The present review aimed to evaluate the difference of dental implant failure rates and marginal bone loss (MBL) between implants inserted in fresh extraction sockets or healed sites. Electronic search was undertaken in three databases, plus manual search of journals, including studies randomized or...

Descripción completa

Detalles Bibliográficos
Autores principales: Ibrahim, Adam, Chrcanovic, Bruno Ramos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8708389/
https://www.ncbi.nlm.nih.gov/pubmed/34947493
http://dx.doi.org/10.3390/ma14247903
_version_ 1784622672757391360
author Ibrahim, Adam
Chrcanovic, Bruno Ramos
author_facet Ibrahim, Adam
Chrcanovic, Bruno Ramos
author_sort Ibrahim, Adam
collection PubMed
description The present review aimed to evaluate the difference of dental implant failure rates and marginal bone loss (MBL) between implants inserted in fresh extraction sockets or healed sites. Electronic search was undertaken in three databases, plus manual search of journals, including studies randomized or not. Meta-analyses were performed besides meta-regressions, in order to verify how the odds ratio (OR) and MBL were associated with follow-up time. The review included 163 publications. Altogether, there were 17,278 and 38,738 implants placed in fresh extraction sockets and healed sites, respectively. Pairwise meta-analyses showed that implants in sockets had a higher failure risk in comparison to healed sites: OR 1.349, all studies included; OR 2.070, only prospective non-RCTs; OR 2.487, only RCTs (all p < 0.001). The difference in implant failure between the groups was statistically significant in the maxilla (OR 1.616, p = 0.029), but not in the mandible (OR 2.192, p = 0.075). The MBL mean difference (MD) between the groups was −0.053 mm (p = 0.089). There was an estimated decrease of 0.003 in OR (p = 0.284) and an increase of 0.006 mm (p = 0.036) in the MBL MD between groups for every additional month of follow-up. In conclusion, implants placed in fresh extraction sockets present higher risk of failure than implants placed in healed sites.
format Online
Article
Text
id pubmed-8708389
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87083892021-12-25 Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis Ibrahim, Adam Chrcanovic, Bruno Ramos Materials (Basel) Review The present review aimed to evaluate the difference of dental implant failure rates and marginal bone loss (MBL) between implants inserted in fresh extraction sockets or healed sites. Electronic search was undertaken in three databases, plus manual search of journals, including studies randomized or not. Meta-analyses were performed besides meta-regressions, in order to verify how the odds ratio (OR) and MBL were associated with follow-up time. The review included 163 publications. Altogether, there were 17,278 and 38,738 implants placed in fresh extraction sockets and healed sites, respectively. Pairwise meta-analyses showed that implants in sockets had a higher failure risk in comparison to healed sites: OR 1.349, all studies included; OR 2.070, only prospective non-RCTs; OR 2.487, only RCTs (all p < 0.001). The difference in implant failure between the groups was statistically significant in the maxilla (OR 1.616, p = 0.029), but not in the mandible (OR 2.192, p = 0.075). The MBL mean difference (MD) between the groups was −0.053 mm (p = 0.089). There was an estimated decrease of 0.003 in OR (p = 0.284) and an increase of 0.006 mm (p = 0.036) in the MBL MD between groups for every additional month of follow-up. In conclusion, implants placed in fresh extraction sockets present higher risk of failure than implants placed in healed sites. MDPI 2021-12-20 /pmc/articles/PMC8708389/ /pubmed/34947493 http://dx.doi.org/10.3390/ma14247903 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Ibrahim, Adam
Chrcanovic, Bruno Ramos
Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title_full Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title_fullStr Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title_full_unstemmed Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title_short Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis
title_sort dental implants inserted in fresh extraction sockets versus healed sites: a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8708389/
https://www.ncbi.nlm.nih.gov/pubmed/34947493
http://dx.doi.org/10.3390/ma14247903
work_keys_str_mv AT ibrahimadam dentalimplantsinsertedinfreshextractionsocketsversushealedsitesasystematicreviewandmetaanalysis
AT chrcanovicbrunoramos dentalimplantsinsertedinfreshextractionsocketsversushealedsitesasystematicreviewandmetaanalysis