Cargando…

Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli

Background Timely initiation of antimicrobial therapy in patients with blood stream infection is absolutely necessary to reduce mortality and morbidity. Most clinical microbiology laboratories use conventional methods for identification and antimicrobial susceptibility testing (AST) that involve bio...

Descripción completa

Detalles Bibliográficos
Autores principales: Kavipriya, D, Prakash, Suman Susan, Dhandapani, Sarumathi, Rajshekar, Deepashree, Sastry, Apurba Sankar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Pvt. Ltd. 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8714412/
https://www.ncbi.nlm.nih.gov/pubmed/34975259
http://dx.doi.org/10.1055/s-0041-1732489
_version_ 1784623909630377984
author Kavipriya, D
Prakash, Suman Susan
Dhandapani, Sarumathi
Rajshekar, Deepashree
Sastry, Apurba Sankar
author_facet Kavipriya, D
Prakash, Suman Susan
Dhandapani, Sarumathi
Rajshekar, Deepashree
Sastry, Apurba Sankar
author_sort Kavipriya, D
collection PubMed
description Background Timely initiation of antimicrobial therapy in patients with blood stream infection is absolutely necessary to reduce mortality and morbidity. Most clinical microbiology laboratories use conventional methods for identification and antimicrobial susceptibility testing (AST) that involve biochemical methods for identification followed by AST by disk diffusion. The aim of the current study is to assess the various errors associated with direct susceptibility testing done from blood culture broth using automated AST system-Vitek-2 compact compared with the reference method of AST done from bacterial colonies. Materials and Methods The study was conducted in a tertiary care public sector 2,200-bedded hospital in South India for a period of 6 months. The study involved positively flagged blood culture bottles that yielded single morphotype of Gram-negative organism by Gram stain. A total of 120 bacterial isolates were collected that consisted of consecutively obtained first 60 isolates of Enterobacteriaceae family (30 Escherichia coli and 30 Klebsiella pneumoniae ) and consecutively obtained first 60 nonfermenters (30 Pseudomonas aeruginosa and 30 Acinetobacter baumannii). Vitek-2 AST was done from these 120 blood culture broth, following the protocol by Biomerieux, and results were obtained. Then, Vitek-2 was done from colonies (reference method) using appropriate panel for Enterobacteriaceae and nonfermenters, and results were obtained. Both the results were compared. Results Nonfermenters showed a better categorical agreement of 97.6%, as compared to Enterobacteriaceae, which showed 97%. Among Enterobacteriaceae, both E. coli and K. pneumoniae showed categorical agreement of 97% each. Conclusion The procedure of AST directly from blood culture broth represents a simple and effective technique that can reduce the turnaround time by 24 hours, which in turn benefits the clinician in appropriate utilization of antimicrobials for better patient care.
format Online
Article
Text
id pubmed-8714412
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-87144122021-12-30 Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli Kavipriya, D Prakash, Suman Susan Dhandapani, Sarumathi Rajshekar, Deepashree Sastry, Apurba Sankar J Lab Physicians Background Timely initiation of antimicrobial therapy in patients with blood stream infection is absolutely necessary to reduce mortality and morbidity. Most clinical microbiology laboratories use conventional methods for identification and antimicrobial susceptibility testing (AST) that involve biochemical methods for identification followed by AST by disk diffusion. The aim of the current study is to assess the various errors associated with direct susceptibility testing done from blood culture broth using automated AST system-Vitek-2 compact compared with the reference method of AST done from bacterial colonies. Materials and Methods The study was conducted in a tertiary care public sector 2,200-bedded hospital in South India for a period of 6 months. The study involved positively flagged blood culture bottles that yielded single morphotype of Gram-negative organism by Gram stain. A total of 120 bacterial isolates were collected that consisted of consecutively obtained first 60 isolates of Enterobacteriaceae family (30 Escherichia coli and 30 Klebsiella pneumoniae ) and consecutively obtained first 60 nonfermenters (30 Pseudomonas aeruginosa and 30 Acinetobacter baumannii). Vitek-2 AST was done from these 120 blood culture broth, following the protocol by Biomerieux, and results were obtained. Then, Vitek-2 was done from colonies (reference method) using appropriate panel for Enterobacteriaceae and nonfermenters, and results were obtained. Both the results were compared. Results Nonfermenters showed a better categorical agreement of 97.6%, as compared to Enterobacteriaceae, which showed 97%. Among Enterobacteriaceae, both E. coli and K. pneumoniae showed categorical agreement of 97% each. Conclusion The procedure of AST directly from blood culture broth represents a simple and effective technique that can reduce the turnaround time by 24 hours, which in turn benefits the clinician in appropriate utilization of antimicrobials for better patient care. Thieme Medical and Scientific Publishers Pvt. Ltd. 2021-07-09 /pmc/articles/PMC8714412/ /pubmed/34975259 http://dx.doi.org/10.1055/s-0041-1732489 Text en The Indian Association of Laboratory Physicians. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Kavipriya, D
Prakash, Suman Susan
Dhandapani, Sarumathi
Rajshekar, Deepashree
Sastry, Apurba Sankar
Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title_full Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title_fullStr Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title_full_unstemmed Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title_short Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli
title_sort evaluation of the performance of direct susceptibility test by vitek-2 from positively flagged blood culture broth for gram-negative bacilli
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8714412/
https://www.ncbi.nlm.nih.gov/pubmed/34975259
http://dx.doi.org/10.1055/s-0041-1732489
work_keys_str_mv AT kavipriyad evaluationoftheperformanceofdirectsusceptibilitytestbyvitek2frompositivelyflaggedbloodculturebrothforgramnegativebacilli
AT prakashsumansusan evaluationoftheperformanceofdirectsusceptibilitytestbyvitek2frompositivelyflaggedbloodculturebrothforgramnegativebacilli
AT dhandapanisarumathi evaluationoftheperformanceofdirectsusceptibilitytestbyvitek2frompositivelyflaggedbloodculturebrothforgramnegativebacilli
AT rajshekardeepashree evaluationoftheperformanceofdirectsusceptibilitytestbyvitek2frompositivelyflaggedbloodculturebrothforgramnegativebacilli
AT sastryapurbasankar evaluationoftheperformanceofdirectsusceptibilitytestbyvitek2frompositivelyflaggedbloodculturebrothforgramnegativebacilli