Cargando…

Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application

Titanium (Ti)-based alloys (e.g., Ti6Al4V) are widely used in orthopedic implant applications owing to their excellent mechanical properties and biocompatibility. However, their corrosion resistance needs to be optimized. In addition, the presence of aluminum and vanadium cause alzheimer and cancer,...

Descripción completa

Detalles Bibliográficos
Autores principales: Azmat, Ambreen, Tufail, Muhammad, Chandio, Ali Dad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707149/
https://www.ncbi.nlm.nih.gov/pubmed/34947257
http://dx.doi.org/10.3390/ma14247660
_version_ 1784622366327832576
author Azmat, Ambreen
Tufail, Muhammad
Chandio, Ali Dad
author_facet Azmat, Ambreen
Tufail, Muhammad
Chandio, Ali Dad
author_sort Azmat, Ambreen
collection PubMed
description Titanium (Ti)-based alloys (e.g., Ti6Al4V) are widely used in orthopedic implant applications owing to their excellent mechanical properties and biocompatibility. However, their corrosion resistance needs to be optimized. In addition, the presence of aluminum and vanadium cause alzheimer and cancer, respectively. Therefore, in this study, titanium-based alloys were developed via powder metallurgy route. In these alloys, the Al and V were replaced with tin (Sn) which was the main aim of this study. Four sets of samples were prepared by varying Sn contents, i.e., 5 to 20 wt. %. This was followed by characterization techniques including laser particle analyzer (LPA), X-ray diffractometer (XRD), scanning electron microscope (SEM), computerized potentiostate, vicker hardness tester, and nanoindenter. Results demonstrate the powder sizes between 50 and 55 µm exhibiting very good densification after sintering. The alloy contained alpha at all concentrations of Sn. However, as Sn content in the alloy exceeded from 10 wt. %, the formation of intermetallic compounds was significant. Thus, the presence of such intermetallic phases are attributed to enhanced elastic modulus. In particular, when Sn content was between 15 and 20 wt. % a drastic increase in elastic modulus was observed thereby surpassing the standard/reference alloy (Ti6Al4V). However, at 10 wt. % of Sn, the elastic modulus is more or less comparable to reference counterpart. Similarly, hardness was also increased in an ascending order upon Sn addition, i.e., 250 to 310 HV. Specifically, at 10 wt. % Sn, the hardness was observed to be 250 HV which is quite near to reference alloy, i.e., 210 HV. Moreover, tensile strength (TS) of the alloys were calculated using hardness values since it was very difficult to prepare the test coupons using powders. The TS values were in the range of 975 to 1524 MPa at all concentrations of Sn. In particular, the TS at 10 wt. % Sn is 1149 MPa which is comparable to reference counterpart (1168 MPa). The corrosion rate of Titanium-Sn alloys (as of this study) and reference alloy, i.e., Ti6Al4V were also compared. Incorporation of Sn reduced the corrosion rate at large than that of reference counterpart. In particular, the trend was in decreasing order as Sn content increased from 5 to 20 wt. %. The minimum corrosion rate of 3.65 × 10(−9) mm/year was noticed at 20 wt. % than that of 0.03 mm/year of reference alloy. This shows the excellent corrosion resistance upon addition of Sn at all concentrations.
format Online
Article
Text
id pubmed-8707149
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87071492021-12-25 Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application Azmat, Ambreen Tufail, Muhammad Chandio, Ali Dad Materials (Basel) Article Titanium (Ti)-based alloys (e.g., Ti6Al4V) are widely used in orthopedic implant applications owing to their excellent mechanical properties and biocompatibility. However, their corrosion resistance needs to be optimized. In addition, the presence of aluminum and vanadium cause alzheimer and cancer, respectively. Therefore, in this study, titanium-based alloys were developed via powder metallurgy route. In these alloys, the Al and V were replaced with tin (Sn) which was the main aim of this study. Four sets of samples were prepared by varying Sn contents, i.e., 5 to 20 wt. %. This was followed by characterization techniques including laser particle analyzer (LPA), X-ray diffractometer (XRD), scanning electron microscope (SEM), computerized potentiostate, vicker hardness tester, and nanoindenter. Results demonstrate the powder sizes between 50 and 55 µm exhibiting very good densification after sintering. The alloy contained alpha at all concentrations of Sn. However, as Sn content in the alloy exceeded from 10 wt. %, the formation of intermetallic compounds was significant. Thus, the presence of such intermetallic phases are attributed to enhanced elastic modulus. In particular, when Sn content was between 15 and 20 wt. % a drastic increase in elastic modulus was observed thereby surpassing the standard/reference alloy (Ti6Al4V). However, at 10 wt. % of Sn, the elastic modulus is more or less comparable to reference counterpart. Similarly, hardness was also increased in an ascending order upon Sn addition, i.e., 250 to 310 HV. Specifically, at 10 wt. % Sn, the hardness was observed to be 250 HV which is quite near to reference alloy, i.e., 210 HV. Moreover, tensile strength (TS) of the alloys were calculated using hardness values since it was very difficult to prepare the test coupons using powders. The TS values were in the range of 975 to 1524 MPa at all concentrations of Sn. In particular, the TS at 10 wt. % Sn is 1149 MPa which is comparable to reference counterpart (1168 MPa). The corrosion rate of Titanium-Sn alloys (as of this study) and reference alloy, i.e., Ti6Al4V were also compared. Incorporation of Sn reduced the corrosion rate at large than that of reference counterpart. In particular, the trend was in decreasing order as Sn content increased from 5 to 20 wt. %. The minimum corrosion rate of 3.65 × 10(−9) mm/year was noticed at 20 wt. % than that of 0.03 mm/year of reference alloy. This shows the excellent corrosion resistance upon addition of Sn at all concentrations. MDPI 2021-12-12 /pmc/articles/PMC8707149/ /pubmed/34947257 http://dx.doi.org/10.3390/ma14247660 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Azmat, Ambreen
Tufail, Muhammad
Chandio, Ali Dad
Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title_full Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title_fullStr Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title_full_unstemmed Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title_short Synthesis and Characterization of Ti-Sn Alloy for Orthopedic Application
title_sort synthesis and characterization of ti-sn alloy for orthopedic application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707149/
https://www.ncbi.nlm.nih.gov/pubmed/34947257
http://dx.doi.org/10.3390/ma14247660
work_keys_str_mv AT azmatambreen synthesisandcharacterizationoftisnalloyfororthopedicapplication
AT tufailmuhammad synthesisandcharacterizationoftisnalloyfororthopedicapplication
AT chandioalidad synthesisandcharacterizationoftisnalloyfororthopedicapplication