Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice
Using digitalized whole slide images (WSI) in routine histopathology practice is a revolutionary technology. This study aims to assess the clinical impacts of WSI quality and representation of the corresponding glass slides. 40,160 breast WSIs were examined and compared with their corresponding glas...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group US
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711290/ https://www.ncbi.nlm.nih.gov/pubmed/34961765 http://dx.doi.org/10.1038/s41379-021-01000-8 |
_version_ | 1784623340272484352 |
---|---|
author | Atallah, Nehal M. Toss, Michael S. Verrill, Clare Salto-Tellez, Manuel Snead, David Rakha, Emad A. |
author_facet | Atallah, Nehal M. Toss, Michael S. Verrill, Clare Salto-Tellez, Manuel Snead, David Rakha, Emad A. |
author_sort | Atallah, Nehal M. |
collection | PubMed |
description | Using digitalized whole slide images (WSI) in routine histopathology practice is a revolutionary technology. This study aims to assess the clinical impacts of WSI quality and representation of the corresponding glass slides. 40,160 breast WSIs were examined and compared with their corresponding glass slides. The presence, frequency, location, tissue type, and the clinical impacts of missing tissue were assessed. Scanning time, type of the specimens, time to WSIs implementation, and quality control (QC) measures were also considered. The frequency of missing tissue ranged from 2% to 19%. The area size of the missed tissue ranged from 1–70%. In most cases (>75%), the missing tissue area size was <10% and peripherally located. In all cases the missed tissue was fat with or without small entrapped normal breast parenchyma. No missing tissue was identified in WSIs of the core biopsy specimens. QC measures improved images quality and reduced WSI failure rates by seven-fold. A negative linear correlation between the frequency of missing tissue and both the scanning time and the image file size was observed (p < 0.05). None of the WSI with missing tissues resulted in a change in the final diagnosis. Missing tissue on breast WSI is observed but with variable frequency and little diagnostic consequence. Balancing between WSI quality and scanning time/image file size should be considered and pathology laboratories should undertake their own assessments of risk and provide the relevant mitigations with the appropriate level of caution. |
format | Online Article Text |
id | pubmed-8711290 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group US |
record_format | MEDLINE/PubMed |
spelling | pubmed-87112902021-12-28 Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice Atallah, Nehal M. Toss, Michael S. Verrill, Clare Salto-Tellez, Manuel Snead, David Rakha, Emad A. Mod Pathol Article Using digitalized whole slide images (WSI) in routine histopathology practice is a revolutionary technology. This study aims to assess the clinical impacts of WSI quality and representation of the corresponding glass slides. 40,160 breast WSIs were examined and compared with their corresponding glass slides. The presence, frequency, location, tissue type, and the clinical impacts of missing tissue were assessed. Scanning time, type of the specimens, time to WSIs implementation, and quality control (QC) measures were also considered. The frequency of missing tissue ranged from 2% to 19%. The area size of the missed tissue ranged from 1–70%. In most cases (>75%), the missing tissue area size was <10% and peripherally located. In all cases the missed tissue was fat with or without small entrapped normal breast parenchyma. No missing tissue was identified in WSIs of the core biopsy specimens. QC measures improved images quality and reduced WSI failure rates by seven-fold. A negative linear correlation between the frequency of missing tissue and both the scanning time and the image file size was observed (p < 0.05). None of the WSI with missing tissues resulted in a change in the final diagnosis. Missing tissue on breast WSI is observed but with variable frequency and little diagnostic consequence. Balancing between WSI quality and scanning time/image file size should be considered and pathology laboratories should undertake their own assessments of risk and provide the relevant mitigations with the appropriate level of caution. Nature Publishing Group US 2021-12-27 2022 /pmc/articles/PMC8711290/ /pubmed/34961765 http://dx.doi.org/10.1038/s41379-021-01000-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Atallah, Nehal M. Toss, Michael S. Verrill, Clare Salto-Tellez, Manuel Snead, David Rakha, Emad A. Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title | Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title_full | Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title_fullStr | Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title_full_unstemmed | Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title_short | Potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
title_sort | potential quality pitfalls of digitalized whole slide image of breast pathology in routine practice |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8711290/ https://www.ncbi.nlm.nih.gov/pubmed/34961765 http://dx.doi.org/10.1038/s41379-021-01000-8 |
work_keys_str_mv | AT atallahnehalm potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice AT tossmichaels potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice AT verrillclare potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice AT saltotellezmanuel potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice AT sneaddavid potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice AT rakhaemada potentialqualitypitfallsofdigitalizedwholeslideimageofbreastpathologyinroutinepractice |