Cargando…

Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel

AISI H13 die steel specimens were subjected to heating at 1020 °C followed by oil quenching and double tempering at 520 °C. Subsequently, these specimens were subjected to deep cryogenic treatment at −185 °C in liquid nitrogen environment for 16 h and then subjected to soft tempering at 100 °C once...

Descripción completa

Detalles Bibliográficos
Autores principales: Shinde, Tarang, Pruncu, Catalin, Dhokey, Narendra B., Parau, Anca C., Vladescu, Alina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707492/
https://www.ncbi.nlm.nih.gov/pubmed/34947456
http://dx.doi.org/10.3390/ma14247863
_version_ 1784622450041946112
author Shinde, Tarang
Pruncu, Catalin
Dhokey, Narendra B.
Parau, Anca C.
Vladescu, Alina
author_facet Shinde, Tarang
Pruncu, Catalin
Dhokey, Narendra B.
Parau, Anca C.
Vladescu, Alina
author_sort Shinde, Tarang
collection PubMed
description AISI H13 die steel specimens were subjected to heating at 1020 °C followed by oil quenching and double tempering at 520 °C. Subsequently, these specimens were subjected to deep cryogenic treatment at −185 °C in liquid nitrogen environment for 16 h and then subjected to soft tempering at 100 °C once the specimens attained room temperature. Thereafter, the specimens were subjected to scanning electron microscopy (SEM) analysis and electron backscatter diffraction (EBSD) analysis. The electrochemical corrosion activity was investigated in 3.5% NaCl at 23 ± 0.5 °C by evaluating the evolution of open circuit potential over time and potentiodynamic curves, and electrochemical impedance spectroscopy study was also carried out. The heat-treated specimens exhibited better resistance to corrosion through more electropositive values of open circuit potential. This could be attributed to lower grain boundary area in heat-treated specimens as compared to 16 h cryogenically treated specimen as higher grain boundary areas behave as an anode in an electrochemical cell, thereby enhancing the rate of corrosion. According to electrochemical tests, the cryogenically treated surface is more resistant to corrosion, followed by heated alloy. However, both surface modification treatments improved the corrosion behavior of the untreated alloy.
format Online
Article
Text
id pubmed-8707492
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87074922021-12-25 Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel Shinde, Tarang Pruncu, Catalin Dhokey, Narendra B. Parau, Anca C. Vladescu, Alina Materials (Basel) Article AISI H13 die steel specimens were subjected to heating at 1020 °C followed by oil quenching and double tempering at 520 °C. Subsequently, these specimens were subjected to deep cryogenic treatment at −185 °C in liquid nitrogen environment for 16 h and then subjected to soft tempering at 100 °C once the specimens attained room temperature. Thereafter, the specimens were subjected to scanning electron microscopy (SEM) analysis and electron backscatter diffraction (EBSD) analysis. The electrochemical corrosion activity was investigated in 3.5% NaCl at 23 ± 0.5 °C by evaluating the evolution of open circuit potential over time and potentiodynamic curves, and electrochemical impedance spectroscopy study was also carried out. The heat-treated specimens exhibited better resistance to corrosion through more electropositive values of open circuit potential. This could be attributed to lower grain boundary area in heat-treated specimens as compared to 16 h cryogenically treated specimen as higher grain boundary areas behave as an anode in an electrochemical cell, thereby enhancing the rate of corrosion. According to electrochemical tests, the cryogenically treated surface is more resistant to corrosion, followed by heated alloy. However, both surface modification treatments improved the corrosion behavior of the untreated alloy. MDPI 2021-12-18 /pmc/articles/PMC8707492/ /pubmed/34947456 http://dx.doi.org/10.3390/ma14247863 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shinde, Tarang
Pruncu, Catalin
Dhokey, Narendra B.
Parau, Anca C.
Vladescu, Alina
Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title_full Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title_fullStr Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title_full_unstemmed Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title_short Effect of Deep Cryogenic Treatment on Corrosion Behavior of AISI H13 Die Steel
title_sort effect of deep cryogenic treatment on corrosion behavior of aisi h13 die steel
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707492/
https://www.ncbi.nlm.nih.gov/pubmed/34947456
http://dx.doi.org/10.3390/ma14247863
work_keys_str_mv AT shindetarang effectofdeepcryogenictreatmentoncorrosionbehaviorofaisih13diesteel
AT pruncucatalin effectofdeepcryogenictreatmentoncorrosionbehaviorofaisih13diesteel
AT dhokeynarendrab effectofdeepcryogenictreatmentoncorrosionbehaviorofaisih13diesteel
AT parauancac effectofdeepcryogenictreatmentoncorrosionbehaviorofaisih13diesteel
AT vladescualina effectofdeepcryogenictreatmentoncorrosionbehaviorofaisih13diesteel