Cargando…

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

PURPOSE: This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS: For the fabrication of 3-unit monolithic zirconia restorations using i...

Descripción completa

Detalles Bibliográficos
Autores principales: Özal, Çise, Ulusoy, Mutahhar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8712113/
https://www.ncbi.nlm.nih.gov/pubmed/35003553
http://dx.doi.org/10.4047/jap.2021.13.6.373
_version_ 1784623494867189760
author Özal, Çise
Ulusoy, Mutahhar
author_facet Özal, Çise
Ulusoy, Mutahhar
author_sort Özal, Çise
collection PubMed
description PURPOSE: This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS: For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in µm) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS: In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 µm) and axial (92.4 ± 14.8 µm), and T4 had the lowest axio-occlusal (89.4 ± 15.6 µm) and occlusal (89.1 ± 13.9 µm) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION: Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 µm), except D900L.
format Online
Article
Text
id pubmed-8712113
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-87121132022-01-06 In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies Özal, Çise Ulusoy, Mutahhar J Adv Prosthodont Original Article PURPOSE: This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS: For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in µm) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS: In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 µm) and axial (92.4 ± 14.8 µm), and T4 had the lowest axio-occlusal (89.4 ± 15.6 µm) and occlusal (89.1 ± 13.9 µm) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION: Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 µm), except D900L. The Korean Academy of Prosthodontics 2021-12 2021-12-22 /pmc/articles/PMC8712113/ /pubmed/35003553 http://dx.doi.org/10.4047/jap.2021.13.6.373 Text en © 2021 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Özal, Çise
Ulusoy, Mutahhar
In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title_full In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title_fullStr In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title_full_unstemmed In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title_short In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
title_sort in-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8712113/
https://www.ncbi.nlm.nih.gov/pubmed/35003553
http://dx.doi.org/10.4047/jap.2021.13.6.373
work_keys_str_mv AT ozalcise invitroevaluationofmarginalandinternalfitof3unitmonolithiczirconiarestorationsfabricatedusingdigitalscanningtechnologies
AT ulusoymutahhar invitroevaluationofmarginalandinternalfitof3unitmonolithiczirconiarestorationsfabricatedusingdigitalscanningtechnologies