Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications

Background and Objectives: Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboemboli...

Descripción completa

Detalles Bibliográficos
Autores principales: Lind, Alexander, Ahsan, Majid, Kaya, Elif, Wakili, Reza, Rassaf, Tienush, Jánosi, Rolf Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707306/
https://www.ncbi.nlm.nih.gov/pubmed/34946276
http://dx.doi.org/10.3390/medicina57121331
_version_ 1784622404433084416
author Lind, Alexander
Ahsan, Majid
Kaya, Elif
Wakili, Reza
Rassaf, Tienush
Jánosi, Rolf Alexander
author_facet Lind, Alexander
Ahsan, Majid
Kaya, Elif
Wakili, Reza
Rassaf, Tienush
Jánosi, Rolf Alexander
author_sort Lind, Alexander
collection PubMed
description Background and Objectives: Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboembolic events due to TAVR implantation, high incidence of coronary artery diseases (CAD) with the necessity of coronary intervention, and high rate of atrial fibrillation with the need of stroke prevention. We sought to evaluate the safety, efficiency, and clinical outcomes of early PPI following TAVR using the PlasmaBlade™ (Medtronic Inc., Minneapolis, MN, USA) pulsed electron avalanche knife (PEAK) for bleeding control in patients under DAPT or OAK. Materials and Methods: This retrospective single-center study included patients who underwent PPI after transfemoral TAVR (TF) at our center between December 2015 and May 2020. All PPI were performed using the PlasmaBlade™ Device. Results: The overall PPI rate was 14.1% (83 of 587 patients; 82.5 ± 4.6 years; 45.8% male). The PPI procedures were used to treat high-grade atrioventricular block (81.9%), severe sinus node dysfunction (13.3%), and alternating bundle branch block (4.8%). At the time of the procedure, 35 (42.2%) patients received DAPT, and 48 (57.8%) patients received OAK (50% with vitamin K antagonist (VKA) and 50% with novel oral anticoagulants (NOAK)). One device-pocket hematoma treated conservatively occurred in a patient (1.2%) receiving NOAK. Two re-operations were necessary in patients due to immediate lead dislocation (2.4%). Conclusions: The results of this study illustrate that the use of PlasmaBlade™ for PPI in patients after a TAVR who require antithrombotic treatment is feasible and might result into lower rates of severe bleeding complications compared to rates reported in the literature. Use of the PlasmaBlade device may be considered in this specific group of patients because of their high risk of bleeding.
format Online
Article
Text
id pubmed-8707306
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87073062021-12-25 Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications Lind, Alexander Ahsan, Majid Kaya, Elif Wakili, Reza Rassaf, Tienush Jánosi, Rolf Alexander Medicina (Kaunas) Article Background and Objectives: Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboembolic events due to TAVR implantation, high incidence of coronary artery diseases (CAD) with the necessity of coronary intervention, and high rate of atrial fibrillation with the need of stroke prevention. We sought to evaluate the safety, efficiency, and clinical outcomes of early PPI following TAVR using the PlasmaBlade™ (Medtronic Inc., Minneapolis, MN, USA) pulsed electron avalanche knife (PEAK) for bleeding control in patients under DAPT or OAK. Materials and Methods: This retrospective single-center study included patients who underwent PPI after transfemoral TAVR (TF) at our center between December 2015 and May 2020. All PPI were performed using the PlasmaBlade™ Device. Results: The overall PPI rate was 14.1% (83 of 587 patients; 82.5 ± 4.6 years; 45.8% male). The PPI procedures were used to treat high-grade atrioventricular block (81.9%), severe sinus node dysfunction (13.3%), and alternating bundle branch block (4.8%). At the time of the procedure, 35 (42.2%) patients received DAPT, and 48 (57.8%) patients received OAK (50% with vitamin K antagonist (VKA) and 50% with novel oral anticoagulants (NOAK)). One device-pocket hematoma treated conservatively occurred in a patient (1.2%) receiving NOAK. Two re-operations were necessary in patients due to immediate lead dislocation (2.4%). Conclusions: The results of this study illustrate that the use of PlasmaBlade™ for PPI in patients after a TAVR who require antithrombotic treatment is feasible and might result into lower rates of severe bleeding complications compared to rates reported in the literature. Use of the PlasmaBlade device may be considered in this specific group of patients because of their high risk of bleeding. MDPI 2021-12-05 /pmc/articles/PMC8707306/ /pubmed/34946276 http://dx.doi.org/10.3390/medicina57121331 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lind, Alexander
Ahsan, Majid
Kaya, Elif
Wakili, Reza
Rassaf, Tienush
Jánosi, Rolf Alexander
Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title_full Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title_fullStr Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title_full_unstemmed Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title_short Early Pacemaker Implantation after Transcatheter Aortic Valve Replacement: Impact of PlasmaBlade™ for Prevention of Device-Associated Bleeding Complications
title_sort early pacemaker implantation after transcatheter aortic valve replacement: impact of plasmablade™ for prevention of device-associated bleeding complications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707306/
https://www.ncbi.nlm.nih.gov/pubmed/34946276
http://dx.doi.org/10.3390/medicina57121331
work_keys_str_mv AT lindalexander earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications
AT ahsanmajid earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications
AT kayaelif earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications
AT wakilireza earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications
AT rassaftienush earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications
AT janosirolfalexander earlypacemakerimplantationaftertranscatheteraorticvalvereplacementimpactofplasmabladeforpreventionofdeviceassociatedbleedingcomplications