Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711235/ https://www.ncbi.nlm.nih.gov/pubmed/34966792 http://dx.doi.org/10.3389/fcvm.2021.736877 |
_version_ | 1784623330255437824 |
---|---|
author | Chen, Jinmiao Lv, Minzhi Lu, Yuntao Fu, Jiahui Guo, Yingqiang Tao, Liang Zhou, Xinmin Gu, Tianxiang Wei, Lai Hong, Tao Wang, Chunsheng |
author_facet | Chen, Jinmiao Lv, Minzhi Lu, Yuntao Fu, Jiahui Guo, Yingqiang Tao, Liang Zhou, Xinmin Gu, Tianxiang Wei, Lai Hong, Tao Wang, Chunsheng |
author_sort | Chen, Jinmiao |
collection | PubMed |
description | Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory. Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm(2). For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm(2) and 1.8 ± 0.2 cm(2) were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm(2), respectively. There was no significant change between 1-year and 2-year hemodynamic performance. Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability. |
format | Online Article Text |
id | pubmed-8711235 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-87112352021-12-28 Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve Chen, Jinmiao Lv, Minzhi Lu, Yuntao Fu, Jiahui Guo, Yingqiang Tao, Liang Zhou, Xinmin Gu, Tianxiang Wei, Lai Hong, Tao Wang, Chunsheng Front Cardiovasc Med Cardiovascular Medicine Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory. Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm(2). For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm(2) and 1.8 ± 0.2 cm(2) were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm(2), respectively. There was no significant change between 1-year and 2-year hemodynamic performance. Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability. Frontiers Media S.A. 2021-12-13 /pmc/articles/PMC8711235/ /pubmed/34966792 http://dx.doi.org/10.3389/fcvm.2021.736877 Text en Copyright © 2021 Chen, Lv, Lu, Fu, Guo, Tao, Zhou, Gu, Wei, Hong and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Chen, Jinmiao Lv, Minzhi Lu, Yuntao Fu, Jiahui Guo, Yingqiang Tao, Liang Zhou, Xinmin Gu, Tianxiang Wei, Lai Hong, Tao Wang, Chunsheng Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title | Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title_full | Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title_fullStr | Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title_full_unstemmed | Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title_short | Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve |
title_sort | two-year clinical follow-up assessment of the novel cingular surgical bovine pericardial valve |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711235/ https://www.ncbi.nlm.nih.gov/pubmed/34966792 http://dx.doi.org/10.3389/fcvm.2021.736877 |
work_keys_str_mv | AT chenjinmiao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT lvminzhi twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT luyuntao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT fujiahui twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT guoyingqiang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT taoliang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT zhouxinmin twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT gutianxiang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT weilai twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT hongtao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve AT wangchunsheng twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve |