and has been associated with lower outcome scores. Cadance Total ankle system is unique in that it has modular polyethene components with both an anterior and posterior biased option that may help improve reduction of the talus in the sagittal plane. The purpose of this study is to evaluate the effectiveness of anterior and posterior biased polyethylethene liners in improving sagittal component alignment in patients with preoperative sagittal translational deformities METHODS: This is a prospective radiographic and clinical study of patients that underwent TAA with the Cadence(TM) system using biased polyethylene liners with at least 12-months follow-up. All surgeries were performed by a single surgeon with extensive experience in TAA between July 2016 and December 2018. Patients underwent TAA in a standard fashion using an anterior approach, and then underwent clinical evaluation at standardized time points with administration of the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-26). Radiographic outcomes included assessment of sagittal plane component alignment using the tibiotalar (TT) ratio and tibial-axis-to-lateral-process distance at preoperative and at postoperative visits. RESULTS: The cohort included a total of 7O TAA which demonstrated pre-operative sagittal talar malalignment and/or intra- operative sagittal instability where a biased polyethylene liner was inserted. Preoperative talar sagittal translation was 54 anterior, 6 posterior and 10 were neutral. 30 anterior biased polyethylene and 40 posterior biased polyethylene were used. Sagittal translation decreased from an average 4.2 mm to 0.8 mm. The T-T ratio averaged 40.8 +- 10.8 % on preoperative x-ray and 38.1 +- 3.6 % on postoperative. The pre and post-operative pain and disability scores displayed statistically significant improvements wherein AOS pain scores decreased 25.28 +- 14.34 points from an average of 45.86 points while AOS disability scores decreased -30.11 +- 22.70 from an average of 56.15 points. CONCLUSION: Sagittal translational deformities associated with end-stage ankle arthritis are common and should be corrected during TAA to improve loading kinematics and implant longevity. The Cadence TAA has anterior and posterior biased polyethylene liners that help to correct sagittal talar translational deformities. This study demonstrates that biased liners are effective in improved postoperative clinical outcomes with significant correction of pathological sagittal translation to near anatomic alignment. SAGE Publications 2020-11-06 /pmc/articles/PMC8705365/ http://dx.doi.org/10.1177/2473011420S00277 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Kayum, Shahin
Khan, Ryan M.
Daniels, Timothy R.
Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title_full Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title_fullStr Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title_full_unstemmed Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title_short Correction of Talar Sagittal Alignment in Total Ankle Replacement using Cadence Biased Polyethylene Insert
title_sort correction of talar sagittal alignment in total ankle replacement using cadence biased polyethylene insert
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8705365/
http://dx.doi.org/10.1177/2473011420S00277
work_keys_str_mv AT kayumshahin correctionoftalarsagittalalignmentintotalanklereplacementusingcadencebiasedpolyethyleneinsert
AT khanryanm correctionoftalarsagittalalignmentintotalanklereplacementusingcadencebiasedpolyethyleneinsert
AT danielstimothyr correctionoftalarsagittalalignmentintotalanklereplacementusingcadencebiasedpolyethyleneinsert