Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT

Evaluation of Parkinsonian Syndromes (PS) with Ioflupane iodine-123 dopamine transporter single photon emission computed tomography (DaT-SPECT), in conjunction with history and clinical examination, aids in diagnosis. FDA-approved, semi-quantitative software, DaTQUANT(TM) (GE Healthcare, Chicago, IL...

Descripción completa

Detalles Bibliográficos
Autores principales: Neill, Matthew, Fisher, Julia M., Brand, Christine, Lei, Hong, Sherman, Scott J., Chou, Ying-Hui, Kuo, Phillip H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8706562/
https://www.ncbi.nlm.nih.gov/pubmed/34941653
http://dx.doi.org/10.3390/tomography7040081
_version_ 1784622222980153344
author Neill, Matthew
Fisher, Julia M.
Brand, Christine
Lei, Hong
Sherman, Scott J.
Chou, Ying-Hui
Kuo, Phillip H.
author_facet Neill, Matthew
Fisher, Julia M.
Brand, Christine
Lei, Hong
Sherman, Scott J.
Chou, Ying-Hui
Kuo, Phillip H.
author_sort Neill, Matthew
collection PubMed
description Evaluation of Parkinsonian Syndromes (PS) with Ioflupane iodine-123 dopamine transporter single photon emission computed tomography (DaT-SPECT), in conjunction with history and clinical examination, aids in diagnosis. FDA-approved, semi-quantitative software, DaTQUANT(TM) (GE Healthcare, Chicago, IL, USA) is available to assist in interpretation. This study aims to evaluate the optimal variables and thresholds of DaTQUANT to yield the optimal diagnostic accuracy. It is a retrospective review with three different patient populations. DaT-SPECT images from all three study groups were evaluated using DaTQUANT(TM) software, and both single and multi-variable logistic regression were used to model PS status. The optimal models were chosen via accuracy, sensitivity, and specificity, then evaluated on the other study groups. Among single variable models, the posterior putamen yielded the highest accuracy (84% to 95%), while balancing sensitivity and specificity. Multi-variable models did not substantially improve the accuracy. When the optimal single variable models for each group were used to evaluate the remaining two groups, comparable results were achieved. In typical utilization of DaT-SPECT for differentiation between nigrostriatal degenerative disease (NSDD) and non-NSDD, the posterior putamen was the single variable that yielded the highest accuracy across three different patient populations. The posterior putamen’s recommended thresholds for DaTQUANT are SBR ≤ 1.0, z-score of ≤−1.8 and percent deviation ≤ −0.34.
format Online
Article
Text
id pubmed-8706562
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87065622021-12-25 Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT Neill, Matthew Fisher, Julia M. Brand, Christine Lei, Hong Sherman, Scott J. Chou, Ying-Hui Kuo, Phillip H. Tomography Article Evaluation of Parkinsonian Syndromes (PS) with Ioflupane iodine-123 dopamine transporter single photon emission computed tomography (DaT-SPECT), in conjunction with history and clinical examination, aids in diagnosis. FDA-approved, semi-quantitative software, DaTQUANT(TM) (GE Healthcare, Chicago, IL, USA) is available to assist in interpretation. This study aims to evaluate the optimal variables and thresholds of DaTQUANT to yield the optimal diagnostic accuracy. It is a retrospective review with three different patient populations. DaT-SPECT images from all three study groups were evaluated using DaTQUANT(TM) software, and both single and multi-variable logistic regression were used to model PS status. The optimal models were chosen via accuracy, sensitivity, and specificity, then evaluated on the other study groups. Among single variable models, the posterior putamen yielded the highest accuracy (84% to 95%), while balancing sensitivity and specificity. Multi-variable models did not substantially improve the accuracy. When the optimal single variable models for each group were used to evaluate the remaining two groups, comparable results were achieved. In typical utilization of DaT-SPECT for differentiation between nigrostriatal degenerative disease (NSDD) and non-NSDD, the posterior putamen was the single variable that yielded the highest accuracy across three different patient populations. The posterior putamen’s recommended thresholds for DaTQUANT are SBR ≤ 1.0, z-score of ≤−1.8 and percent deviation ≤ −0.34. MDPI 2021-12-18 /pmc/articles/PMC8706562/ /pubmed/34941653 http://dx.doi.org/10.3390/tomography7040081 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Neill, Matthew
Fisher, Julia M.
Brand, Christine
Lei, Hong
Sherman, Scott J.
Chou, Ying-Hui
Kuo, Phillip H.
Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title_full Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title_fullStr Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title_full_unstemmed Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title_short Practical Application of DaTQUANT with Optimal Threshold for Diagnostic Accuracy of Dopamine Transporter SPECT
title_sort practical application of datquant with optimal threshold for diagnostic accuracy of dopamine transporter spect
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8706562/
https://www.ncbi.nlm.nih.gov/pubmed/34941653
http://dx.doi.org/10.3390/tomography7040081
work_keys_str_mv AT neillmatthew practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT fisherjuliam practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT brandchristine practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT leihong practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT shermanscottj practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT chouyinghui practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect
AT kuophilliph practicalapplicationofdatquantwithoptimalthresholdfordiagnosticaccuracyofdopaminetransporterspect