Cargando…

Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System

The electrophysiological signal can reflect the basic activity of cardiomyocytes, which is often used to study the working mechanism of heart. Intracellular recording is a powerful technique for studying transmembrane potential, proving a favorable strategy for electrophysiological research. To obta...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhengjie, Xu, Dongxin, Fang, Jiaru, Xia, Qijian, Zhong, Wenxi, Li, Hongbo, Huang, Zhanyun, Cao, Nan, Liu, Xingxing, Chen, Hui-Jiuan, Hu, Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8714743/
https://www.ncbi.nlm.nih.gov/pubmed/34976989
http://dx.doi.org/10.3389/fbioe.2021.799312
_version_ 1784623972677058560
author Liu, Zhengjie
Xu, Dongxin
Fang, Jiaru
Xia, Qijian
Zhong, Wenxi
Li, Hongbo
Huang, Zhanyun
Cao, Nan
Liu, Xingxing
Chen, Hui-Jiuan
Hu, Ning
author_facet Liu, Zhengjie
Xu, Dongxin
Fang, Jiaru
Xia, Qijian
Zhong, Wenxi
Li, Hongbo
Huang, Zhanyun
Cao, Nan
Liu, Xingxing
Chen, Hui-Jiuan
Hu, Ning
author_sort Liu, Zhengjie
collection PubMed
description The electrophysiological signal can reflect the basic activity of cardiomyocytes, which is often used to study the working mechanism of heart. Intracellular recording is a powerful technique for studying transmembrane potential, proving a favorable strategy for electrophysiological research. To obtain high-quality and high-throughput intracellular electrical signals, an integrated electrical signal recording and electrical pulse regulating system based on nanopatterned microelectrode array (NPMEA) is developed in this work. Due to the large impedance of the electrode, a high-input impedance preamplifier is required. The high-frequency noise of the circuit and the baseline drift of the sensor are suppressed by a band-pass filter. After amplifying the signal, the data acquisition card (DAQ) is used to collect the signal. Meanwhile, the DAQ is utilized to generate pulses, achieving the electroporation of cells by NPMEA. Each channel uses a voltage follower to improve the pulse driving ability and isolates each electrode. The corresponding recording control software based on LabVIEW is developed to control the DAQ to collect, display and record electrical signals, and generate pulses. This integrated system can achieve high-throughput detection of intracellular electrical signals and provide a reliable recording tool for cell electro-physiological investigation.
format Online
Article
Text
id pubmed-8714743
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87147432021-12-30 Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System Liu, Zhengjie Xu, Dongxin Fang, Jiaru Xia, Qijian Zhong, Wenxi Li, Hongbo Huang, Zhanyun Cao, Nan Liu, Xingxing Chen, Hui-Jiuan Hu, Ning Front Bioeng Biotechnol Bioengineering and Biotechnology The electrophysiological signal can reflect the basic activity of cardiomyocytes, which is often used to study the working mechanism of heart. Intracellular recording is a powerful technique for studying transmembrane potential, proving a favorable strategy for electrophysiological research. To obtain high-quality and high-throughput intracellular electrical signals, an integrated electrical signal recording and electrical pulse regulating system based on nanopatterned microelectrode array (NPMEA) is developed in this work. Due to the large impedance of the electrode, a high-input impedance preamplifier is required. The high-frequency noise of the circuit and the baseline drift of the sensor are suppressed by a band-pass filter. After amplifying the signal, the data acquisition card (DAQ) is used to collect the signal. Meanwhile, the DAQ is utilized to generate pulses, achieving the electroporation of cells by NPMEA. Each channel uses a voltage follower to improve the pulse driving ability and isolates each electrode. The corresponding recording control software based on LabVIEW is developed to control the DAQ to collect, display and record electrical signals, and generate pulses. This integrated system can achieve high-throughput detection of intracellular electrical signals and provide a reliable recording tool for cell electro-physiological investigation. Frontiers Media S.A. 2021-12-15 /pmc/articles/PMC8714743/ /pubmed/34976989 http://dx.doi.org/10.3389/fbioe.2021.799312 Text en Copyright © 2021 Liu, Xu, Fang, Xia, Zhong, Li, Huang, Cao, Liu, Chen and Hu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Liu, Zhengjie
Xu, Dongxin
Fang, Jiaru
Xia, Qijian
Zhong, Wenxi
Li, Hongbo
Huang, Zhanyun
Cao, Nan
Liu, Xingxing
Chen, Hui-Jiuan
Hu, Ning
Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title_full Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title_fullStr Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title_full_unstemmed Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title_short Intracellular Recording of Cardiomyocytes by Integrated Electrical Signal Recording and Electrical Pulse Regulating System
title_sort intracellular recording of cardiomyocytes by integrated electrical signal recording and electrical pulse regulating system
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8714743/
https://www.ncbi.nlm.nih.gov/pubmed/34976989
http://dx.doi.org/10.3389/fbioe.2021.799312
work_keys_str_mv AT liuzhengjie intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT xudongxin intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT fangjiaru intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT xiaqijian intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT zhongwenxi intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT lihongbo intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT huangzhanyun intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT caonan intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT liuxingxing intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT chenhuijiuan intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem
AT huning intracellularrecordingofcardiomyocytesbyintegratedelectricalsignalrecordingandelectricalpulseregulatingsystem