Cargando…

Plaque Characterization with Computed Tomography Angiography Based on a Diluted-contrast Injection Protocol

OBJECTIVE: Coronary plaques with low attenuation on computed tomography (CT) angiography may indicate vulnerable plaques. However, plaque CT attenuation is reported to be significantly affected by intracoronary attenuation. Recently, the diluted-contrast injection protocol was established to facilit...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakao, Yasuhisa, Yoshida, Kazuki, Inaba, Shinji, Tanabe, Yuki, Kurata, Akira, Uetani, Teruyoshi, Kido, Teruhito, Inoue, Katsuji, Mochizuki, Teruhito, Yamaguchi, Osamu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Internal Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8710393/
https://www.ncbi.nlm.nih.gov/pubmed/34853256
http://dx.doi.org/10.2169/internalmedicine.6683-20
Descripción
Sumario:OBJECTIVE: Coronary plaques with low attenuation on computed tomography (CT) angiography may indicate vulnerable plaques. However, plaque CT attenuation is reported to be significantly affected by intracoronary attenuation. Recently, the diluted-contrast injection protocol was established to facilitate more uniform intracoronary attenuation than can be achieved with the generally used body-weight-adjusted protocol. We validated the relationship between low-attenuation plaque on CT and lipid-rich plaque using integrated backscatter-intravascular ultrasound (IB-IVUS) as the standard reference. METHODS: Plaques were divided into tertiles (T1, T2, and T3) according to the plaque CT attenuation, calculated as the average of five intra-plaque regions of interest, and compared with the plaque characteristics noted on IB-IVUS. PATIENTS: Patients who underwent both CT angiography using a diluted-contrast injection protocol and IB-IVUS were retrospectively analyzed. RESULTS: Thirty-nine plaques in 32 patients were analyzed by CT angiography and IB-IVUS. The median plaque CT attenuation (Hounsfield units) of each tertile was 30 (T1), 48 (T2), and 68 (T3). Although no significant difference was noted in conventional quantitative IVUS parameters (e.g. plaque burden), the T1 with lowest plaque CT attenuation had the highest percentage lipid area by IB-IVUS [75.1% (T1), 57.8% (T2), and 50.8% (T3), respectively, p<0.01]. Furthermore, the plaque CT attenuation had a significant negative correlation with the percentage lipid area (r=-0.59, p<0.01). CONCLUSION: CT angiography-based plaque characterization using a diluted-contrast injection protocol may aid in the quantitative detection of lipid-rich plaque.