Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve

Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jinmiao, Lv, Minzhi, Lu, Yuntao, Fu, Jiahui, Guo, Yingqiang, Tao, Liang, Zhou, Xinmin, Gu, Tianxiang, Wei, Lai, Hong, Tao, Wang, Chunsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711235/
https://www.ncbi.nlm.nih.gov/pubmed/34966792
http://dx.doi.org/10.3389/fcvm.2021.736877
_version_ 1784623330255437824
author Chen, Jinmiao
Lv, Minzhi
Lu, Yuntao
Fu, Jiahui
Guo, Yingqiang
Tao, Liang
Zhou, Xinmin
Gu, Tianxiang
Wei, Lai
Hong, Tao
Wang, Chunsheng
author_facet Chen, Jinmiao
Lv, Minzhi
Lu, Yuntao
Fu, Jiahui
Guo, Yingqiang
Tao, Liang
Zhou, Xinmin
Gu, Tianxiang
Wei, Lai
Hong, Tao
Wang, Chunsheng
author_sort Chen, Jinmiao
collection PubMed
description Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory. Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm(2). For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm(2) and 1.8 ± 0.2 cm(2) were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm(2), respectively. There was no significant change between 1-year and 2-year hemodynamic performance. Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability.
format Online
Article
Text
id pubmed-8711235
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87112352021-12-28 Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve Chen, Jinmiao Lv, Minzhi Lu, Yuntao Fu, Jiahui Guo, Yingqiang Tao, Liang Zhou, Xinmin Gu, Tianxiang Wei, Lai Hong, Tao Wang, Chunsheng Front Cardiovasc Med Cardiovascular Medicine Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis. Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory. Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm(2). For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm(2) and 1.8 ± 0.2 cm(2) were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm(2), respectively. There was no significant change between 1-year and 2-year hemodynamic performance. Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability. Frontiers Media S.A. 2021-12-13 /pmc/articles/PMC8711235/ /pubmed/34966792 http://dx.doi.org/10.3389/fcvm.2021.736877 Text en Copyright © 2021 Chen, Lv, Lu, Fu, Guo, Tao, Zhou, Gu, Wei, Hong and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Chen, Jinmiao
Lv, Minzhi
Lu, Yuntao
Fu, Jiahui
Guo, Yingqiang
Tao, Liang
Zhou, Xinmin
Gu, Tianxiang
Wei, Lai
Hong, Tao
Wang, Chunsheng
Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title_full Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title_fullStr Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title_full_unstemmed Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title_short Two-Year Clinical Follow-Up Assessment of the Novel Cingular Surgical Bovine Pericardial Valve
title_sort two-year clinical follow-up assessment of the novel cingular surgical bovine pericardial valve
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711235/
https://www.ncbi.nlm.nih.gov/pubmed/34966792
http://dx.doi.org/10.3389/fcvm.2021.736877
work_keys_str_mv AT chenjinmiao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT lvminzhi twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT luyuntao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT fujiahui twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT guoyingqiang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT taoliang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT zhouxinmin twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT gutianxiang twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT weilai twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT hongtao twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve
AT wangchunsheng twoyearclinicalfollowupassessmentofthenovelcingularsurgicalbovinepericardialvalve