Cargando…

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

PURPOSE: The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS: A titanium implant was inserted at position of lower...

Descripción completa

Detalles Bibliográficos
Autores principales: Graf, Tobias, Güth, Jan-Frederik, Diegritz, Christian, Liebermann, Anja, Schweiger, Josef, Schubert, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8712114/
https://www.ncbi.nlm.nih.gov/pubmed/35003551
http://dx.doi.org/10.4047/jap.2021.13.6.351
_version_ 1784623495102070784
author Graf, Tobias
Güth, Jan-Frederik
Diegritz, Christian
Liebermann, Anja
Schweiger, Josef
Schubert, Oliver
author_facet Graf, Tobias
Güth, Jan-Frederik
Diegritz, Christian
Liebermann, Anja
Schweiger, Josef
Schubert, Oliver
author_sort Graf, Tobias
collection PubMed
description PURPOSE: The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS: A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS: Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 µm in group CF and 34 ± 6 µm in group PC. RMSE of total adjustments was 61 ± 11 µm in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION: Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.
format Online
Article
Text
id pubmed-8712114
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-87121142022-01-06 Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based Graf, Tobias Güth, Jan-Frederik Diegritz, Christian Liebermann, Anja Schweiger, Josef Schubert, Oliver J Adv Prosthodont Original Article PURPOSE: The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS: A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS: Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 µm in group CF and 34 ± 6 µm in group PC. RMSE of total adjustments was 61 ± 11 µm in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION: Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable. The Korean Academy of Prosthodontics 2021-12 2021-12-22 /pmc/articles/PMC8712114/ /pubmed/35003551 http://dx.doi.org/10.4047/jap.2021.13.6.351 Text en © 2021 The Korean Academy of Prosthodontics https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Graf, Tobias
Güth, Jan-Frederik
Diegritz, Christian
Liebermann, Anja
Schweiger, Josef
Schubert, Oliver
Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title_full Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title_fullStr Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title_full_unstemmed Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title_short Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based
title_sort efficiency of occlusal and interproximal adjustments in cad-cam manufactured single implant crowns - cast-free vs 3d printed cast-based
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8712114/
https://www.ncbi.nlm.nih.gov/pubmed/35003551
http://dx.doi.org/10.4047/jap.2021.13.6.351
work_keys_str_mv AT graftobias efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased
AT guthjanfrederik efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased
AT diegritzchristian efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased
AT liebermannanja efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased
AT schweigerjosef efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased
AT schubertoliver efficiencyofocclusalandinterproximaladjustmentsincadcammanufacturedsingleimplantcrownscastfreevs3dprintedcastbased