Cargando…

A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation

In clinical practice, only a few reliable measurement instruments are available for monitoring knee joint rehabilitation. Advances to replace motion capturing with sensor data measurement have been made in the last years. Thus, a systematic review of the literature was performed, focusing on the imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Prill, Robert, Walter, Marina, Królikowska, Aleksandra, Becker, Roland
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707010/
https://www.ncbi.nlm.nih.gov/pubmed/34960315
http://dx.doi.org/10.3390/s21248221
_version_ 1784622331964948480
author Prill, Robert
Walter, Marina
Królikowska, Aleksandra
Becker, Roland
author_facet Prill, Robert
Walter, Marina
Królikowska, Aleksandra
Becker, Roland
author_sort Prill, Robert
collection PubMed
description In clinical practice, only a few reliable measurement instruments are available for monitoring knee joint rehabilitation. Advances to replace motion capturing with sensor data measurement have been made in the last years. Thus, a systematic review of the literature was performed, focusing on the implementation, diagnostic accuracy, and facilitators and barriers of integrating wearable sensor technology in clinical practices based on a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. For critical appraisal, the COSMIN Risk of Bias tool for reliability and measurement of error was used. PUBMED, Prospero, Cochrane database, and EMBASE were searched for eligible studies. Six studies reporting reliability aspects in using wearable sensor technology at any point after knee surgery in humans were included. All studies reported excellent results with high reliability coefficients, high limits of agreement, or a few detectable errors. They used different or partly inappropriate methods for estimating reliability or missed reporting essential information. Therefore, a moderate risk of bias must be considered. Further quality criterion studies in clinical settings are needed to synthesize the evidence for providing transparent recommendations for the clinical use of wearable movement sensors in knee joint rehabilitation.
format Online
Article
Text
id pubmed-8707010
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87070102021-12-25 A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation Prill, Robert Walter, Marina Królikowska, Aleksandra Becker, Roland Sensors (Basel) Systematic Review In clinical practice, only a few reliable measurement instruments are available for monitoring knee joint rehabilitation. Advances to replace motion capturing with sensor data measurement have been made in the last years. Thus, a systematic review of the literature was performed, focusing on the implementation, diagnostic accuracy, and facilitators and barriers of integrating wearable sensor technology in clinical practices based on a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. For critical appraisal, the COSMIN Risk of Bias tool for reliability and measurement of error was used. PUBMED, Prospero, Cochrane database, and EMBASE were searched for eligible studies. Six studies reporting reliability aspects in using wearable sensor technology at any point after knee surgery in humans were included. All studies reported excellent results with high reliability coefficients, high limits of agreement, or a few detectable errors. They used different or partly inappropriate methods for estimating reliability or missed reporting essential information. Therefore, a moderate risk of bias must be considered. Further quality criterion studies in clinical settings are needed to synthesize the evidence for providing transparent recommendations for the clinical use of wearable movement sensors in knee joint rehabilitation. MDPI 2021-12-09 /pmc/articles/PMC8707010/ /pubmed/34960315 http://dx.doi.org/10.3390/s21248221 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Prill, Robert
Walter, Marina
Królikowska, Aleksandra
Becker, Roland
A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title_full A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title_fullStr A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title_full_unstemmed A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title_short A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation
title_sort systematic review of diagnostic accuracy and clinical applications of wearable movement sensors for knee joint rehabilitation
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707010/
https://www.ncbi.nlm.nih.gov/pubmed/34960315
http://dx.doi.org/10.3390/s21248221
work_keys_str_mv AT prillrobert asystematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT waltermarina asystematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT krolikowskaaleksandra asystematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT beckerroland asystematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT prillrobert systematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT waltermarina systematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT krolikowskaaleksandra systematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation
AT beckerroland systematicreviewofdiagnosticaccuracyandclinicalapplicationsofwearablemovementsensorsforkneejointrehabilitation