Cargando…
Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods
Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (G...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707963/ https://www.ncbi.nlm.nih.gov/pubmed/34945369 http://dx.doi.org/10.3390/mi12121519 |
_version_ | 1784622566508331008 |
---|---|
author | Liu, Jin-Guang Wan, Jia-Zheng Lin, Qing-Min Han, Guo-Cheng Feng, Xiao-Zhen Chen, Zhencheng |
author_facet | Liu, Jin-Guang Wan, Jia-Zheng Lin, Qing-Min Han, Guo-Cheng Feng, Xiao-Zhen Chen, Zhencheng |
author_sort | Liu, Jin-Guang |
collection | PubMed |
description | Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L(−1) according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L(−1) and its sensitivity was 0.12 μA·μM(−1)·cm(−2), which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L(−1) and a sensitivity of 0.09 μA·μM(−1)·cm(−2). Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples. |
format | Online Article Text |
id | pubmed-8707963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87079632021-12-25 Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods Liu, Jin-Guang Wan, Jia-Zheng Lin, Qing-Min Han, Guo-Cheng Feng, Xiao-Zhen Chen, Zhencheng Micromachines (Basel) Article Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L(−1) according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L(−1) and its sensitivity was 0.12 μA·μM(−1)·cm(−2), which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L(−1) and a sensitivity of 0.09 μA·μM(−1)·cm(−2). Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples. MDPI 2021-12-07 /pmc/articles/PMC8707963/ /pubmed/34945369 http://dx.doi.org/10.3390/mi12121519 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Jin-Guang Wan, Jia-Zheng Lin, Qing-Min Han, Guo-Cheng Feng, Xiao-Zhen Chen, Zhencheng Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title | Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title_full | Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title_fullStr | Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title_full_unstemmed | Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title_short | Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods |
title_sort | convenient heme nanorod modified electrode for quercetin sensing by two common electrochemical methods |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8707963/ https://www.ncbi.nlm.nih.gov/pubmed/34945369 http://dx.doi.org/10.3390/mi12121519 |
work_keys_str_mv | AT liujinguang convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods AT wanjiazheng convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods AT linqingmin convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods AT hanguocheng convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods AT fengxiaozhen convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods AT chenzhencheng convenienthemenanorodmodifiedelectrodeforquercetinsensingbytwocommonelectrochemicalmethods |