Cargando…

Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions

Heart rate (HR) and heart rate variability (HRV) based physiological metrics such as Excess Post-exercise Oxygen Consumption (EPOC), Energy Expenditure (EE), and Training Impulse (TRIMP) are widely utilized in coaching to monitor and optimize an athlete’s training load. Chest straps, and recently al...

Descripción completa

Detalles Bibliográficos
Autores principales: Parak, Jakub, Salonen, Mikko, Myllymäki, Tero, Korhonen, Ilkka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8706206/
https://www.ncbi.nlm.nih.gov/pubmed/34960501
http://dx.doi.org/10.3390/s21248411
_version_ 1784622136742117376
author Parak, Jakub
Salonen, Mikko
Myllymäki, Tero
Korhonen, Ilkka
author_facet Parak, Jakub
Salonen, Mikko
Myllymäki, Tero
Korhonen, Ilkka
author_sort Parak, Jakub
collection PubMed
description Heart rate (HR) and heart rate variability (HRV) based physiological metrics such as Excess Post-exercise Oxygen Consumption (EPOC), Energy Expenditure (EE), and Training Impulse (TRIMP) are widely utilized in coaching to monitor and optimize an athlete’s training load. Chest straps, and recently also dry electrodes integrated to special sports vests, are used to monitor HR during sports. Mechanical design, placement of electrodes, and ergonomics of the sensor affect the measured signal quality and artefacts. To evaluate the impact of the sensor mechanical design on the accuracy of the HR/HRV and further on to estimation of EPOC, EE, and TRIMP, we recorded HR and HRV from a chest strap and a vest with the same ECG sensor during supervised exercise protocol. A 3-lead clinical Holter ECG was used as a reference. Twenty-five healthy subjects (six females) participated. Mean absolute percentage error (MAPE) for HR was 0.76% with chest strap and 3.32% with vest. MAPE was 1.70% vs. 6.73% for EE, 0.38% vs. 8.99% for TRIMP and 3.90% vs. 54.15% for EPOC with chest strap and vest, respectively. Results suggest superior accuracy of chest strap over vest for HR and physiological metrics monitoring during sports.
format Online
Article
Text
id pubmed-8706206
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87062062021-12-25 Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions Parak, Jakub Salonen, Mikko Myllymäki, Tero Korhonen, Ilkka Sensors (Basel) Article Heart rate (HR) and heart rate variability (HRV) based physiological metrics such as Excess Post-exercise Oxygen Consumption (EPOC), Energy Expenditure (EE), and Training Impulse (TRIMP) are widely utilized in coaching to monitor and optimize an athlete’s training load. Chest straps, and recently also dry electrodes integrated to special sports vests, are used to monitor HR during sports. Mechanical design, placement of electrodes, and ergonomics of the sensor affect the measured signal quality and artefacts. To evaluate the impact of the sensor mechanical design on the accuracy of the HR/HRV and further on to estimation of EPOC, EE, and TRIMP, we recorded HR and HRV from a chest strap and a vest with the same ECG sensor during supervised exercise protocol. A 3-lead clinical Holter ECG was used as a reference. Twenty-five healthy subjects (six females) participated. Mean absolute percentage error (MAPE) for HR was 0.76% with chest strap and 3.32% with vest. MAPE was 1.70% vs. 6.73% for EE, 0.38% vs. 8.99% for TRIMP and 3.90% vs. 54.15% for EPOC with chest strap and vest, respectively. Results suggest superior accuracy of chest strap over vest for HR and physiological metrics monitoring during sports. MDPI 2021-12-16 /pmc/articles/PMC8706206/ /pubmed/34960501 http://dx.doi.org/10.3390/s21248411 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Parak, Jakub
Salonen, Mikko
Myllymäki, Tero
Korhonen, Ilkka
Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title_full Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title_fullStr Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title_full_unstemmed Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title_short Comparison of Heart Rate Monitoring Accuracy between Chest Strap and Vest during Physical Training and Implications on Training Decisions
title_sort comparison of heart rate monitoring accuracy between chest strap and vest during physical training and implications on training decisions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8706206/
https://www.ncbi.nlm.nih.gov/pubmed/34960501
http://dx.doi.org/10.3390/s21248411
work_keys_str_mv AT parakjakub comparisonofheartratemonitoringaccuracybetweencheststrapandvestduringphysicaltrainingandimplicationsontrainingdecisions
AT salonenmikko comparisonofheartratemonitoringaccuracybetweencheststrapandvestduringphysicaltrainingandimplicationsontrainingdecisions
AT myllymakitero comparisonofheartratemonitoringaccuracybetweencheststrapandvestduringphysicaltrainingandimplicationsontrainingdecisions
AT korhonenilkka comparisonofheartratemonitoringaccuracybetweencheststrapandvestduringphysicaltrainingandimplicationsontrainingdecisions